Fisher & Paykel HC120BCXB2 Скачать руководство пользователя страница 25

23

CuSTOMER CaRE

Before you call for service or assistance...

Check the things you can do yourself. Refer to your user guide and check that:

1

  Your product is correctly installed.

2

  You are familiar with its normal operation.

If after checking these points you still need assistance or parts, please refer to your 
nearest Authorised Service Centre, Customer Care, or contact us through our local 
website listed on the back cover.

In united kingdom if you need assistance…*

Call the Fisher & Paykel Customer Care Centre and talk to one of our Customer 
Care Consultants.

Phone:

 08000 886 605

fax:

 08000 886 606

website:

 www.fisherpaykel.com

Postal address:

 Fisher & Paykel Appliances Ltd, Maidstone Road, Kingston, 

Milton Keynes, Buckinghamshire, MK10 0BD

In Ireland if you need assistance…*

Phone:

 1800 625 174 or 01-8077960

fax:

 1800 635 012

website:

 www.fisherpaykel.com

Postal address:

 Fisher & Paykel Appliances, Unit D2, North Dublin Corporate Park, 

Swords, Co. Dublin

*If you call, write or contact our website please provide: your name and address, model 
number, serial number, date of purchase and a complete description of the problem. 
This information is needed in order to better respond to your request for assistance.

Product details can be found on the easy clean plate underneath the filters.

Registration

Register your product with us so we can provide you with the best service possible.  
To register your product visit our website: 

www.fisherpaykel.com

Содержание HC120BCXB2

Страница 1: ...Box wall cooker hood HC60BCXB2 HC90BCXB2 and HC120BCXB2 models GB IE INSTALLATION INSTRUCTIONS USER GUIDE...

Страница 2: ......

Страница 3: ...THESE INSTRUCTIONS The models shown in this user guide may not be available in all markets and are subject to change at any time For current details about model and specification availability in your...

Страница 4: ......

Страница 5: ...ith you This use and care manual will answer most of your questions about the set up use and on going maintenance of your Fisher Paykel product however if you require further information about your pr...

Страница 6: ...any maintenance or repairs Alterations to the domestic wiring system must only be made by a qualified electrician Failure to follow this advice may result in electrical shock or death IMPORTANT SAFET...

Страница 7: ...top of the cooker hood with cardboard or polystyrene during the installation to minimise the risk of damage occurring To reduce the risk of damage occurring to the hob it is recommended that the surf...

Страница 8: ...out supervision You must read the details concerning the method and frequency of cleaning There is a fire risk if cleaning is not carried out in accordance with the instructions Never leave frying foo...

Страница 9: ...tructions User guide manual 1 Chimney 1 Expansion plug 8 30 mm self tapping screw 8 Upper chimney 1 Cooker hood 1 Ducting adapter 150 mm 1 Chimney bracket 1 Box wall cooker hood HC60BCXB2 HC90BCXB2 an...

Страница 10: ...8 INSTALLATION INSTRUCTIONS Product dimensions G F B A max A min E D K L C I H Power cord location J...

Страница 11: ...nless strip 27 27 27 F Width of flue 320 320 320 G Depth of flue 290 290 290 H Distance from centre of ducting outlet to back of product 105 105 105 I Distance from centre of ducting outlet to side of...

Страница 12: ...ONS Height of cooker hood N M installation dimensions mm M Installation height Ducted Recirculation min 635 max 1035 min 675 max 1035 N Height top of hob to base of product Electric hob Gas hob min 60...

Страница 13: ...d be taken to position the hole correctly For optimal efficiency use rigid or semi rigid ducting for reduced noise and increased airflow Flexible ducting should only be used as a last resort ie in dif...

Страница 14: ...sily damaged during installation if grazed or knocked by tools Please take care to protect the surfaces during installation Protect the hob surface below with cardboard or the like to prevent damage o...

Страница 15: ...B 250 mm 235 mm C D Upper chimney extension bracket attachment points Chimney bracket attachment points Upper hood attachment points Lower hood attachment points HC60BCXB2 HC90BCXB2 HC120BCXB2 mm A 42...

Страница 16: ...14 INSTALLATION INSTRUCTIONS Fig 3 3 Attach ducting adapter Place the ducting adapter onto the hood and screw it in place using the 10 mm screws...

Страница 17: ...15 INSTALLATION INSTRUCTIONS 4 Attach hood to wall Remove filters and easy clean plate from hood as shown in Fig 4 Fig 4...

Страница 18: ...hten screws Attach lower hood mounting screws to fix hood to wall Reattach easy clean plate and filters 5 Attach ducting Attach ducting to ducting adapter and vent outside 6 Attach chimney Place chimn...

Страница 19: ...Efficiency Class A Grease Filtering Efficiency 91 2 Grease Filtering Efficiency Class B Airflow at Min Speed m hr 200 Airflow at Max Speed m hr 525 Airflow at Boost Speed m hr 710 Airborne noise at m...

Страница 20: ...he timer on The fan operates for 5 minutes at the current speed and each descending speed before turning off The timer icon flashes red when the filters need cleaning To reset the timer press the butt...

Страница 21: ...humidity or coastal environments cleaning should be carried out more frequently Aluminium filters Depending on use and at least once a month the aluminium grease filters should be removed and cleaned...

Страница 22: ...is used Note fully saturated carbon filters can become a barrier to air movement therefore limiting cooker hood performance In the event of fire grease laden filters could be flammable and therefore r...

Страница 23: ...s and accessories item reference number LED bulb x2 792556 Aluminium filter 791938 Recirculation carbon filter 50031 Recirculation diverter 50032 Ducting kit 150 mm eaves 50033 Ducting kit 150 mm wall...

Страница 24: ...ats cockroaches etc 7 Replacement light bulbs B Defects caused by factors other than 1 Normal domestic use or 2 Use in accordance with the product s user guide C Defects to the product caused by accid...

Страница 25: ...paykel com Postal address Fisher Paykel Appliances Ltd Maidstone Road Kingston Milton Keynes Buckinghamshire MK10 0BD In Ireland if you need assistance Phone 1800 625 174 or 01 8077960 Fax 1800 635 01...

Страница 26: ...24 customer care Complete and keep for safe reference Model Serial No Purchase Date Purchaser Dealer Suburb Town Country...

Страница 27: ......

Страница 28: ...s in this booklet apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at any time You should the...

Отзывы: