N7227–1V1 Rev B  4/99

Содержание FA142C

Страница 1: ...INSTALLATION INSTRUCTIONS F F F FA A A A1 1 1 14 4 4 42 2 2 2C C C C S S S SE E E EC C C CU U U UR R R RI I I IT T T TY Y Y Y S S S SY Y Y YS S S ST T T TE E E EM M M M N7227 1V1 Rev B 4 99...

Страница 2: ...alarm in the hallway outside may not wake up the sleeper if the door is closed Install a smoke detector inside bedrooms where electrical appliances such as portable heaters air conditioners or humidif...

Страница 3: ...es 1 6 19 Wiring 4 Wire Smoke Combustion Detectors on Zones 5 19 Compatible 4 Wire Smoke Combustion Detectors 20 Turning Off Fire Alarm Sounding 20 Programming Hard Wired Zones 20 Check Out Procedure...

Страница 4: ...44 Supervision 44 Programming Options Defined 45 Programming Output Relays 47 Example of Output Relay Programming 48 Section 8 FA4285 PHONE MODULE 50 Installing the FA4285 Phone Module 50 General Info...

Страница 5: ...Code 79 Assigning the Master Code 79 Changing the Master Code 79 User Codes 79 Duress Code 79 Keypad Functions 80 General Information 80 Arming Disarming Functions etc 80 Panic Keys 81 FA4285 Phone M...

Страница 6: ...4 Wire Smoke Detector Connections to Zone 5 19 Figure 8 Wiring Connections 4219 4229 4229 shown 23 Figure 9 5881 and 5882 Wireless Receivers cover removed 29 Figure 10 4204 Connections To Control 44 F...

Страница 7: ...ime e g adding Wireless zones adding an FA4285 Phone Module etc Without an understanding of the programming method for this system you will not be able to successfully perform the required programming...

Страница 8: ...difficulties This symbol indicates the presence of critical information that if not observed could seriously affect the operation of the system or could cause damage to the system Please read each war...

Страница 9: ...RF Receiver with 5800 series wireless transmitters as shown below Receiver Model No of Zones Transmitter Type 4281L Up to 4 5700 4281M Up to 8 5700 4281H Up to 30 5700 5881L 5882L Up to 8 5800 5881M U...

Страница 10: ...for protection Auxiliary Power Output Provides 12VDC 500mA max Uses current limiting circuitry for protection This output interrupts for smoke detector reset if 4 wire smoke detectors are used on bas...

Страница 11: ...and or block RF transmissions from wireless transmitters Do not locate the cabinet in an area of high RF interference revealed by frequent or prolonged lighting of the LED in the receiver after it is...

Страница 12: ...s DIP switch is set with its position 1 ON to the right as shown in its instructions The 4219 s or 4229 s cover can be left off if the cover tamper jumper is placed in its up per not tampered positio...

Страница 13: ...cabinet into the left hand terminals of the antenna blocks at the upper edge of the receiver board and secure them to the cabinet top with the screws provided as shown in Detail D 7 Insert the receiv...

Страница 14: ...NG RJ31X JACK PLUG DIRECT CONNECT CORD TIP RING GROUND INCOMING TELCO LINE 17 18 19 20 21 CA38A JACK IN CANADA Figure 4 Standard Telephone Line Connections Wiring The AC Transformer 1321 Transformer 1...

Страница 15: ...arth Ground Connections The designated earth ground terminal 21 must be terminated in a good earth ground for the lightning transient protective devices in this product to be effective The following a...

Страница 16: ...e Current Draw Worksheet in the FINAL POWER UP section for current draw for all keypads Maximum wire lengths for any device that is homerun to the control can also be determined from the chart based o...

Страница 17: ...ower supply e g 487 12 supplies 12V 250mA 488 12 supplies 12V 500mA Use a UL Listed battery backed supply for UL installations The 487 12 488 12 power supplies have a backup battery which can power th...

Страница 18: ...yed After approximately 1 minute the green READY LED should light and the word READY Fixed word keypads or DISARMED READY TO ARM Alpha keypads should be displayed To bypass the 1 minute delay press pl...

Страница 19: ...ircuit devices in parallel across the loop The 1 000 ohm EOLR must be connected across the loop wires at the last device If the EOLR is not at the end of the loop the zone will not be properly supervi...

Страница 20: ...e next prompt will ask you to enter zone number Enter Zn Num 00 Quit 01 Default Zone Number after after entering 56 Enter the first zone number that you wish to program or 0 0 to exit zone programming...

Страница 21: ...zone that was just programmed If it is programmed satisfactorily press to continue Program Alpha 0 No 1 Yes 0 The next request is to enter Alpha descriptors for the zones The entry may be done now en...

Страница 22: ...retain all data except the original zone type You can then go back to this zone later and put back an active Zone Type to re enable it Check Out Procedure For Basic Hard Wired Zones 1 6 After installa...

Страница 23: ...section Connections and Set Up 1 2 3 4 5 OFF ON ON e e h h h h h h e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e g g g g g g 1 Connect the 4219 or 4229 module to the control s keypad ter...

Страница 24: ...ult Press to continue Zn ZT RC In L 10 00 00 RF 1 A summary display will appear showing the present status of that zone s programming Zn zone number ZT zone type RC report code for that zone In input...

Страница 25: ...ed with the programming for the next zone as indicated previously When all wired expansion zones are programmed satisfactorily exit 56 mode at the Enter Zn Num prompt by pressing 0 0 Exit the programm...

Страница 26: ...s programmed by you just previously in 56 mode When each zone is restored the READY TO ARM message should appear again 4 When you get the proper displays on the keypad s the wired expansion zones in t...

Страница 27: ...d In Canada 5700 systems must use 4281CN series receivers 4281CN L 4281CN M or 4281CN H with Canadian versions of 5700 type transmitters 5800 systems must use 5882 series receivers 5882L or 5882H Info...

Страница 28: ...Button type transmitters e g 5802 5802CP 5804 should be periodically tested by the user for battery life Receiver Supervision The receiver itself is supervised A tamper report zone 9 will be generate...

Страница 29: ...t the 5800TM to the control panel s keypad connection terminals using the supplied connector with flying leads as follows WIRE TERMINAL ON CONTROL RED 12VDC Terminal 5 BLACK Ground Terminal 4 GREEN Da...

Страница 30: ...tain range of zone numbers Each range of zone ID numbers is shown below Zone Type Transmitter Zone ID Entry Exit Burg 10 through 47 Perimeter Burg 10 through 47 Interior Burg 10 through 47 32 through...

Страница 31: ...P UP UP 45 UP UP 46 UP UP 47 UP 48 UP UP UP UP 49 U UP UP 50 UP UP UP 51 UP UP 52 UP UP UP 53 UP UP 54 UP UP 55 UP 56 UP UP UP 57 UP UP 58 UP UP 59 UP 60 UP UP 61 UP 62 UP 63 BIT VALUE 32 16 8 4 2 1 5...

Страница 32: ...63 Detects the sound and shock of Glassbreak Detector breaking glass and requires the presence of both to initiate an alarm condition 5775 PIR Detector 32 47 Dual element passive infrared detector wi...

Страница 33: ...1 series RF receivers respond only to 5700 transmitters and 5827BD wireless keypads set to the same House ID 01 31 programmed into the control panel This prevents system interference from transmitters...

Страница 34: ...step and enter another zone number if desired If the zone is not programmed or you want to change it press A prompt for Zone Type will appear Zone Number 20 Zone Type Perimeter 03 Entry for Zone Type...

Страница 35: ...e number will advance to the next programmed zone When the end of the list is reached press 0 0 to exit This method of exiting may also be done at any time during the review To either temporarily or p...

Страница 36: ...for UL Household Burglary installations the loop wiring may not exceed 3 ft Programming an RF House ID 01 31 in field 24 is necessary only if using 5827 or 5827BD wireless keypads An RF House ID is no...

Страница 37: ...th a Transmitter unique input loop code Programmable responses e g Arm Stay Arm Away Disarm etc 5806 Wireless Photoelectric RF One piece smoke detectors with a 5807 Smoke Detectors built in transmitte...

Страница 38: ...sed with 5800TM Can indicate system status via its 3 LEDs and sounder Includes 3 panic keys House ID must be set Requires 5800TM Transmitter Module 5850 Glass Break Detector RF Requires both sound and...

Страница 39: ...am it as the tool Batteries can remain in the transmitters after the transmitters have been enrolled into the system However to prevent possible problems make sure these transmitters are not faulted w...

Страница 40: ...Trans RF 1 8 Enter the transmitter input device type as follows 3 RF supervised RF transmitter 4 UR unsupervised RF transmitter 5 BR button type RF transmitter unsupervised Refer to the separate Progr...

Страница 41: ...program tool a single short beep will verify the system is ready for enrolling and re activate the proper transmitter or transmitter loop input ZN ZT RC IN L 10 03 00 RF 1 s 13 The summary screen for...

Страница 42: ...he 56 Mode 1 In the programming mode press 5 6 to enter Zone Programming mode 2 Then enter the zone number and press repeatedly until the cursor is under the RF Input Loop L position This is the speci...

Страница 43: ...Code 4 2 Once transmitters are placed in their desired locations and the approximate length of wire to be run to sensors is connected to the transmitter s screw terminals fault each transmitter Do no...

Страница 44: ...p 1 2 3 4 5 OFF ON ON e e h h h h h h e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e g g g g g g The 4204 unit can be mounted either remotely or in the control panel The following steps s...

Страница 45: ...rogrammed data during programming ACTION A The ACTION of the relay is how the relay will respond when it is activated by the START programming You may want the relay to activate momentarily to pulse o...

Страница 46: ...y will de activate when all the zones in that list restore from a previous fault trouble or alarm condition This will occur regardless of what is programmed to START the relay therefore a RESTORE ZONE...

Страница 47: ...to the next prompt The key is used to revert back to the last question to check or change an entry Press to go forward again 02 A EV ZL ZT STT 0 0 0 00 This screen displays a summary of the current R...

Страница 48: ...can be entered or enter 0 0 to end relay programming Previously entered data can be reviewed by pressing 8 0 After the relay number is chosen press to go to the next screens This is a review mode onl...

Страница 49: ...urn to the first screen To save the zone list enter 0 No to advance 01 Delete Zone 0 No 1 Yes 0 To delete a zone or zones in a zone list enter 1 Yes to advance 01 Zn to Delete 00 Quit 00 Enter each zo...

Страница 50: ...for Touch tone temporarily before attempting phone access A Phone Access User s Guide is provided with the Phone Module for the user of the system UL The Phone Module is not Listed for UL installation...

Страница 51: ...e additional wires to them as required FA4285 WIRING TABLE FA4285 Terminal Connects to 1 Phone In Tip Terminal 17 on control 2 Phone In Ring Terminal 18 on control 3 Phone Out Tip BROWN lead from dire...

Страница 52: ...CO LINE NOT INSTALLER ADJUSTABLE UNUSED KEYED HEADER 4285 VOICE MODULE 1 2 3 4 5 6 7 YELLOW TO DATA OUT term 7 NO CONNECTION RED TO AUX term 5 BLACK TO AUX GROUND term 4 GREEN TO DATA IN term 6 CONNEC...

Страница 53: ...f rings for which the answering machine is set Example if the machine is set for 4 rings use a value of 5 or higher This is recommended so that the Phone Module can still be accessed if the answering...

Страница 54: ...phone code should be entered during a pause at the beginning of or during the outgoing answering machine message Note If 15 was entered in field 95 to bypass an answering machine and an FA4285 Phone M...

Страница 55: ...watt speaker 1 3 amps current draw Ademco 745X3 Voice Siren Driver 12 volt voice siren driver with English Spanish and French voice messages Separate messages for Fire and Burglary Use with 8 ohm spe...

Страница 56: ...m 2 Enter the programming mode by keying the following on the Alpha keypad INSTALLER code 4 1 1 1 8 0 3 Press 28 Single Alarm Sounding per Zone Armed Period Enter 1 for yes 0 for no default 4 Press 29...

Страница 57: ...RADIO BLACK RED GREEN YELLOW 4 5 6 7 CONTROL TERMINALS Figure 14 Long Range Radio Connections Programming for Long Range Radio 1 With at least one keypad connected to the keypad terminals on the cont...

Страница 58: ...hold the phone connection for 1 minute Once the digital message is kissed off the control will give up the phone line to the AAV module without breaking connection with the central station At this tim...

Страница 59: ...R ANY OTHER PURPOSE 21 Figure 15 Connection Of AAV Unit When Not Using An FA4285 Voice Module 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ON MODEL EAGLE SECURITY 1241 GND VDC RING TIP REFER TO AAV MODULE I...

Страница 60: ...ttery The minimum battery size recommended is the No 467 12V 4AH battery See Calculating the Battery Size Needed below The battery is installed in the control cabinet The standby battery connection is...

Страница 61: ...EET CURRENT NUMBER OF TOTAL CURRENT DEVICE USED DRAW DEVICES device mA x of units FA210KP Keypad 30mA FA250KP Keypad 120mA FA550KP Keypad 140mA 4281 5881 5882 Type RF Receiver 35mA 4204 Relay Module 1...

Страница 62: ...o the system Each descriptor can be composed of a combination of words up to a maximum of 3 selected from a vocabulary of words stored in memory the list is on a following page In addition up to 5 ins...

Страница 63: ...A summary display for that zone will appear You must then press plus the same zone number again to gain access to the entry mode flashing cursor for that zone Flashing Cursor ZN 01 B ACK ZN 01 BACK Fl...

Страница 64: ...display Program Alpha 0 No 1 Yes 00 The Program Alpha prompt will be displayed 13 Press 0 Alpha Pgm 82 This will be displayed 14 Press 99 to exit the programming mode Adding Custom Words will not be a...

Страница 65: ...the desired word s Note that the 4 key can be used to move the cursor to the left if necessary Remember no word or word string can exceed 10 characters 6 Press the 8 key to save the custom word s and...

Страница 66: ...ERY O 136 OFFICE 138 OPEN 139 OPENING 140 OUTSIDE 142 OVERHEAD P 143 PAINTING 144 PANIC 145 PASSIVE 146 PATIO 147 PERIMETER 148 PHONE 150 POINT 151 POLICE 152 POOL 153 POWER R 155 RADIO 156 REAR R 155...

Страница 67: ...ypad Enter the Serial Number Sequential mode by pressing 83 The following prompt will be displayed Program Tool 0 No 1 Yes 0 2 If using a program tool enter 1 If not using a tool enter 0 If a tool has...

Страница 68: ...tem a single long beep will be heard from the keypad If this happens the system will not display the serial number but will wait for a transmission from another transmitter or transmitter loop input 6...

Страница 69: ...After all wireless zones have been displayed whether enrolled or not the Enter Zn Num prompt will appear Enter 00 to exit the Sequential mode and return to data field programming mode When you have fi...

Страница 70: ...t attempts to the secondary telephone number if programmed to get a valid message through If the panel is not successful after its numerous attempts the keypad will display Communication Failure Alpha...

Страница 71: ...in hex Z Typically Zone Number 2nd digit Gg Test Code 1st 2nd digits Tt Trouble Code 1st 2nd digits R Restore Code Alarm Bb Bypass Code 1st 2nd digits R Tt Restore Code Trbl 1st 2nd digits EAC AC Los...

Страница 72: ...t to power up the system 2 Enter the programming mode by keying the following on the Alpha keypad Installer code 4 1 1 1 8 0 Fields 40 41 42 Enter up to the number of digits shown Do not fill unused s...

Страница 73: ...er Reports 2 All except Open Close Test Open Close Test 3 Alarms Restore Cancel All reports 4 All except Open Close Test All reports 5 All reports All reports TO PRIMARY PHONE TO PAGING NUMBER 6 All r...

Страница 74: ...0 for all other formats Default is 0 TO PROGRAM SYSTEM STATUS AND RESTORE REPORT CODES 60 68 70 75 With a 3 1 or 4 1 Standard Format Enter a code in the first digit box 1 9 0 B C D E or F Enter 10 for...

Страница 75: ...condition exists Press 68 CANCEL REPORT CODE This is sent upon disarming of the system after an alarm condition was reported Press 70 ALARM RESTORE REPORT CODE 1st DIGIT This is sent when the zone th...

Страница 76: ...all Yes No Yes Set for value other than 0 1 14 Yes Yes Yes 15 to bypass answering machine No No No Enter 0 No Yes No Enter 0 No No Yes Enter 1 14 No Yes Yes Enter 15 See Imortant Note below Important...

Страница 77: ...utes 5 Follow the manufacturer s instructions to test all smoke detectors to ensure that all are functioning properly The identification of each detector should appear on the display when each is acti...

Страница 78: ...cations for the transmitters when the system is being installed but also verifies that the RF transmission has sufficient signal amplitude margin for the installed system 1 Enter the Installer Code 4...

Страница 79: ...n be assigned to User No 8 if a Duress code has not been assigned The system will emit a single beep when each secondary code has been suc cessfully entered To delete a Secondary security code enter v...

Страница 80: ...pending on keypad type see Panic Keys on next page for silent audible fire or personal emergency alarms These keys can notify the central station of an alarm condition if that service is connected Arm...

Страница 81: ...he Phone Module cannot be used to add user codes in this system User codes must be added by using a wired keypad Relay Outputs if used If relay outputs are used two keypad entries available to the use...

Страница 82: ...ition exists in the wireless sensor displayed zone 00 indicates a wireless keypad If the battery is not replaced within 30 days a CHECK display may occur Note Some wireless sensors contain a non repla...

Страница 83: ...pad 3a Bat or System Lo Bat no zone Nos 3b Bat or Lo Bat 00 3c Bat or Lo Bat nn 3a System battery is low or missing 3b Remote RF keypad battery is low 3c Transmitter for zone nn has a low battery 4 Pe...

Страница 84: ...light off or NO AC displayed 1a Interrupted AC power supply 1a Check transformer connection and power line circuit breaker 2 Digital communicator mes sage not being received 2a Control in TEST mode 2...

Страница 85: ...ly and effectively You may contact Technical Support via Toll Free FAX Please include your return FAX number You will receive a reply within 24 hours You may also contact Technical Support via modem t...

Страница 86: ...a Tones 1400 2300Hz ACK 1400Hz KISSOFF Ademco Contact ID Reporting 10 characters sec DTMF Touch Tone Data Tones 1400 2300Hz ACK 1400Hz KISSOFF Ademco Low Speed 10 pulses sec 1900Hz Data Tone 1400Hz AC...

Страница 87: ...32mm 2 Electrical Voltage Input 12VDC Current Drain 15mA Relays off 180mA Relays on 3 Interface Wiring Same as FA210KP 4 Four Output Relays SPDT Contacts Rating 2A max at 28VDC AC 4219 WIRED EXPANSION...

Страница 88: ...744 Siren Driver 6 jumper selected sound outputs Rated at 119dB with use of an 8 ohm 30 watt speaker 1 3 amps current draw Ademco 745X3 Voice Siren Driver 12 volt voice siren driver with English Span...

Страница 89: ...the FCC rules On the front cover of this equipment is a label that contains among other information the FCC registration number and ringer equivalence number REN for this equipment If requested this i...

Страница 90: ...capacity to operate the panel and its attached peripheral devices for 24 hours in the intended standby condition followed by at least 4 minutes in the intended fire alarm signaling condition This cont...

Страница 91: ...e tiquette certifie que le mat riel est conforme certaines normes de protection d exploitation et de s curit des r seaux de t l communications Le minist re n assure toutefois pas que le mat riel fonct...

Страница 92: ...ors closed doors glass partitions glass doors or windows Mechanical tampering masking painting or spraying of any material on the mirrors windows or any part of the optical system can reduce their det...

Страница 93: ...HIS EQUIPMENT CHARGING VOLTAGE 13 8VDC BATTERY 12V 4AH e g ADEMCO No 467 OR 12V 1 2AH CONNECTOR TABS FOR COMPLETE INFORMATION SEE INSTRUCTIONS PLUG IN TRANSFORMER 16 5VAC 25VA e g ADEMCO No 1321 USE N...

Страница 94: ...E SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE L...