R32 ATW Service Manual
19
7. Performance data
7.1 Heating capacity
LWE
Tamb
30
35
40
45
50
55
60
HC
PI
COP
HC
PI
COP
HC
PI
COP
HC
PI
COP
HC
PI
COP
HC
PI
COP
HC
PI
COP
-25/-
5.43
3.12 1.74
5.40
3.39 1.59
5.04
3.55 1.42
4.70
3.51 1.34
-20/-
7.28
3.01 2.41
7.20
3.19 2.26
6.08
3.02 2.01
5.64
3.09 1.82
5.10
3.54 1.44
-15/-
8.63
3.36 2.57
8.50
3.52 2.41
7.79
3.62 2.15
7.52
3.83 1.96
7.10
4.00 1.77
6.75
4.14 1.63
-7/-8
10.40 3.39 3.07
10.20 3.54 2.88
8.65
3.64 2.37
8.27
3.99 2.07
7.55
4.00 1.89
7.11
4.12 1.73
4.95 3.26 1.52
2/1
10.80 2.89 3.73
10.60 3.00 3.53
10.19 3.04 3.36
9.60
3.14 3.06
9.31
3.27 2.84
9.20
3.68 2.50
6.00 2.78 2.16
7/6
11.00 2.71 4.06
10.80 2.82 3.84
10.49 2.91 3.61
10.19 3.04 3.35
9.79
3.17 3.08
9.60
3.50 2.74
6.80 2.83 2.40
15/12
11.50 2.35 4.89
11.30 2.37 4.76
10.78 2.41 4.48
10.48 2.78 3.77
9.98
3.16 3.16
9.80
3.46 2.83
7.00 3.38 2.07
20/15
11.70 1.74 6.74
11.60 1.97 5.88
10.98 2.08 5.29
10.67 2.43 4.39
10.17 2.82 3.60
10.00 2.94 3.40
7.30 2.62 2.78
25/18
11.90 1.66 7.15
11.80 1.82 6.48
11.27 1.88 5.98
10.86 2.20 4.94
10.36 2.47 4.19
10.20 2.70 3.77
7.50 2.56 2.94
35/24
10.80 1.35 7.98
10.50 1.52 6.92
10.00 1.54 6.50
9.22
1.69 5.45
8.74
1.96 4.45
9.00
2.27 3.97
6.80 2.02 3.37
43/28
10.60 1.30 8.15
10.30 1.35 7.63
9.80
1.53 6.42
8.92
1.51 5.91
8.36
1.63 5.13
8.60
1.99 4.31
Integrated value takes into consideration the capacity drop during frosting and defrosting periods. The capacity is tested in free frequency situation.
Remark:
LWE: Leaving water temperature (
℃
);
Tamb: Ambient temperature(
℃
);
HC: Heating capacity (kW);
PI: Power input (kW)
2.86
2.25
1.27
3.78
2.98
1.27
/ FHOF-WHS-100CE3
FHIF-WHS-120CE3
Содержание FHIF-WHS-120CE3
Страница 2: ......
Страница 9: ...R32 ATW Service Manual 7 1 2 2 Hydronic module FHIF WHS 120CE3 FHIF WHS 160CE3...
Страница 18: ...R32 ATW Service Manual 16 Pic 4 3 Domestic hot water mode operation range...
Страница 23: ...R32 ATW Service Manual 21 8 System diagram...
Страница 24: ...R32 ATW Service Manual 22 9 Wiring diagram 9 1 Outdoor unit 9 1 1 9 1 2 FHOF WHS 100CE3 FHOF WHS 160CE3 3F...
Страница 28: ...R32 ATW Service Manual 26 Main PCB 3 Hydronic module Main PCB...
Страница 29: ...R32 ATW Service Manual 27 Filter board...
Страница 34: ...R32 ATW Service Manual 32 Model FHOF WHS 160CE3 3F...
Страница 35: ...R32 ATW Service Manual 33 Single unit installation More than one unit installation Unit mm...
Страница 46: ...R32 ATW Service Manual 44 HEATING MODE COOLING MODE...
Страница 47: ...R32 ATW Service Manual 45 HEATING MODE WITHOUT COOLING MODE DHW MODE WITHOUT COOLING MODE...
Страница 48: ...R32 ATW Service Manual 46 HEATING MODE WITHOUT DHW MODE AND DHW TANK ONLY DHW MODE...
Страница 56: ...R32 ATW Service Manual 54 When the unit has error code alarm port has a 220V output...
Страница 59: ...R32 ATW Service Manual 57...