Installation Instructions
Seite/Page 82 Panda PMS 8.000 NE - 42 NE Manual.R05 - Kapitel/Chapter 5: Installation Instructions
22.3.11
5.7
Installation of the fuel system
5.7.1 General references
Inside the generator capsule itself, there is the fuel filter installed (exception: Panda 4200 and 4500). Additional fuel
filters (with water separator) must be mounted outside the capsule in easily accessible places in the fuel lines bet-
ween the tank intake fuel pump and the diesel motor's fuel pump.
Generally forward and return fuel flow pipes must be mounted to the diesel tanks. Do not connect the generator fuel
supply lines with any other fuel lines of other diesel systems.
• The following items need to be installed:
• Fuel supply pump (DC)
• Pre-filter with water separator (not part of the delivery)
• Fine particle fuel filter
• Return fuel line to fuel tank (unpressurized)
The fuel supply pump should be mounted as close to the fuel tank as possible. The electric cable for the fuel pump
is already installed on the generator (length 5 m).
Fig. 5.7.1-1: Installation Scheme Fuel System
1
2
3
4
5
8
7
6
1. Generator
2. Fuel stopcock
3. Fuel filter
4. Fuel return
5. Condensation water suction pump (optional)
6. Fuel tank
7. Fuel supply
8. Electrical fuel pump (DC)
Содержание 6500 PMS
Страница 58: ...The Panda Generator Seite Page 58 Panda_6500_7mini_PMS_eng R01 Kapitel Chapter 4 The Panda Generator 22 3 11 ...
Страница 168: ...Seite Page 168 Panda PMS 8 000 NE 42 NE Manual R05 22 3 11 Leere Seite Intentionally blank Generator Faults ...
Страница 214: ...Seite Page 214 Panel Generator Control P6 RE0703_Kunde_eng R06 1 22 3 11 Leere Seite Intentionally blank Measurements ...