background image

5.5 cu.ft. Undercounter Refrigerator

 Safety Precautions  |   3

Safety Precautions

All electrical appliances present some risk of injury. Your 
Isotemp refrigerator is designed to meet safety standards. 

Take care to carry and move your refrigerator with caution. Do 
not place it where it can fall, be dropped, or where the 
electrical connection can be submerged into water or other 
liquids.

There are no user-serviceable parts within the Isotemp 
5.5 cu.ft./156 L product.

Symbols used in this manual are described as follows:

Electrical Components 

Before installing, using or maintaining this product, be sure to 
read the manual and product warning labels carefully. Failure 
to follow these instructions may cause the product to 
malfunction, which could result in injury or damage.

If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the 
equipment off and on, you are encouraged to try to correct 
the interference by one or more of the following measures: 

Reorient or relocate the receiving antenna

Increase the separation between the equipment and 
receiver

Connect the equipment into an outlet on a circuit different 
from that to which the receiver is connected

Consult the dealer or an experienced radio/TV technician for 
help.

Refer to the section 

Unpacking the Isotemp 

Refrigerator

 section for details on handling and 

moving the unit

Used to indicate an electrical shock hazard.

Used when advice is given to prevent malfunction 
or injury.

Removal of the top cover for maintenance and 
other service should be performed only by factory 
authorized personnel.

CAUTION: 

For Class B - Unintentional 

Radiators: This device complies with Part 15 of 
the FCC Rules. Operation is subject to the 
following two conditions: (1) this device may not 
cause harmful interference and (2) this device 
must accept any interference received, including 
interference that may cause undesired operation.

WARNING: 

Hazardous voltages are present: To 

reduce the risk of electric shock and danger to 
personal health, follow the instructions provided 
in this manual.

CAUTION: 

ICES-003 Class B Notice—Avis 

NMB-003, Class B. This Class B digital apparatus 
complies with Canadian ICES–003.

Note: 

This equipment has been tested and found 

to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules. 
These limits are designed to provide reasonable 
protection against harmful interference in a 
residential installation. This equipment generates, 
uses and can radiate radio frequency energy and, 
if not installed and used in accordance with the 
instructions, may cause harmful interference to 
radio communications. However, there is no 
guarantee that interference will not occur in a 
particular installation.

WARNING: 

Hazardous voltages are present: To 

reduce the risk of electric shock DO NOT remove 
the rear cover on this product. There are no user 
serviceable parts inside. Services should be done 
by qualified personnel only.

WARNING: 

In order satisfy the FCC RF exposure 

limit for transmitting devices, a separation 
distance of 20 cm should be maintained between 
the body and the Isotemp refrigerator while in 
operation.

Содержание Isotemp Series

Страница 1: ...5 5 cu ft Undercounter Refrigerator Isotemp Series Installation and Operation 329153H01 Revision A April 2018...

Страница 2: ...ormed by qualified service personnel Material in this manual is for informational purposes only The contents and the product it describes are subject to change without notice Fisher Scientific makes n...

Страница 3: ...otemp Refrigerator 5 Inspecting for Damage 5 Unboxing and Locating 5 Identifying all Parts 5 Installation 6 Leveling 6 Intended Use 6 Providing Ventilation 6 Power On and Power Cord Guidelines 6 Unint...

Страница 4: ...roduct Interior 11 Navigating Isotemp 5 5 Cu Ft Refrigerator Controls 12 System Alerts 12 System Alert Values 12 Reading the LCD Temperature Display 12 Access the Main Menu 12 Maintenance 16 Frequentl...

Страница 5: ...to clean interior aluminum walls Internal Chamber Capacity 5 5 cu ft 156 L Chamber Temperature Uniformity 3 C 5 4 F from center air temperature Cooling System Refrigeration system with single 125W th...

Страница 6: ...certified by an EPA recognized certification body to use less energy and cause fewer emissions that contribute to climate change ENERGY STAR and the ENERGY STAR mark are registered trademarks owned b...

Страница 7: ...function or injury Removal of the top cover for maintenance and other service should be performed only by factory authorized personnel CAUTION For Class B Unintentional Radiators This device complies...

Страница 8: ...Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including in...

Страница 9: ...our new product safely and easily Unboxing and Locating We recommend you move the box as close as possible to its final location before you begin to unpack This unit is not provided with handles there...

Страница 10: ...er refrigerator is equipped with a ventilation area just above the door handle Do not block or cover the venting area as this can impact the performance of the refrigerator Power On and Power Cord Gui...

Страница 11: ...wer source fails If you use a UPS backup take care to follow the directions and precautions accompanying that device Be careful not to plug into a wall outlet controlled by a wall switch to avoid acci...

Страница 12: ...run and the refrigerator will work to reach the default set point temperature Once set point is reached the fan speed will reduce to conserve energy The unit will reach air temperature setting rapidly...

Страница 13: ...s Avoid storing beverages or any non sample items like food in any unit used for sensitive inventory Not only is this a health hazard it also leads to more frequent opening of the door Note Isotemp un...

Страница 14: ...battery serves to support alerting the user in the event of a power loss Ventilation The Isotemp refrigeration system is a solid state system utilizing fans with moving parts The functioning of the f...

Страница 15: ...g and flush as possible to insulate against cooling loss Putty may also be used to help reseal the area Evaporation Tray The evaporation tray is located on the bottom rear of the unit Product Interior...

Страница 16: ...ator Controls 5 5 cu ft Undercounter Refrigerator Navigating Isotemp 5 5 Cu Ft Refrigerator Controls System Alerts System Alert Values Reading the LCD Temperature Display Access the Main Menu Color Di...

Страница 17: ...een that lists each alarm triggered Alarm Log The Alarm Log screen displays a history of all alarms Alarm Settings The Alarm Settings menu allows you to Select the high and low temperature alarms It a...

Страница 18: ...s the ability to coordinate the results of a third party external NIST calibrated reference thermometer with the temp displayed on the refrigerator Example Refrigerator air temperature displays as 3 5...

Страница 19: ...Cu Ft Refrigerator Controls 15 Model Information This displays the model number UI FW version UI FW date and TEC FW version of your unit System Information This displays the current settings which inc...

Страница 20: ...attachment Note Do not remove the top cover Do not attempt to clean the power supply located below the fan assembly You could damage your unit Cleaning the Condensate Tray The condensate tray is foun...

Страница 21: ...ontinuous power to the audible and visual alerts of power loss How long before I can use the product In a normal ambient environment your refrigerator should pull down to the target set point within a...

Страница 22: ...oor alarm keeps sounding Check to make sure the door is properly aligned in the frame by looking for uneven surfaces For example is the gap from the hinge to edge equal in width all the way across the...

Страница 23: ...shall apply only if Fisher Scientific verifies the applicable defect upon examination 5 Any defects or other damages resulting from shipment of the unit are not covered by this warranty Fisher Scienti...

Страница 24: ...verr smaltito o riciclato tramite queste medesime Ulteriori informazioni sulla conformit di Fisher Scientific con queste Direttive l elenco delle ditte di riciclaggio nel Vostro paese e informazioni...

Страница 25: ...sher com Italie 39 02 950 59 478 it fishersci com 39 800 823 162 unity it thermofisher com Finlande 358 0 9 8027 6280 fishersci fi 46 8 556 468 20 unity fi thermofisher com France 33 0 3 88 67 14 14 f...

Страница 26: ...Road Asheville NC 28804 United States Find out more at fishersci com 2018 Fisher Scientific Inc All rights reserved All trademarks are the property of Fisher Scientific and its subsidiaries unless oth...

Отзывы: