FISCHER Mess- und Regeltechnik GMBH
Technical Data | 5
BA_EN_ME11
15/24
5.3 Output parameters
2-Conductor
3-Conductor
Output signal
4 … 20 mA DC
0 … 10 V DC
Limits
Max. 21 mA
Max. 10.5 V
Apparent ohmic resist-
ance
(U
b
-6V)/0.02A
U
b
≥ 15V
≥ 5kΩ
U
b
≥ 20V
≥ 2kΩ
5.4 Measurement accuracy
Non-linearity
< 1.0 % FS
Hysteresis
< 0.5 % FS
Characteristic curve deviation
*)
1.0 %
Temperature drift
Zero point
0.07 % FS/K
Measuring range
0.05 % FS/K
*)
incl. non-linearity and hysteresis
5.5 Auxiliary energy
2-Conductor
3-Conductor
Rated Voltage
24v DC
24 V AC/DC
Admissible operating voltage
6 … 30 V DC
19.2 …28.8 V AC/DC
Power input
0.7 W
0.5 W (VA)
5.6 Operating conditions
Ambient temperature range
0 °C … +60 °C
Storage temperature range
-20 °C … +85°C
Medium temperature range
0 °C … +85 °C
EMC
EN 61326-1:2013
EN 61326-2-3:2013
RoHS
EN 50581:2012
Type of protection:
IP 65 acc. to EN 60529
Materials of the parts that come into contact with the surroundings
Casing
CrNi Steel 1.4305
Device plug screw lid
Polypropylene, black
Device plug
Polyamide, brass, zinc
Cable socket
Polyamide, polycarbonate, brass, zinc
Materials of the parts that come into contact with the measuring medium
Process connection
CrNi Steel 1.4404
Sensor membrane
Ceramic Al
2
O
3
Seal
1)
FKM
Fluorinated rubber, Viton®
CR
Chloroprene rubber, Neoprene®
EPDM
Ethylene propylene diene rubber
H-NBR
Hydrogenated acrylonitrile butadiene rubber
(for hot water applications)
1)
see order code
Содержание ME11 Series
Страница 1: ...Operating manual ME11 Pressure Transmitter 09005184 BA_EN_ME11 Rev ST4 B 04 22 09005184...
Страница 21: ...FISCHER Mess und Regeltechnik GMBH Attachments 7 BA_EN_ME11 21 24 7 Attachments Fig 16 CE_EN_ME11...
Страница 22: ...7 Attachments FISCHER Mess und Regeltechnik GMBH 22 24 BA_EN_ME11 Fig 17 UKCA_EN_ME11...
Страница 23: ...FISCHER Mess und Regeltechnik GMBH BA_EN_ME11 23 24 Notes...