Maintenance Instructions
26.1.11
Panda_4000s_PMS_SCB_FCB_eng.R04 - Kapitel/Chapter 6: Maintenance Instructions Seite/Page 99
Warning!:
Batteries contains acid or alkalis.
Improper handling can result in battery explosion and lea-
kage. Acid or alkalis can run out. An explosion of the battery
is possible.
See the operation and safety instruction from your battery
manufacturer.
6.3
Environmental protection
Environmental protection.
Danger to the environment due to mishandling!
Significant environmental damage can occur, particularly for
incorrect disposal, if environmentally hazardous operating
materials are mishandled. Therefore:
– Always observe the instructions mentioned below.
– Take immediate action if environmentally hazardous mate-
rials reach the environment. Inform the responsible local
authorities about the damage in the case of doubt.
The disposal must be performed by a specialist disposal
company.
6.4
General maintenance instructions
6.4.1 Checks before starting
• Oil level
• Cooling system leaks
• Visual check for any changes, leaks oil drain system, v-belt,
cable connections, hose clips, air filter, fuel lines
6.4.2 Hose elements and rubber formed component in the sound cover
Check all hoses and hose connections for good condition. The rubber hoses are very sensitive to enviromental influ-
ences. They can season fast with dry air, in which environment of muted oil and fuel steams and increased tempera-
ture. The hoses must be checked regularly for elasticity. There are operating situations, at which the hoses must be
renewed once in the year.
Additionally to usual tasks of maintenance (oil level check, oil filter control etc.) further maintenance activities are to
be accomplished for marine gensets. It belongs control of the sacrificial anode (cooling water connection block) and
the front seal cover at the generator.
For maintenance intervalls see „General information for PMS-Generators“
6.5
Oil circuit maintenance
The first oil change is to be accomplished after a period of operation from 35 to 50 hours. Afterwards
the oil is to be changed after 150 hours. For this the oil SAE30 for temperatures over 20°C
Содержание 4000s PMS FC
Страница 24: ...Seite Page 22 General R01 1 26 1 11 Leere Seite Intentionally blank General References and Regulations...
Страница 68: ...Seite Page 66 Panda_4000s_PMS_SCB_FCB_eng R04 26 1 11 Leere Seite Intentionally blank The Panda Generator...
Страница 112: ...Seite Page 110 Panda_4000s_PMS_SCB_FCB_eng R04 26 1 11 Leere Seite Intentionally blank Maintenance Instructions...
Страница 122: ...Seite Page 120 Panda_4000s_PMS_SCB_FCB_eng R04 26 1 11 Leere Seite Intentionally blank Generator Failure...