1.5.7 Safety precautions against burns and battery explosions
The generator and its cooling agents and lubricants as well as the fuel can get hot while the
generator is operated. Use caution around hot components such as parts containing exhaust
fumes, radiator, hoses, and engine block during operation and after the generator was shut
down.
The cooling system may be pressurised. Open the cooling system only after letting the engine
and the coolant cool down. Wear appropriate protective clothing (e.g. safety goggles, gloves).
Prior to operation, ensure that the cooling system is sealed and that all hose clamps are
tightened.
The battery represents an explosion hazard, this applies both to the starter battery and the
batterybank of the AGT generators. While batteries are being charged, a hydrogen-oxygen
mixture is generated, which is highly explosive (electrolytic gas).
Do not use or charge batteries if the fluid level is below the MINIMUM marking. The lifespan of
the battery is significantly reduced, and the risk of explosion increases. Refill to a fluid level
between maximum and minimum level without delay.
Especially during charging, keep sparks and naked fire away from the batteries. Ensure that the
battery terminals are tightly connected and not corroded to avoid sparking. Use an appropriate
terminal grease.
Check the charge level with an adequate voltmeter or acid siphon. Contact of a metal object
across the terminals will result in short-circuiting, battery damage, and high explosion risk.
Do not charge frozen batteries. Heat the batteries to +16 °C (61 °F) prior to charging.
1.5.8 Protect your hands and body from rotating parts!
Always keep the capsule closed while operating the generator.
To check the V-belt tension, always shut down the generator.
Keep your hands and body away from rotating parts such as V-belt, fans, pulleys, and flywheel.
Contact can cause severe injury.
Do not run the engine without the safety devices in place. Prior to start-up, mount all safety
devices securely and check for proper attachment and function.
1.5.9 Anti-freeze and disposal of fluids
Anti-freeze contains toxic substances. To prevent injury, wear rubber gloves and wash off any
anti-freeze immediately in case of skin contact. Do not mix different anti-freeze agents. The
mixture may cause a chemical reaction generating harmful substances. Use only anti-freeze that
was approved by Fischer Panda.
Protect the environment. Collect drained fluids (lubricants, anti-freeze, fuel), and dispose of them
properly. Observe the local regulations for the respective country. Ensure that no fluids (not even
very small quantities) can drain into the soil, sewers, or bodies of water.
Содержание 22-4 HD PVMV-N
Страница 8: ...Seite Page 8 Kapitel Chapter 2 10 5 11 12 Measurements 153 12 1 Hole pattern 153 ...
Страница 25: ...General Instructions and Regulations 10 5 11 Chapter 1 General Instructions and Regulations Page 25 ...
Страница 52: ...Seite Page 52 10 5 11 Leere Seite Intentionally blank The Panda Generator ...
Страница 94: ...Seite Page 94 Panda 8000 42NE PVMV N R01 10 5 11 Leere Seite Intentionally blank Maintenance Instructions ...
Страница 154: ...Seite Page 154 Panel Generator Control P6 RE0703_Kunde_eng R06 1 10 5 11 Leere Seite Intentionally blank Measurements ...