5 | Technical Data
FISCHER Mess- und Regeltechnik GmbH
12 / 20
BA_EN_DE23
5 Technical Data
5.1 Generalities
Reference conditions (acc. to IEC 61298-1)
Temperature
+15 … +25 °C
Relative humidity
45 … 75 %
Air pressure
86 … 106 kPa
860 … 1060 mbar
Installation position
User-defined
All information in the technical data refer to one measuring value channel. The
technical data for the second measuring value channel is identical and is there-
fore not listed.
5.2 Input variables
Measured variable
Differential pressure, positive and negative over-pressure
Mearuring ranges
Relative pressure
+/- measuring ranges
asymmetric
0 … 25 Pa
± 25.0 Pa
-20 … +80 Pa
0 … 50 Pa
± 50.0 Pa
0 … 100 Pa
± 100.0 Pa
0 … 250 Pa
± 250.0 Pa
0 … 500 Pa
0 … 1000 Pa
For all measuring ranges:
Max. system pressure
stat. pressure
1 bar
Bursting pressure on
one side
1,7 bar
5.3 Output sizes
Current output
Voltage output
Output signal
4 … 20 mA
0 … 10 V
Apparent ohmic resist-
ance
R
L
≤ (U
b
-12 V)/0.02 A
Characteristic curve
linear
linear
Connection type
2-Wire
3-Wire
5.4 Measurement accuracy
Characteristic curve deviation
1)
1 % FS
2)
Reproducibility
0.1 % FS
TK zero-point and range
3)
0.6 % FS / 10 K
Long-term stability
≤ 0.5 % FS / year
Response time (10 … 90 %)
250 ms
1)
Non-linearity and hysteresis at 25 °C
2)
FS: Full Scale (measurng range span)
3)
Compensation range 4 … 50 °C
Содержание DE23 Series
Страница 1: ...Operating manual DE23 Differential pressure transmitter 09005097 BA_EN_DE23 Rev ST4 B 07 18 09005097...
Страница 18: ...7 Annex FISCHER Mess und Regeltechnik GmbH 18 20 BA_EN_DE23 7 Annex Fig 13 CE_DE_DE23...
Страница 19: ...FISCHER Mess und Regeltechnik GmbH Annex 7 BA_EN_DE23 19 20...
Страница 20: ...7 Annex FISCHER Mess und Regeltechnik GmbH 20 20 BA_EN_DE23...