![Fisher & Paykel WL26CW1 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/fisher-and-paykel/wl26cw1/wl26cw1_service-supplement-manual_2296449019.webp)
517794B
19
8.3 SLR
Feature
SLR Feature stands for Simplified Leak
Recirculation. This feature has been added so
that should the flapper not completely seal
against the housing of the pump when draining,
water can bypass through this hole and back
into the pump, avoiding recirculating back into
the bowl and on to the clothes load.
It is important that this hole remains clear, and it
should be checked whenever the pump is
serviced.
8.4
Testing the Stator
SmartPump™ Wiring Diagram
The stator resistance can either be tested from the harness to the motor controller or at the
connections to the stator itself.
8.4.1
Testing SmartPump™ Stator From The Console
The resistance of each individual winding is
approximately 8.1
Ω
+/- 10%, however when
testing the stator from the console we are
testing across two windings, therefore the
resistance should be approximately 16.2
Ω
+/-
10%.
To test all windings you will need to measure
across:
• Red and White
• Blue and White
• Blue and Red
BLUE
RED
WHITE
16.2
Ω
16.2
Ω
16.2
Ω
8.1
Ω
8.1
Ω
8.1
Ω