5
A
B
INSTALLATION HEIGHT
ATTACHMENT DIMENSIONS
ATTACHMENT DIMENSIONS
MM
A
Lower rangehood attachment point width
508
B
Lower rangehood attachment point height
47
C
Upper rangehood attachment point width
250
D
Upper rangehood attachment point height
294
E
Chimney bracket attachment point width
250
F
Chimney bracket attachment point height
596
G
Upper chimney bracket attachment point width
250
H
Upper chimney bracket attachment point height
25
HEIGHT DIMENSIONS
MM
A
Ducted installation
z
Minimum height
z
Maximum height
636
975
Recirculation
z
Minimum height
z
Maximum height
676
975
B
Height from top of cooktop to base of product
650 – 750
This rangehood must be installed no lower than the minimum height indicated in the table
above. Minimum installation height may be greater if required by the cooktop, refer to your
cooktop installation instructions.
Installation at the minimum height will improve the efficiency of capturing cooking odours,
grease and smoke. Installation above the minimum height is the users preference, it is not
recommended to install above the maximum height indicated in the table above.
A
H
F
D
B
C
E
G
Upper chimney bracket
attachment points
Chimney bracket
attachment points
Upper rangehood hood
attachment points
Lower rangehood
attachment points