background image

 

42 

© 2020 Carrier 

10.5

 

BACnet: Setting Node_Offset to Assign Specific Device Instances 

  Follow the steps outlined in 

Section

 10.1 

to access the MB485ETH-CG Web Configurator. 

  The Node_Offset field shows the current value (default = 50,000). 

o

  The values allowed for a BACnet Device Instance can range from 1 to 4,194,303 

  To assign a specific Device Instance (or range); change the Node_Offset value as needed using 

the calculation below: 

Device Instance (desired) = Node_ Node_ID 

For example, if the desired Device Instance for the device 1 is 50,001 and the following is true: 

-  Device 1 has a Node-ID of 1 
-  Device 2 has a Node-ID of 22 
-  Device 3 has a Node-ID of 33 

Then plug the device 1’s information into the formula to find the desired Node_Offset: 

50,001 = Node_ 1

 

 

50,000 = Node_Offset 

Once the Node_Offset value is input, it will be applied as shown below:

 

-  Device 1 Instance = 50,000 + Node_ID = 50,000 + 1 = 50,001 
-  Device 2 Instance = 50,000 + Node_ID = 50,000 + 22 = 50,022 
-  Device 3 Instance = 50,000 + Node_ID = 50,000 + 33 = 50,033 

  Click “Submit” once the desired value is entered. 

 

 

 

 

Figure 45: Web Configurator Node Offset Field 

Figure 46: Active Profiles 

Содержание MB485ETH-CG

Страница 1: ...building management system or PLC using the BACnet IP BACnet MS TP EtherNet IP or Modbus TCP IP protocols Multiple devices can be connected to a single communication gateway Configuration is done usin...

Страница 2: ...note that the manufacturer MSA Safety dba Sierra Monitor does not provide direct support for this Fireye branded product Support Contact Information Fireye Inc 3 Manchester Road Derry NH 03038 Custome...

Страница 3: ...H CG 3 pin power port Section 5 5 6 Connect a PC to the MB485ETH CG via Ethernet cable or by the MB485ETH CG s Wi Fi Access Point Section 6 7 Setup Web Server Security and login via web browser Sectio...

Страница 4: ...17 6 1 1 1 Changing the Subnet of the Connected PC 17 6 1 1 2 Connecting to the MB485ETH CG Over Wi Fi Access Point 18 7 Setup Web Server Security 19 7 1 Login to the MB485ETH CG 19 7 2 Select the Sec...

Страница 5: ...Appendix B 6 1 User Management 58 Appendix B 6 1 1 Create Users 59 Appendix B 6 2 Edit Users 60 Appendix B 6 2 1 Delete Users 61 Appendix B 6 3 Change MB485ETH CG Password 62 Appendix B 7 SMC Cloud Co...

Страница 6: ...Wi Fi AP Network Settings 27 Figure 26 Generic Web App Page First Login 28 Figure 27 SMC Cloud Opt Out Warning Window 29 Figure 28 Welcome to SMC Cloud Email 30 Figure 29 Setting User Details 31 Figur...

Страница 7: ...ate Loaded 57 Figure 58 FS GUI User Management 58 Figure 59 Create User Window 59 Figure 60 Setup Users 60 Figure 61 Edit User Window 60 Figure 62 Setup Users 61 Figure 63 User Delete Warning 61 Figur...

Страница 8: ...s that a product has passed a series of rigorous tests conducted by an independent laboratory which verifies that the product correctly implements the BACnet features claimed in the listing The mark i...

Страница 9: ...tested profiles configurations for the supported devices Connectivity Diagram The MB485ETH CG can connect with the SMC Cloud The SMC Cloud allows technicians the OEM s support team and MSA Safety s s...

Страница 10: ...00 Modbus RTU ZB110_FSG Modbus RTU PPC6000_NX6100 Modbus RTU E110 Modbus RTU MicroM Modbus RTU BurnerPRO_Gen_3 Modbus RTU NXCESO2 Modbus RTU FX_Series_Servos Modbus RTU ACS550 Modbus RTU Insight_Insig...

Страница 11: ...PA W44 units have the following 4 ports Ethernet Wi Fi RS 485 RS 485 RS 232 4 2 Point Count Capacity The total number of points presented to the device s attached to the MB485ETH CG cannot exceed Part...

Страница 12: ...The Node ID assigned is used for deriving the Device Instance for BACnet IP and BACnet MS TP Section 10 5 NOTE The Modbus TCP IP field protocol Node IDs are automatically set to be the same value as...

Страница 13: ...485 Serial Network Connect the RS 485 network wires to the 3 pin RS 485 connector on the R2 port Figure 7 o Use standard grounding principles for RS 485 GND See Section 6 for information on connecting...

Страница 14: ...is in line with the BACnet spec It should only be enabled at one point on the bus for example on the field port were there are very weak bias resistors of 100k Since there are no jumpers many gateways...

Страница 15: ...stor is also used to reduce noise It pulls the two lines of an idle bus together However the resistor would override the effect of any bias resistors if connected NOTE The R1 and R2 DIP Switches apply...

Страница 16: ...commended Figure 10 Required Current Draw for the MB485ETH CG Apply power to the MB485ETH CG as shown below in Figure 11 Ensure that the power supply used complies with the specifications provided in...

Страница 17: ...ferent IP networks assign a static IP Address to the PC on the 192 168 1 xxx network For Windows 10 Find the search field in the local computer s taskbar usually to the right of the windows icon and t...

Страница 18: ...TH CG with Wi Fi To connect to the MB485ETH CG Wi Fi Access Point Click the icon found in the bottom right corner of the computer screen to open the available Wireless Network Connections Select the d...

Страница 19: ...lbox utility See Appendix A 1 for instructions 7 1 Login to the MB485ETH CG The first time the MB485ETH CG GUI is opened in a browser the IP Address for the gateway will appear as untrusted This will...

Страница 20: ...admin and the Password found on the label of the MB485ETH CG NOTE There is also a QR code in the top right corner of the MB485ETH CG label that shows the default unique password when scanned NOTE A us...

Страница 21: ...t allows the user to select which mode the MB485ETH CG should use NOTE Cookies are used for authentication NOTE To change the web server security mode after initial setup go to Appendix B 5 The sectio...

Страница 22: ...their respective fields If the Private Key is encrypted type in the associated Passphrase Click Save A Redirecting message will appear After a short time the Web Configurator page will open 7 2 2 HTTP...

Страница 23: ...tab on the left side of the screen Click the Network tab that appears to open the Network Settings page A warning message will appear when performing the first time setup click the Exit Registration b...

Страница 24: ...Settings The Common Settings make it possible to choose the primary connection when both Ethernet and Wi Fi Client connections are available NOTE The default Primary Connection is Ethernet Select the...

Страница 25: ...Gateway and Domain Name Server1 2 NOTE If connected to a router set the Default Gateway to the same IP Address as the router Click Update IP Settings then click on System Restart to restart the Gatewa...

Страница 26: ...le DHCP to automatically assign all Wi Fi Client network settings or manually modify the setting using the fields immediately below IP Address Network etc NOTE If connected to a router set the IP gate...

Страница 27: ...cess Point SSID Access Point Password SSID Broadcast and Channel NOTE The default channel is 11 The default IP Address is 192 168 50 1 Click Update Wi Fi Settings then click on the System Restart to r...

Страница 28: ...and hosts local applications for device configuration management as well as maintenance For more information about the SMC Cloud refer to the SMC Cloud Start up Guide 9 1 Choose Whether to Integrate S...

Страница 29: ...that appears and click the Exit Registration button skip to Section 10 to continue MB485ETH CG configuration o To ignore SMC Cloud setup until the next time the MB485ETH CG Web App is opened click a...

Страница 30: ...e manufacturer s support team and follow the instructions below to set up login details The Welcome to SMC Cloud email will appear as shown below NOTE If no SMC Cloud email was received check the spam...

Страница 31: ...elds and click the checkbox to agree to the privacy policy and terms of service NOTE If access to data logs using RESTful API is needed do not include in the password Click Save to save the user detai...

Страница 32: ...rver When first logging onto the MB485ETH CG the Web App will open on the SMC Cloud page NOTE If a warning message appears instead go to Appendix B 7 to resolve the connecton issue Click Get Started t...

Страница 33: ...ls and SMC Cloud account credentials o Enter user details and click Next o Enter the site details by entering the physical address fields or the latitude and longitude then click Next Figure 31 SMC Cl...

Страница 34: ...rrier o Enter Name and Description required then click Next o Enter user credentials and click Register Device Figure 33 SMC Cloud Registration Gateway Details Figure 34 SMC Cloud Registration SMC Clo...

Страница 35: ...ick the Close button and the following screen will appear listing the device details and additional information auto populated by the MB485ETH CG NOTE Update these details at any time by going to the...

Страница 36: ...istration credentials NOTE If the login password is lost see the SMC Cloud Start up Guide for recovery instructions On first login the Privacy Policy window will appear Read the Terms of Service click...

Страница 37: ...2020 Carrier 37 NOTE For additional SMC Cloud instructions see the SMC Cloud Start up Guide Figure 38 SMC Cloud Landing Page...

Страница 38: ...then click Configuration NOTE For information on the System Status button go to Appendix B 8 Then click the Profiles Configuration button to go to the Web Configurator page NOTE For Web App instructio...

Страница 39: ...only visible when the associated protocol is selected NOTE If Modbus TCP IP was selected and is used for the field protocol skip Section 10 3 Device profiles are NOT used for Modbus TCP IP Ensure tha...

Страница 40: ...re shown below the configuration parameters The Active Profiles section lists the currently active device profiles including previous Web Configurator additions This list is empty for new installation...

Страница 41: ...ings on the device and correspond to the device IP Address and TCP_ID Section 4 3 3 Then press the Submit button to add the Profile to the list of devices to be configured Repeat this process until al...

Страница 42: ...et Node_ID For example if the desired Device Instance for the device 1 is 50 001 and the following is true Device 1 has a Node ID of 1 Device 2 has a Node ID of 22 Device 3 has a Node ID of 33 Then pl...

Страница 43: ...he steps outlined in Section 10 1 to access the MB485ETH CG Web Configurator At the bottom left of the page click the Clear Profiles and Restart button Once restart is complete all past profiles disco...

Страница 44: ...and complete the installation Connect a standard Cat 5 Ethernet cable between the user s PC and MB485ETH CG Double click on the FS Toolbox Utility and click Discover Now on the splash page Check for...

Страница 45: ...G into the web browser or use the MB485ETH CG Toolbox to connect to the MB485ETH CG Click on Diagnostics Button then click on view and then on connections If there are any errors showing on the Connec...

Страница 46: ...e device was listed under the Web Configurator Active Profiles Section 10 3 No COMS on Modbus TCP IP side To fix check the following o Visual observations of LEDs on the MB485ETH CG Appendix A 4 o Che...

Страница 47: ...nterface to support for evaluation PWR The power light should always show steady green when connected to a functioning power source RX The RX LED will flash when a message is received on the serial po...

Страница 48: ...Diagnostics page via one of the following methods o Open the MB485ETH CG FS GUI page and click on Diagnostics in the Navigation panel o Open the MB485ETH CG Toolbox software and click the diagnose ic...

Страница 49: ...Capture is complete email it to technical support The Diagnostic Capture will accelerate diagnosis of the problem Ensure that MB485ETH CG Toolbox is loaded onto the local PC Otherwise download the MB...

Страница 50: ...e Start Diagnostic button o Wait for the capture period to finish and the Diagnostic Test Complete window will appear Step 2 Send Log o Once the diagnostic test is complete a zip file is saved on the...

Страница 51: ...Instructions For instructions on how to reset a MB485ETH CG back to its factory released state see ENOTE MB485ETH CG Next Gen Recovery Appendix A 8 Internet Browser Software Support The following web...

Страница 52: ...o the following a Click on Setup b Click on File Transfer c Click on the General tab 5 In the General tab click on Choose Files and select the web img file extracted in step 1 6 Click on the orange Su...

Страница 53: ...2020 Carrier 53 Appendix B 3 Mounting The MB485ETH CG can be mounted using the DIN rail mounting bracket on the back of the unit Figure 53 DIN Rail Din Rail Bracket...

Страница 54: ...54 2020 Carrier Appendix B 4 Physical Dimension Drawing Figure 54 MB485ETH CG FPA W44 Dimensions R1 Serial Port Power Port Wi Fi Antenna Socket R2 Serial Port...

Страница 55: ...endix B 5 Change Web Server Security Settings After Initial Setup NOTE Any changes will require a MB485ETH CG reboot to take effect From the FS GUI page click Setup in the Navigation panel Figure 55 F...

Страница 56: ...1 Change Security Mode Click Security in the Navigation panel Click the Mode desired If HTTPS with own trusted TLS certificate is selected follow instructions in Section 7 2 1 Click the Save button Fi...

Страница 57: ...available if the security mode was previously setup as HTTPS with own trusted TLS certificate Click Security in the Navigation panel Click the Edit Certificate button to open the certificate and key...

Страница 58: ...very Instructions document For ProtoNode FPC N54 or MB485ETH CG recovery instructions see the MB485ETH CG Next Gen Recovery document If the default unique password is lost then the unit must be mailed...

Страница 59: ...ord o User details are hashed and salted NOTE The password must meet the minimum complexity requirements An algorithm automatically checks the password entered and notes the level of strength on the t...

Страница 60: ...ncil icon next to the desired user to open the User Edit window Once the User Edit window opens change the User Security Group and Password as needed Click Confirm Once the Success message appears cli...

Страница 61: ...rrier 61 Appendix B 6 2 1 Delete Users Click the trash can icon next to the desired user to delete the entry When the warning message appears click Confirm Figure 62 Setup Users Figure 63 User Delete...

Страница 62: ...algorithm automatically checks the password entered and notes the level of strength on the top right of the Password text field NOTE If a gateway in the field is updated to a secure gateway the passwo...

Страница 63: ...rk settings by clicking the Settings tab and then click the Network tab o Check with the site s IT support that the DNS settings are setup correctly o Ensure that the MB485ETH CG is properly connected...

Страница 64: ...tivity and device alert level The color of the button represents the status of one to all three systems Green Normal status Yellow Warning status Red Alarm status Click on the System Status Button to...

Страница 65: ...pe SMA Encryption TKIP WPA AES Figure 66 Specifications Appendix C 1 1 Compliance with UL Regulations For UL compliance the following instructions must be met when operating MB485ETH CG The units shal...

Страница 66: ...same as the Modbus RTU registers for the serial device If this point list is needed contact technical support The Modbus TCP IP node address of the device is also the same as the Modbus RTU node addr...

Страница 67: ...T_count_f Timer AI 4 U16_XXX 003 4 3 X01 3 nvoTimer_XXX SNVT_count_f Flame AI 5 U16_XXX 004 4 3 X01 4 nvoFlame_XXX SNVT_count_f Logstat AI 6 U16_XXX 005 4 3 X01 5 nvoLogstat_XXX SNVT_count_f Sysmins A...

Страница 68: ...U32_XXX 022 4 3 X02 22 nvoLko10BrCy_XXX SNVT_count_f Op_Control BI 27 Bit_XXX 032 4 3 X03 32 nvoOpControl_XXX SNVT_switch Aux_1 BI 28 Bit_XXX 033 4 3 X03 33 nvoAux1_XXX SNVT_switch Aux_2 BI 29 Bit_XX...

Страница 69: ...XXX SNVT_count_f Sensor 1 Measured Raw Value AI 30 Flt_XXX 029 4 3 X01 29 nvoSen1MsRaw_XXX SNVT_count_f Sensor 2 Measured Raw Value AI 31 Flt_XXX 030 4 3 X01 30 nvoSen2MsRaw_XXX SNVT_count_f Sensor 3...

Страница 70: ...I 93 Flt_XXX 092 4 3 X01 92 nvoFt7ErCod_XXX SNVT_count_f Fault 7 Time Of Fault Occ AI 94 Flt_XXX 093 4 3 X01 93 nvoFt7TimFlt_XXX SNVT_count_f Fault 7 Date Of Fault Occ Day Hour AI 95 Flt_XXX 094 4 3 X...

Страница 71: ..._count_f Sensor 5 Cut Out Value AI 146 Flt_XXX 145 4 3 X01 145 nvoSn5CtOtVl_XXX SNVT_count_f Sensor 5 Margin Alarm Value AI 147 Flt_XXX 146 4 3 X01 146 nvoSn5MgAlVl_XXX SNVT_count_f Sensor 5 Limit Ala...

Страница 72: ...NT_SAFE BV 29 Bit_XXX 022 4 3 X03 22 nvoOUT_IntSf_XXX SNVT_switch OUT_BIT7 BV 30 Bit_XXX 023 4 3 X03 23 nvoOUT_Bit7_XXX SNVT_switch OUT_LO_FIRE BV 31 Bit_XXX 024 4 3 X03 24 nvoOUT_LoFir_XXX SNVT_switc...

Страница 73: ...0 Lo Oil Press BV 91 Bit_XXX 040 4 3 X03 40 nvoYZLoOlPrs_XXX SNVT_switch YZ300 Lo Atom Media BV 92 Bit_XXX 041 4 3 X03 41 nvoYZLoAtMed_XXX SNVT_switch YZ300 Lo Gas Press BV 93 Bit_XXX 042 4 3 X03 42 n...

Страница 74: ...AV 142 U16_XXX 117 4 3 X01 117 nvoL1Modmax_XXX SNVT_count_f LAG 2 Lag Mode AV 143 U16_XXX 118 4 3 X01 118 nvoL2LagMode_XXX SNVT_count_f LAG 2 Start Delay AV 144 U16_XXX 119 4 3 X01 119 nvoL2StrtDel_X...

Страница 75: ...I 16 AI_XXX 018 4 3 X01 18 nvoHoursRun_XXX SNVT_count_f Burner Status AI 17 AI_XXX 019 4 3 X01 19 nvoBrnrStat_XXX SNVT_count_f Trim AI 18 AI_XXX 020 4 3 X01 20 nvoTrim_XXX SNVT_count_f Setpoint AI 19...

Страница 76: ..._f Engineers Key 052 AI 80 AI_XXX 102 4 3 X01 102 nvoEngKey052_XXX SNVT_count_f Engineers Key 053 AI 81 AI_XXX 103 4 3 X01 103 nvoEngKey053_XXX SNVT_count_f Engineers Key 054 AI 82 AI_XXX 104 4 3 X01...

Страница 77: ...ey115_XXX SNVT_count_f Engineers Key 116 AI 144 AI_XXX 166 4 3 X01 166 nvoEngKey116_XXX SNVT_count_f Engineers Key 117 AI 145 AI_XXX 167 4 3 X01 167 nvoEngKey117_XXX SNVT_count_f Engineers Key 118 AI...

Страница 78: ...AI 208 AI_XXX 230 4 3 X01 230 nvoEngKey180_XXX SNVT_count_f Engineers Key 181 AI 209 AI_XXX 231 4 3 X01 231 nvoEngKey181_XXX SNVT_count_f Engineers Key 182 AI 210 AI_XXX 232 4 3 X01 232 nvoEngKey182_...

Страница 79: ...XXX SNVT_count_f Fault Log Item 05 Day AI 1045 Log_XXX 044 4 3 X02 44 nvoF05Day_XXX SNVT_count_f Fault Log Item 05 Hour AI 1046 Log_XXX 045 4 3 X02 45 nvoF05Hour_XXX SNVT_count_f Fault Log Item 05 Min...

Страница 80: ..._f Fault Log Item 13 Day AI 1109 Log_XXX 108 4 3 X02 108 nvoF13Day_XXX SNVT_count_f Fault Log Item 13 Hour AI 1110 Log_XXX 109 4 3 X02 109 nvoF13Hour_XXX SNVT_count_f Fault Log Item 13 Minute AI 1111...

Страница 81: ...21 Fault Num AI 1169 Log_XXX 168 4 3 X02 168 nvoF21FltNum_XXX SNVT_count_f Fault Log Item 21 Condition AI 1170 Log_XXX 169 4 3 X02 169 nvoF21Cond_XXX SNVT_count_f Fault Log Item 21 Year AI 1171 Log_X...

Страница 82: ...18 nvoLckotHst4_XXX SNVT_count_f LOCKOUT_HISTORY_5 AV 31 U16_XXX 019 4 3 X01 19 nvoLckotHst5_XXX SNVT_count_f LOCKOUT_HISTORY_6 AV 32 U16_XXX 020 4 3 X01 20 nvoLckotHst6_XXX SNVT_count_f DEVTYP AV 33...

Страница 83: ...38 4 3 X03 38 nvoE3Aux5_XXX SNVT_switch E300 Aux 6 BV 69 Bit_XXX 039 4 3 X03 39 nvoE3Aux6_XXX SNVT_switch E300 Low Water BV 70 Bit_XXX 040 4 3 X03 40 nvoE3LoWtr_XXX SNVT_switch E300 Gas Selected BV 71...

Страница 84: ...SNVT_switch OUT_MTFI BV 15 Bit_XXX 016 4 3 X03 16 nvoOUT_MTFI_XXX SNVT_switch OUT_Main Fuel BV 16 Bit_XXX 017 4 3 X03 17 nvoOUT_MnFl_XXX SNVT_switch OUT_Pilot BV 17 Bit_XXX 018 4 3 X03 18 nvoOUT_Pilo...

Страница 85: ...em Seconds AI 32 U16_XXX 031 4 3 X01 31 nvoSysSec_XXX SNVT_count_f Operating Frequency MCU 1 AI 33 U16_XXX 032 4 3 X01 32 nvoOpFrqMCU1_XXX SNVT_count_f Operating Frequency MCU 2 AI 34 U16_XXX 033 4 3...

Страница 86: ...ut History 8 Reason Code AI 71 U16_XXX 070 4 3 X01 70 nvoLH8RsnCd_XXX SNVT_count_f Lockout History 8 Burner State AI 72 U16_XXX 071 4 3 X01 71 nvoLH8BrnSt_XXX SNVT_count_f Lockout History 8 Burner Min...

Страница 87: ...istory Data AI 21 U16_XXX 016 4 3 X01 16 nvoLsFlHtDat_XXX SNVT_count_inc_f 2nd to Last Fault History Type AI 22 U16_XXX 017 4 3 X01 17 nvo2FlHtTyp_XXX SNVT_count_inc_f 2nd to Last Fault History Data A...

Страница 88: ...XXX 018 4 3 X02 18 nviSrvCdPs19_XXX SNVT_count_inc_f Servo Cmd Position at Speed 20 AV 20 Wrt_XXX 019 4 3 X02 19 nviSrvCdPs20_XXX SNVT_count_inc_f Servo Cmd Position at Speed 21 AV 21 Wrt_XXX 020 4 3...

Страница 89: ...53 nviSrvCdPs54_XXX SNVT_count_inc_f Servo Cmd Position at Speed 55 AV 55 Wrt_XXX 054 4 3 X02 54 nviSrvCdPs55_XXX SNVT_count_inc_f Servo Cmd Position at Speed 56 AV 56 Wrt_XXX 055 4 3 X02 55 nviSrvCd...

Страница 90: ...8 nvoAT_Setpnt_XXX SNVT_swtich REMOTE BI 24 DI_XXX 009 4 3 X03 9 nvoRemote_XXX SNVT_swtich ABOVE_LIMIT BI 25 DI_XXX 010 4 3 X03 10 nvoAbvLimit_XXX SNVT_swtich EXT2 DI BI 26 DI_XXX 011 4 3 X03 11 nvoE...

Страница 91: ...AI 29 S16_XXX 028 4 3 X01 28 nvoIR_Pnt_5_XXX SNVT_count_inc_f IR DATA POINT 6 AI 30 S16_XXX 029 4 3 X01 29 nvoIR_Pnt_6_XXX SNVT_count_inc_f IR DATA POINT 7 AI 31 S16_XXX 030 4 3 X01 30 nvoIR_Pnt_7_XXX...

Страница 92: ...ED AI 93 S16_XXX 094 4 3 X01 94 nvoB_IRSenEn_XXX SNVT_count_inc_f FILE B UV SENSOR ENABLED AI 94 S16_XXX 095 4 3 X01 95 nvoB_UVSenEn_XXX SNVT_count_inc_f FILE B IR GAIN SWITCH AI 95 S16_XXX 096 4 3 X0...

Страница 93: ...SNVT_count_inc_f LEARNT AVG ON FFT FOR IR POINT 21 AI 158 S16_XXX 159 4 3 X01 159 nvoLnOnIR21_XXX SNVT_count_inc_f LEARNT AVG ON FFT FOR IR POINT 22 AI 159 S16_XXX 160 4 3 X01 160 nvoLnOnIR22_XXX SNV...

Страница 94: ...5_XXX SNVT_count_inc_f LEARNT AVG OFF FFT FOR UV POINT 6 AI 215 S16_XXX 216 4 3 X01 216 nvoLnOffUV6_XXX SNVT_count_inc_f LEARNT AVG OFF FFT FOR UV POINT 7 AI 216 S16_XXX 217 4 3 X01 217 nvoLnOffUV7_XX...

Страница 95: ...gital Input 13 BI 30 Srv_XXX 029 4 3 X01 29 nvoCurDI13_XXX SNVT_switch Current Digital Input 14 BI 31 Srv_XXX 030 4 3 X01 30 nvoCurDI14_XXX SNVT_switch Current Digital Input 15 BI 32 Srv_XXX 031 4 3 X...

Страница 96: ...count_inc_f Servo 7 Current Position AI 94 Srv_XXX 093 4 3 X01 93 nvoSv7CurPos_XXX SNVT_count_inc_f Servo 8 Command AI 95 Srv_XXX 094 4 3 X01 94 nvoSv8Cmd_XXX SNVT_count_inc_f Servo 8 Data Length AI 9...

Страница 97: ..._f Lockout History 3 Day AI 157 Srv_XXX 156 4 3 X01 156 nvoLH3_Day_XXX SNVT_count_inc_f Lockout History 3 Year AI 158 Srv_XXX 157 4 3 X01 157 nvoLH3_Year_XXX SNVT_count_inc_f Lockout History 4 Operati...

Страница 98: ...NVT_count_inc_f Lockout History 10 Profile Position AI 220 Srv_XXX 219 4 3 X01 219 nvoLH10PrPos_XXX SNVT_count_inc_f Lockout History 10 Error Code AI 221 Srv_XXX 220 4 3 X01 220 nvoLH10ErrCd_XXX SNVT_...

Страница 99: ...ofile 3 Max Modulation AI 279 Srv_XXX 278 4 3 X01 278 nvoPrf3MxMod_XXX SNVT_count_inc_f Profile 4 Name AI 280 Srv_XXX 279 4 3 X01 279 nvoPrf4Name_XXX SNVT_count_inc_f Profile 4 Max Modulation AI 281 S...

Отзывы: