First Alert ONELINK CM2837 Скачать руководство пользователя страница 1

 

 

                   Page 1 of 9                                                                 

CM2837 

**Interconnected alarms provide added 
warning as compared to single alarms. 

Bridge Unit  

120V AC Hardwired 

Smoke Alarm 

SA520B 

Battery Smoke/CO 

Combination Alarm 

with Voice 

SCO500B 

Battery 

Smoke Alarm  

with Voice 

SA511B 

Battery Carbon 

Monoxide Alarm 

with Voice 

CO511B 

WIRELESS 

I

I

n

n

t

t

r

r

o

o

d

d

u

u

c

c

t

t

i

i

o

o

n

n

 

 

First Alert

®

 OneLink

®

 is a line of wirelessly interconnectable alarms designed to meet the 

needs of contractors that retrofit or remodel existing properties. First Alert® 

OneLink® offers the same interconnected functionality as hardwired alarms, 
without the wires. Because there are no wires to pull through existing walls, 

First Alert® OneLink® offers a very cost effective way to bring existing 
properties up to code. Using First Alert® OneLink® provides faster job 
turnaround vs. hardwire retrofitting applications. Up to 4X more jobs completed 
means increased profits and customer satisfaction. 
 

The product line consists of mostly battery operated alarms making installation fast and easy. 
A hardwired bridge unit is used to connect existing hardwired alarms to the new First Alert® 
OneLink® enabled alarms providing a complete system, old and new. With exclusive features 
like Voice Warning with Location™, Optipath 360 Technology™ and Spread Spectrum Horn 
Tone, First Alert has the most complete lineup of wireless smoke and CO products: 

 
 
 
 

Содержание ONELINK CM2837

Страница 1: ...out the wires Because there are no wires to pull through existing walls First Alert OneLink offers a very cost effective way to bring existing properties up to code Using First Alert OneLink provides faster job turnaround vs hardwire retrofitting applications Up to 4X more jobs completed means increased profits and customer satisfaction The product line consists of mostly battery operated alarms m...

Страница 2: ...s When seconds count in an emergency it provides an audible indication of the possible threatened area and more importantly what area to investigate or avoid Question How do the First Alert OneLink alarms communicate with each other Answer The alarms interconnect via reliable and secure radio frequency RF communication They operate on the 915MHz frequency bandwidth and employ 3 channel frequency h...

Страница 3: ...resend the initiating alarm s signal The competition only sends and receives or is a one way communication It does not resend Why is this important In the following illustration the initiating alarm is in the basement Let s say the signal is blocked from reaching the Master Bedroom alarm either by distance or some obstruction in the home With First Alert OneLink the mesh network of alarms re route...

Страница 4: ...programmed for the location of your choice ADDING AND LINKING ADDITIONAL ONELINK ALARMS NOTE Steps 1 through 3 below need to be completed within two minutes If more than two minutes pass the Green power LED will stop blinking Simply open the battery drawer of the second Alarm and repeat steps 1 through 3 1 Insert the batteries into the battery drawer of the next Alarm DO NOT CLOSE THE DRAWER 2 Pre...

Страница 5: ...by builders as evidenced by the increase in the development of more Over 55 communities American s 55 and older will head 40 of the nation s households by 2012 No other alarm manufacturer has recognized this potential and has this feature to date Question How can First Alert OneLink alarms be relevant for contractors who have existing home additions projects Answer When dealing with new constructi...

Страница 6: ...nect to an existing alarm circuit and incur drywall repairs painting etc This does not account for special cases requiring conduit in some parts of the country wire mold concrete drilling etc Turnaround time is much faster Case in point Penn State University in State College PA accepted First Alert OneLink alarms as a viable alternative to hardwiring alarms in existing off campus housing Code offi...

Страница 7: ...ds to have the battery replaced Although the alarm will sound the low battery chirp approximately once every minute sometimes during the initial stages of low battery the alarm will chirp in greater intervals than once per minute sometimes up to several hours until the battery reaches a steady low battery level This innovative feature eliminates the frustration of waiting for and or identifying wh...

Страница 8: ...s from cooking smoke and steam from showers Nuisance issues with tenants is time consuming and costly Some areas of the country require photoelectric alarms near high nuisance areas like kitchens and bathrooms Requires only 2 AA batteries vs 3 AA batteries with the competition This saves 33 in annual battery replacement costs For large apartment complexes this can add up to thousands in savings pe...

Страница 9: ...0 year limited warranty and CO s or Smoke CO combos have a 5 year limited warranty First Alert OneLink Competitive Comparison Summary Feature Competitive Wireless SKU Lineup Smoke and CO alarms 4 SKUS Smoke alarms only 2 SKUS Smoke Sensing Technology Photoelectric Ionization Patented Optipath 360 Smoke Technology Yes No Electrochemical CO Sensor Yes No CO Alarm Pullout Battery Drawer Yes No Voice ...

Отзывы: