Maintenance Instructions
Seite/Page 144 - Kaptitel/Chapter 9: Maintenance Instructions
9.12.14
9.14.4 Ventilation of the coolant circuit / freshwater
Attention
Special notes for the ventilation of the cooling system
If the cooling water is drained, or if other air has entered the
cooling system, it is necessary to ventilate the cooling
system.
This ventilating procedure must be repeated several times:
The generator must be switched off before opening the
ventilating points!
Pay attention that the external coolant expansion tank is
connected with the generator by the intended
connection point.
Further it should be guaranteed that the expansion tank
is attached in sufficient height (600 m) over the level of
the generator exhaust elbow union.
Fig. 9.14-1: Expansion tank
Expansion tank
Fig. 9.14-2: Ventilating screw
1. Open the ventilating screw above the cooling water pump
casing. Not present at all models
Use spanner size 10 mm.
Not present at all models
Содержание 10000/9
Страница 10: ...Seite Page 10 Kapitel Chapter 2 9 12 14 Leere Seite Intentionally blank...
Страница 62: ...The Panda Generator Seite Page 62 Kaptitel Chapter 6 The Panda Generator 9 12 14...
Страница 220: ...Tables Seite Page 220 Kaptitel Chapter 11 Tables 9 12 14...
Страница 244: ...Seite Page 244 Kapitel Chapter 13 General operation 9 12 14 Leere Seite Intentionally blank General operation...
Страница 246: ...Seite Page 246 Kapitel Chapter 14 Measurements 9 12 14 Leere Seite Intentionally blank Measurements...