Instruction Manual
D100392X012
EH Valves NPS 8 through 14
June 2017
3
Educational Services
For information on available courses for the Fisher EH NPS 8 through 14 valve, as well as a variety of other products,
contact:
Emerson Automation Solutions
Educational Services - Registration
Phone: 1-641-754-3771 or 1-800-338-8158
E-mail: [email protected]
emerson.com/fishervalvetraining
Table 3. Additional Shutoff Classification
Valve Design
(PRESSURE RATING)
Valve Size, NPS
Port Diameter, Inches
Cage Style
ANSI/FCI Leakage
Class
EHD
(CL1500)
8
10
7
Equal Percentage
Modified Equal Percentage
Linear (std. cage)
Linear (Whisper III, A1, B3, C3)
V with
optional Bore seal trim
EHD
(CL2500)
8
10
5.375
Equal Percentage, Modified Equal Percentage,
Linear (std. cage),
Linear (Whisper III, A1, B3, C3, D3)
V with
optional Bore seal trim)
12
14
7
Equal Percentage, Modified Equal Percentage,
Linear (std. cage),
Linear (Whisper III, A1, B3, C3, D3)
V with
optional Bore seal trim)
Table 4. Approximate Weights (Valve Body and Bonnet Assemblies)
VALVE
SIZE,
NPS
WEIGHTS
CL1500
CL2500
Buttwelding Ends
Flanged
Buttwelding Ends
Flanged
Kilograms
Pounds
Kilograms
Pounds
Kilograms
Pounds
Kilograms
Pounds
8
1400
3100
1700
3700
1900
4100
2200
4700
10
1500
3300
1900
4100
2000
4400
‐ ‐ ‐
‐ ‐ ‐
12
3400
7300
3900
8600
3400
7600
‐ ‐ ‐
‐ ‐ ‐
14
3400
7300
‐ ‐ ‐
‐ ‐ ‐
3400
7600
‐ ‐ ‐
‐ ‐ ‐
Installation
WARNING
Always wear protective gloves, clothing, and eyewear when performing any installation operations to avoid personal
injury.
To avoid personal injury or property damage resulting from the sudden release of pressure, do not install the valve
assembly where service conditions could exceed the limits given in this manual or on the appropriate nameplates. Use
pressure‐relieving devices as required by government or accepted industry codes and good engineering practices.
Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this
instruction manual.