B E F O R E Y O U S TA R T
PAGE 2 OF 8
USA
I N S T A L L A T I O N I N F O R M A T I O N
AEROTECH BUILT - IN OVENS
OS301 / OD301 SERIES
Correct installation is the responsibility of the customer.
Ensure that the installer is properly qualified to install this oven.
Make sure that the oven is located away from any strong and/or hot drafts of air.
The cabinet opening dimensions specified are the absolute minimum. These dimensions allow a clearance
of up to
1
/
4
” (6mm).
The product must be electrically grounded. See “Electrical Connection” for details.
We recommend that the electrical supply junction box is located either 3’’ below the main support surface of
the product on the right hand side or flush mounted in the rear wall behind the product or mounted in the
adjacent right-hand side cabinet. A 1” diameter hole should be drilled in the right rear corner of the oven
cabinet or in the rear of the right-hand side wall as required to enable the electrical supply cord to be passed
through the cabinet to the junction box. Details of these requirements are shown in the diagram to the right.
The oven support surface should be flat, level and be able to support a weight of at least 420 pounds (190 Kg)
for a double oven and 238 pounds (108 Kg) for single oven models.
You will need a No.2 Phillips screwdriver to complete the installation of the oven into the cabinet.
There should be 4 suitable wood screws with this installation kit (Part number 556075) and 4 spacers
(Part number 545455).
A Fisher & Paykel CE901 cooktop can be installed above an OS301 single wall oven if a
3
/
8
” (10mm) gap is
provided between the top of the oven and the bottom of the cooktop.
Junction Box
location for
undercounter
installation
Junction Box
location for wall
installation
It is the customers responsibility:
It is the customers responsibility to ensure that the product is electrically connected by a qualified
electrical installer in conformance with the National Electrical code, ANSI/NFPA 70 (latest edition) and
all local codes and ordinances.
Copies of the standards listed may be obtained from
* National Fire Protection Association
Batterymarch Park, Quincy, Massachusetts 02269
PAGE 1 OF 8
P/N 545855C
DATE OF ISSUE
September 2002
I M P O R TA N T - S AV E F O R T H E L O C A L E L E C T R I C A L I N S P E C T O R ’ S U S E