8

LED AND HORN PATTERNS

LIGHTS

GREEN light ON

YELLOW light blinks once per
minute.

YELLOW light blinks during horn
ramp-up.

RED blinks 4 times right after
horn sounds.

YELLOW light flashes 2 times per
minute after horn beeps.

YELLOW light flashes 3 times per
minute after horn beeps.

YELLOW light flashes constantly
after horn beeps.

RED light flashes 4 times right
after horn.

RED light flashes 3 times every
10 seconds.

RED light flashes 1 time every
10 seconds.

SMART BUTTON KEY

Quick push activates a local
Push-to-Test sequence.

Press and RELEASE button
before you hear the third chirp.
The system will perform a single
local test cycle.

Quick press will eliminate the
low-battery warning for about 10
hours.

Smart Button WILL NOT silence
the low battery chirp! Replace
battery immediately!

Press to check the alarm again.
Replace alarm if it remains in the
fault condition.

Quick press activates CO Reset.

Quick press erases the CO
latched signal.

Quick press activates Smart
Quiet™ Trigger Alarm locator for
Model FADCM and GCM alarms.

THE SMOKE/CO ALARM 

PROBLEM

SOLUTION

Horn beeps twice a
minute and YELLOW
light flashes.

Push the Smart Button to allow alarm to reset and self
test. If fault signal continues, alarm is no longer providing
protection and must be replaced.

The alarm beeps once a
minute and YELLOW
light flashes.

The battery needs to be replaced. Turn off power and
replace the battery. (See “REPLACING THE BATTERY” in
“TESTING AND MAINTENANCE”.) Push the Smart Button
to temporarily quiet the low battery signal for 10 hours.

The horn beeps once,
then two beeps, then
three beeps, pauses, and
then sounds the full
alarm when using the
Smart Button to test.

The alarm is operating properly. The Firex patented Horn
Ramp-Up feature lets you start the test sequence and
move away from the unit before the full alarm horn
sounds.

Alarm sounds; 
no hazard present.

Take Emergency Safety Actions in all alarm situations! If
no hazard proves to be present: Test the alarm to check
for proper functioning. Clean the alarm. (See TESTING
AND MAINTENANCE.) Check that the alarm is placed
properly. (See AGENCY RECOMMENDATIONS FOR
ALARM PLACEMENT.)

For Technical Support:
PH: (800) 445-8299
Email: technical [email protected]
Website: www.icca.invensys.com/firex

YELLOW light blinks during horn
ramp-up.

RED blinks 4 times right after
horn sounds.

Press and HOLD button. 
The system will perform a single
local test cycle, then repeat the
interconnect test until you release
the button.

WARNING

DO NOT disconnect the battery or AC power

to quiet an unwanted alarm. This will remove
your protection. 
Use Quick Quiet™ False Alarm Control™ by
pushing the Smart Button.

Both RED lights flash with horn.

Quick press activates False
Alarm Control™.

Both RED lights flash 3 times
every 10 seconds.

Both RED lights flash 1 time
every 10 seconds.

Quick press activates Smart
Quiet™ Trigger Alarm locator for
smoke and heat alarms.

REPLACE OR RETURN THE ALARM IF THE PUSH-TO-TEST FUNCTION DOES
NOT OPERATE PROPERLY AFTER FOLLOWING THE PROCEDURES OUTLINED
ABOVE

(see 

Where to send your alarm for service

on page 10).

Содержание FADCM

Страница 1: ...uld this occur You must still test the alarm weekly to verify proper horn operation Trigger Alarm Locator TAL Most interconnect tests trigger all alarm horns simultaneously for the duration of the test This unique system alternates between a 10 second ALL ON cycle and a 50 second cycle where only the initiating alarm is sounding Alarm Controlled Interconnect Test In an interconnected system this f...

Страница 2: ...red by the California State Fire Marshal Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows a smoke detector installed in each separate sleeping area in the vicinity but outside the bedrooms and heat or smoke detectors in the living rooms dining rooms bedrooms kitchens hallways attics furnace rooms closet...

Страница 3: ...rms can only sound their alarms when they detect CO gas They do not sense heat flame or any gas other than carbon monoxide CO This alarm is designed to give audible warning that a dangerously high level of CO is present You must respond immediately to the CO alarm horn Smoke and CO alarms have limitations This alarm is not foolproof and is not war ranted to protect lives or property from fire Smok...

Страница 4: ...d 3 Interconnected AC Only and AC DC Alarms 1 Remove the mounting plate Hold the alarm and turn the mounting plate clockwise to separate it from the back of the alarm 2 Hold the mounting plate against the ceiling or wall in the desired position and use a pencil to trace the inside of the mounting slots 3 Use a 3 16 5mm drill bit to drill through the center of the outlines you made in Step 2 4 Inse...

Страница 5: ...OT PRESENT FOR ANY REASON AC POWERED SMOKE CO OR HEAT ALARMS WILL NOT OPERATE THIS ALARM SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION S STANDARD 72 National Fire Protection Association One Batterymarch Park Quincy MA 02269 Connect CO and smoke alarms to a single dedicated AC branch circuit If local codes do not permit such a wiring configuration or connection be ...

Страница 6: ... a false alarm TO TEMPORARILY SILENCE AN ALARM NOTE These features temporarily quiet alarms but do not disable the sensor When you push the Smart Button during an alarm one of three things will happen 1 All interconnected alarms are silenced This means you pushed the button on the unit that actually triggered alarm Quick Quiet False Alarm Contro l 2 One unit still sounding an alarm the rest are si...

Страница 7: ...ving power and functioning properly 3 Alarm interconnect circuit problem Replace and retest 4 On DC battery powered interconnected alarms remove alarm from mounting bracket and check that the connector plug is securely attached 5 On an interconnected series with both AC and AC DC powered units wiring may have been improperly connected Have wiring checked by a licensed electrician Retest all alarms...

Страница 8: ...G AND MAINTENANCE Push the Smart Button to temporarily quiet the low battery signal for 10 hours The horn beeps once then two beeps then three beeps pauses and then sounds the full alarm when using the Smart Button to test The alarm is operating properly The Firex patented Horn Ramp Up feature lets you start the test sequence and move away from the unit before the full alarm horn sounds Alarm soun...

Страница 9: ...ds the CO poisoning because they stay in the home where CO is present As CO levels rise the symptoms become more extreme At low levels people will suffer headaches and mild nausea At higher levels unconsciousness heart failure and even death can occur The following symptoms are related to CARBON MONOX IDE POISONING and should be discussed with ALL members of the household Mild Exposure Slight head...

Страница 10: ...r this combination alarm Doing so will void your warranty If the alarm is not operating properly see Troubleshooting If you must return an alarm under warranty send the alarm in a well padded envelope with postage prepaid a note describing the nature of the difficulty and proof of date of purchase to In U S In Canada Invensys Controls Americas Invensys Controls Americas 28C Leigh Fisher Blvd Servi...

Отзывы: