The Panda Generator
22.3.11
Panda_6500_7mini_PMS_eng.R01 - Kapitel/Chapter 4: The Panda Generator Seite/Page 55
Fig. 4.3.7-1: Thermo-switch at cylinder head
Thermo-switch at cylinder head
The thermo-switch at the cylinder head serves to monitor the
generator temperature.
83 / 78 ° C
Fig. 4.3.7-2: Thermo-switch at exhaust elbow
Thermo-switch at water-cooled exhaust elbow
This thermo-switch is located at the water-cooled exhaust
elbow and serves to monitor the freshwater circulation
system. It takes a measurement at the warmest spot, since
the combustion gases are guided from the cylinder head to
the exhaust elbow.
83 / 78 ° C
Thermo-switch in the stator winding
Thermo-switch 2 x 165 / 175 ° C
Two thermos-switches and one NTC inside the winding protect the stator winding, which for safety reasons are
installed independently in parallel.
Fig. 4.3.7-3: Oil pressure switch
Oil pressure switch
In order to be able to monitor the lubricating oil system, an oil
pressure switch is built into the system.
4.3.8 Components of Oil Circuit