5
FISCHER
FIBEROPTIC
SERIES
MAINTENANCE CLEANING (ultrasonic cleaning) - FO1, FO2 &FO4
■
Put your connector under running tap water until everything is globally cleaned
■
Remove the sleeve holder, manually unscrew it for FO1 or use tweezers for FO2, FO4 and FOH and repeat the
cleaning with the IBC
TM
Brand cleaner
■
Put the connector & the sleeve holder in the ultrasonic bath for ~1 minute.
■
Dry the contacts
&
connector by spraying canned air on it.
■
Dry the sleeve holder by spraying canned air on it
■
Reassemble the sleeve holder
■
Slightly grease the plug sealing plan to recover full sealing capabilities*
■
Ultrasonic bath
Recommended bath composition: Isopropyl alcohol
<
5
min
■
Tweezers
*Grease
What you need
■
Canned air
■
Running Tap water
Procedure