background image

B E F O R E   Y O U   S TA R T

PAGE 2 OF 8

USA

I N S T A L L A T I O N   I N F O R M A T I O N

AEROTECH   BUILT - IN OVENS

OS301 / OD301 SERIES

Correct installation is the responsibility of the customer. 
Ensure that the installer is properly qualified to install this oven.

Make sure that the oven is located away from any strong and/or hot drafts of air.

The cabinet opening dimensions specified are the absolute minimum.  These dimensions allow a clearance 

of up to 

1

/

4

” (6mm).

The product must be electrically grounded. See “Electrical Connection” for details.

We recommend that the electrical supply junction box is located either 3’’ below the main support surface of 

the product on the right hand side or flush mounted in the rear wall behind the product or mounted in the 
adjacent right-hand side cabinet.  A 1” diameter hole should be drilled in the right rear corner of the oven 
cabinet or in the rear of the right-hand side wall as required to enable the electrical supply cord to be passed 
through the cabinet to the junction box.  Details of these requirements are shown in the diagram to the right.

The oven support surface should be flat, level and be able to support a weight of at least 420 pounds (190 Kg) 

for a double oven and 238 pounds (108 Kg) for single oven models. 

You will need a No.2 Phillips screwdriver to complete the installation of the oven into the cabinet. 

There should be 4 suitable wood screws with this installation kit (Part number 556075) and 4 spacers 
(Part number 545455).

Fisher & Paykel CE901 cooktop can be installed above an OS301 single wall oven if a 

3

/

8

” (10mm) gap is 

provided between the top of the oven and the bottom of the cooktop.

Junction Box 
location for
undercounter
installation

Junction Box
location for wall
installation

It is the customers responsibility:

It is the customers responsibility to ensure that the product is electrically connected by a qualified

electrical installer in conformance with the National Electrical code, ANSI/NFPA 70 (latest edition) and
all local codes and ordinances. 

Copies of the standards listed may be obtained from 
* National Fire Protection Association
Batterymarch Park, Quincy, Massachusetts 02269

PAGE 1 OF 8

P/N  545855C

DATE OF ISSUE

September 2002

I M P O R TA N T   -   S AV E F O R T H E L O C A L E L E C T R I C A L I N S P E C T O R ’ S U S E

Содержание OS301

Страница 1: ...ed See Electrical Connection for details We recommend that the electrical supply junction box is located either 3 below the main support surface of the product on the right hand side or flush mounted in the rear wall behind the product or mounted in the adjacent right hand side cabinet A 1 diameter hole should be drilled in the right rear corner of the oven cabinet or in the rear of the right hand...

Страница 2: ...tion box Details of these requirements are shown in the diagram to the right The oven support surface should be flat level and be able to support a weight of at least 420 pounds 190 Kg for a double oven and 238 pounds 108 Kg for single oven models You will need a No 2 Phillips screwdriver to complete the installation of the oven into the cabinet There should be 4 suitable wood screws with this ins...

Страница 3: ...ONS PROUD DIMENSIONS Oven Door 21 5 8 550mm 22 1 2 570mm 27 1 16 688mm 26 9 16 675mm 29 3 4 757mm 28 1 4 718mm 29 3 4 757mm 28 1 4 718mm Oven Door 21 5 8 550mm 22 1 2 570mm 48 7 16 1230mm 47 15 16 1217mm TOP VIEW RECESSED DIMENSIONS TOP VIEW ...

Страница 4: ...abinet Width Minimum Distance Under Benchtop for Single 2 3 4 70mm 22 5 8 573mm Inside Cabinet Depth RECESSED DIMENSIONS TOP VIEW 26 13 16 681mm Single 47 1 8 1222mm Double Inside Cabinet Height 28 1 2 724mm Inside Cabinet Width Minimum Distance Under Benchtop for Single ovens 2 3 4 70mm 27 5 16 693mm Single 48 5 8 1235mm Double Recess Height 30 762mm Recess Width 24 610mm Inside Cabinet Depth 5 1...

Страница 5: ...binet Make the electrical connection following the steps appropriate for your installation 1 Disconnect the power supply WARNING Failure to disconnect the power supply may result in death or injury 2 Remove the junction box cover 3 Connect the oven cable to the junction box through the U L listed conduit connector 4 Connect the two black wires together with twist on connectors 5 Connect the two re...

Страница 6: ...cal codes PERMIT connecting cabinet grounding conductor to neutral white wire in the junction box 7 Connect the factory crimped green and white oven cable wires to the neutral white wire in the junction box 8 Replace the junction box cover If local codes DO NOT PERMIT connecting cabinet grounding conductor to neutral white wire in junction box 7 Separate the factory crimped green and white oven ca...

Страница 7: ...h upper hinge arms in the top slots and both lower hinge arms in the lower slots Push the hinges as far as they will go until the slot in the lower arm locates in the hinge support Lower the door gently Push the catches away from you off the hooks Make sure that they disengage properly Raise the door slightly and ensure the catches are released from the hooks The door can now be closed WARNING Do ...

Страница 8: ...Call your local Customer Care representative on 1 8889 FNP USA 1 8889 367 872 Please have the model and serial number of your product ready for the Customer Care representative 1 Make sure product is level and securely fitted to the cabinetry and both oven doors open and close freely 2 Make sure all the internal packaging has been removed from the oven cavity 3 Make sure all oven vents and opening...

Отзывы: