Electrical requirements
Use only a Ground Fault Interrupter (GFI) protected circuit with
this product.
An outdoor 120VAC 15A GFI electrical outlet should be installed
by a qualified electrician either inside the island enclosure for
built-in units, or near the location where a free-standing unit
will be used. For built-in products, the supplied 12V transformer
should be connected during installation.
Installation
The transformer must be secured below the product in a dry
location away from any excessive heat. Be sure to provide
adequate access to facilitate service if the transformer or
connections require maintenance.
All units are supplied with a 12V power transformer to operate the
products ignition and dial illumination features. The transformer is
sealed in a box with an attached power supply cord.
ELECTRICAL CONNECTION
TO OUTLET
Dial halos
When a dial is in use, an orange halo around that dial will
illuminate. This will change from orange to white if the dial is
turned to
OFF
but another dial remains active. If all dials are
turned
OFF
, all halos will dim.
Multiple DCS Series 9 products may be linked together to allow
for cross-product halo illumination. To allow for this functionality,
an approved DCS kit is required and can be
purchased separately
from your local DCS dealer.
If the ignition or dial halos fail to operate, a connection may
have come loose during installation or the GFI may have tripped
requiring a reset. Refer to the troubleshooting section of your
user guide for further guidance.