CONNECT THE OVEN TO THE MAINS SUPPLY

If local codes permit connecting the cabinet-grounding 
conductor to the neutral (white) wire in the junction box

Disconnect the power supply.

Remove the junction box cover.

Connect the oven cable to the junction box through 
the U.L.-listed conduit connector.

Connect the two black wires together with twist-on 
connectors.

Connect the two red wires together with twist-on 
connectors.  

Connect electrical connection according to local 
codes and ordinances.

Connect the factory-taped green and white oven 
cable wires to the neutral (white) wire in the junction 
box.

Replace the junction box cover.

Four-wire electrical system

Disconnect the power supply.

Remove the junction box cover.

Connect the oven cable to the junction box through the U.L.-listed conduit connector.

Connect the two black wires together with twist-on connectors.

Connect the two red wires together with twist-on connectors.  

Connect electrical connection according to local codes and ordinances.

Separate the green and white oven cable wires.

Connect the white oven cable wire to the neutral (white) wire in junction box.

Connect the green grounding oven cable wire to the (green) grounding wire in the junction box. Do not connect the green 
grounding wire to the neutral (white) wire in junction box

!0 

Replace the junction box cover.

If local codes DO NOT PERMIT connecting the cabinet-grounding 
conductor to the neutral (white) wire in junction box

Disconnect the power supply.

Remove the junction box cover.

Connect the oven cable to the junction box through the U.L.-
listed conduit connector.

Connect the two black wires together with twist-on connectors.

Connect the two red wires together with twist-on connectors.  

Connect electrical connection according to local codes and 
ordinances.

Separate the factory-taped green and white oven cable wires.

Connect the white oven cable wire to the neutral (white) wire 
in junction box.

Connect the green grounding oven cable wire to a grounded 
wire in the junction box.

!0 

Replace the junction box cover.

Connection methods

Junction box locations

Nameplate location

OB24SDPT MODELS

VOLTAGE

MAX. CURRENT DRAW

MAX LOAD

208 V

16.6 A

3.5 kW

240 V

19.4 A

4.6 kW

a

B

cable from 
power supply

junction box 
location for 
undercounter 
installation

junction box 
location for 
wall installation

cable from 
power supply

box

black 
wires

black 
wires

red 
wires

red 
wires

green grounding 
oven wires - 
factory taped

white 
wires

white and green 
grounding oven 
wires - factory 
taped

U.L.-listed 
conduit 
connector

U.L.-listed 
conduit 
connector

box

Содержание OB24SDPT

Страница 1: ...OB24SDPT models BUILT IN OVEN INSTALLATION GUIDE US CA 591944A 07 19 ...

Страница 2: ... the mains power supply only by a suitably qualified person according to these installation instructions and in compliance with any applicable local building and electricity regulations Failure to install the appliance correctly could invalidate any warranty or liability claims z z If the power supply cable is damaged it must be replaced by the manufacturer its service agent or similarly qualified...

Страница 3: ...thorities and by laws if in doubt regarding installation IMPORTANT Some environmental factors and cooking habits can cause condensation in and around the oven during use To protect surrounding cabinetry from possible damage caused by frequent or excessive condensation we recommend moisture proofing the oven cavity Ensure that z z the oven door can open fully without obstruction z z the oven is not...

Страница 4: ...s 22 1 4 565 D Height of chassis 22 5 8 575 E Width of chassis 21 7 8 556 F Depth of chassis 21 7 16 545 G Depth of oven frame and control panel distance between front of chassis and front of oven door excl handle and dials 13 16 20 H Depth of oven door when fully open measured from front of control panel 18 1 8 460 PRODUCT DIMENSIONS a c f g d b e h FRONT PLAN PROFILE ...

Страница 5: ...ght of cavity 22 13 16 580 D Overall height of cabinetry 23 5 8 600 E Minimum inside depth of cavity 21 5 8 550 If installing a cooktop above the oven ensure adequate clearance is provided as per the cooktop manufacturer s instructions CABINETRY DIMENSIONS PROFILE PLAN d c e b a PROUD INSTALL FLUSH INSTALL 5 8 13 16 16 20mm 5 8 13 16 16 20mm min 1 16 2mm ...

Страница 6: ...6 Remove the accessories box from the top of the oven and set aside Recycle responsibly DISCARD PACKAGING RESPONSIBLY ...

Страница 7: ...e green grounding wire in the junction box Do not connect the green grounding wire to the neutral white wire in junction box 0 Replace the junction box cover If local codes DO NOT PERMIT connecting the cabinet grounding conductor to the neutral white wire in junction box 1 Disconnect the power supply 2 Remove the junction box cover 3 Connect the oven cable to the junction box through the U L liste...

Страница 8: ...ven into the cabinetry with silicone or glue This makes future servicing difficult Fisher Paykel will not cover the costs of removing the oven or of damage caused by this removal 1 Position the oven in the prepared cavity 2 Open the oven door fully 3 Mark and pre drill the screw holes 4 Use the supplied screws to secure the oven to the cabinetry ...

Страница 9: ...and free of any obstruction or damage IMPORTANT Failure to make sure all oven vents are clear may result in poor product performance Ensure the isolating switch is accessible by the customer TEST OPERATION Turn the power to the oven on The display should light up Set the clock following the instructions in the User guide Set the oven to Bake at 50o C The light should come on inside the oven cavity...

Страница 10: ...nt apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at any time You should therefore check with your Dealer to ensure this booklet correctly describes the product currently available US CA 591944A 07 19 ...

Страница 11: ...Modèles OB24SDPT FOUR ENCASTRÉ GUIDE D INSTALLATION CA 591944A 07 19 ...

Страница 12: ...ez le four en utilisant uniquement du fil de cuivre z z Ne coupez pas le conduit z z Un connecteur de conduit homologué U L doit être disponible au niveau de la boîte de jonction z z Ne reliez pas la mise à la terre à une conduite de gaz z z N installez aucun fusible dans le circuit neutre ou de mise à la terre z z Installez un fusible aux deux extrémités du câble électrique z z Nous vous recomman...

Страница 13: ...r et à proximité du four pendant l utilisation Pour protéger les armoires à proximité des dommages pouvant être causés par une condensation fréquente ou excessive nous vous recommandons d utiliser un matériau résistant à l humidité dans la cavité du four Assurez vous que z z la porte du four peut s ouvrir complètement sans obstruction z z ne scellez pas le four dans les armoires avec de la silicon...

Страница 14: ...es boutons 22 1 4 565 D Hauteur du châssis 22 5 8 575 E Largeur du châssis 21 7 8 556 F Profondeur du châssis 21 7 16 545 G Profondeur du cadre de four et du panneau de commande distance entre le devant du châssis et le devant de la porte du four excl les boutons 13 16 20 H Profondeur de la porte entièrement ouverte mesurée depuis le devant du panneau de commande 18 1 8 460 a c f g d b e h DE FACE...

Страница 15: ...intérieure minimale de la cavité 21 1 16 560 B Largeur hors tout des armoires 23 5 8 600 C Hauteur intérieure minimale de la cavité 22 13 16 580 D Hauteur hors tout des armoires 23 5 8 600 E Profondeur intérieure minimale de la cavité 21 5 8 550 Si une surface de cuisson doit être installée au dessus du four prévoyez un dégagement suffisant pour la surface de cuisson conformément aux instructions ...

Страница 16: ...6 Retirez la boîte d accessoires du dessus du four et mettez la de côté Recyclez de manière responsable METTEZ L EMBALLAGE AU REBUT DE MANIÈRE RESPONSABLE ...

Страница 17: ...e vert dans la boîte de jonction Ne connectez pas le fil de mise à la terre vert au fil neutre blanc dans la boîte de jonction 0 Remettez le couvercle de la boîte de jonction en place Si les codes locaux NE PERMETTENT PAS de raccorder le conducteur de mise à la terre du bâti au fil neutre blanc dans la boîte de jonction 1 Débranchez l alimentation électrique 2 Retirez le couvercle de la boîte de j...

Страница 18: ... avec de la silicone ou de la colle Cela rendrait difficile tout travail d entretien futur Fisher Paykel n assumera pas les frais liés au retrait du four ou aux dommages causés par ce retrait 1 Positionnez le four dans la cavité préparée 2 Ouvrez complètement la porte du four 3 Marquez et pré percez les trous de vis 4 Utilisez les vis fournies pour fixer le four aux armoires ...

Страница 19: ...xempts de tout dommage ou obstruction IMPORTANT Le fait de ne pas vérifier que tous les évents du four sont dégagés peut compromettre le fonctionnement du produit Assurez vous que le client peut accéder à l interrupteur de sectionnement FAITES UN ESSAI Activez l alimentation du four L afficheur doit s allumer Réglez l horloge en suivant les instructions dans le Guide d utilisation Réglez le four à...

Страница 20: ... livret s appliquent aux modèles et produits spécifiques qui y sont décrits à la date de publication Dans le cadre de notre politique d amélioration en permanence de nos produits ces caractéristiques peuvent être modifiées à tout moment Nous vous recommandons de vérifier auprès de votre détaillant que ce livret décrit le produit actuellement disponible ...

Отзывы: