Fisher & Paykel BI451 Series Скачать руководство пользователя страница 1

Page 1

 

IMPORTANT!

 

PLEASE MAKE THIS INFORMATION AVAILABLE TO YOUR JOINER AS IT

 COULD REDUCE YOUR INSTALLATION COST.

Fisher & Paykel

INSTALLATION INFORMATION

Built-In Ovens

BI601 Series - Built-In Oven

BI601D Series - Built-In Double Oven

BI601XC2 Series - Built-In Oven/Microwave Combination

BI451 Series - Built-In Compact Oven

CAUTION: In order to avoid a hazard these appliances must be installed

according to these Installation Instructions.

Please follow installation information carefully.

If in doubt consult your local building authority by-laws.

BEFORE YOU START

DO

Ensure a suitable disconnection switch is incorporated in the permanent wiring,

mounted and positioned to comply with the local wiring Rules and Regulations.

DO

Ensure that the location of the Oven connection socket is outside the installation

space if the appliance is flush to the rear wall.

DO

Ensure the benchtop and the Oven cavity are square and level.

DO

Ensure the electrician allows as least 1.5m free length of connection cable within the

cavity for ease of installation and service of the Oven.

DO

Use easy to clean finishes for the wall surfaces surrounding the Oven and Cooktop to

aid removal of any cooking fume staining resulting from use of the Oven and

Cooktop.

DO

Ensure that the interconnection cord between the Cooktop and the Oven is not

accessible via cupboard doors after installation.  This applies to any extension cords as

well, even though they are double insulated.

DO

Consult local building authorities and by-laws if in doubt regarding installation.

DO

Check the height from the floor suits the user.

DO

Ensure the cavity is a completely sealed box with no gaps.  This will ensure the

cooling air flows under the product to give the correct venting and cooling for the

oven and cabinet  surround.

Содержание BI451 Series

Страница 1: ...the installation space if the appliance is flush to the rear wall DO Ensure the benchtop and the Oven cavity are square and level DO Ensure the electrician allows as least 1 5m free length of connection cable within the cavity for ease of installation and service of the Oven DO Use easy to clean finishes for the wall surfaces surrounding the Oven and Cooktop to aid removal of any cooking fume stai...

Страница 2: ... in the kitchen unit 4 When installing the oven it is essential to centre the product in the cavity giving a spacing of 2 5mm from the door edge to the joinery NOTE If installing a Cooktop above the Oven ensure adequate clearance is provided for the Cooktop as per the Cooktop Manufacturer s Instructions If installing a BI601 Single Built In Oven with Wall Trim Kit ensure you use instructions that ...

Страница 3: ...Page 3 Height Recommendation Guide Figures are based on an average height of 1650mm 5 5 wearing shoes The height of the product may vary 50mm according to the height of the most frequent user ...

Страница 4: ...Built In Oven Overall Overall Width Height Depth Oven Dimensions 595mm 595mm 562mm Cabinet Dimensions 568mm 585mm 550mm Please Note Oven front dimensions differ from cabinet dimensions Top View Side View Product Dimensions ...

Страница 5: ...lt In Double Oven Overall Overall Width Height Depth Oven Dimensions 595mm 932mm 562mm Cabinet Dimensions 568mm 922mm 550mm Please Note Oven front dimensions differ from cabinet dimensions Product Dimensions Top View Side View ...

Страница 6: ...ave Combination Overall Overall Width Height Depth Oven Dimensions 595mm 932mm 562mm Cabinet Dimensions 568mm 935mm 550mm Please Note Oven front dimensions differ from cabinet dimensions Product Dimensions Top View Side View Cabinet Detail View ...

Страница 7: ...ave Combination Overall Overall Width Height Depth Oven Dimensions 595mm 932mm 562mm Cabinet Dimensions 568mm 935mm 550mm Please Note Oven front dimensions differ from cabinet dimensions Product Dimensions Top View Side View Cabinet Detail View ...

Страница 8: ...t In Compact Oven Overall Overall Width Height Depth Oven Dimensions 595mm 450mm 562mm Cabinet Dimensions 568mm 440mm 550mm Please Note Oven front dimensions differ from cabinet dimensions Product Dimensions Top View Side View ...

Страница 9: ...Part No 540784C August 2001 ...

Страница 10: ...d removal of any cooking fume staining resulting from use of the Cooktop DO Consult local building authorities and by laws if in doubt regarding installation DO Ensure that the interconnection cord between the Cooktop and the Oven or control Box is not accessible via cupboard doors after installation This applies to any extension cord as well even though they are double insulated Note Ensure that ...

Страница 11: ...n the cutout Feed the cooktop wiring harness up through the box cutout Remove Control Box cover Connect the cooktop wiring harness Clamp the wiring harness Wire the mains to the box and clamp Replace Control box cover Roll the box into the cutout Secure control box and cooktop using brackets provided Note Two small brackets are provided that screw to the sides of the control box These must be used...