5.4.7 Indirect Cooling of the Genset Housing (by the Heat Exchanger)
Fig. 5.4.7-1: Installation Scheme Indirect Cooling of teh Genset Housing
5.5
Installation of the cooling system - fresh water
5.5.1 Position of the external cooling water expansion tank
Fig. 5.5.1-1: Position of the External Cooling Water Expansion
Tank
Position of the external cooling water expansion tank
The Panda generator is normally supplied with an additional,
external cooling water expansion tank. This tank must be
installed in such a way that its lower edge is at least 500 mm
more highly arranged than the upper edge of the sound
cover.
If this 500 mm should be fallen below, i.e. the cooling water
expansion tank is lower installed, very large problems can
occur with filling and ventilating. Extend and displace the
hose lines to the outside or possibly even up to the deck.
1. Vent valve
2. Exhaust manifold
3. Raw water pump (Raw water impeller pump)
4. Heat exchanger
5. Raw water filter
6. Water cock
7. Hull inlet