Firegear FPB-25SFPSBR21AWS-N Скачать руководство пользователя страница 1

Pro Series Fire Pit Burners with

All Weather Electronic Ignition System (AWS)

Installation and Operating Instructions

IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS 

DO NOT  ATTEMPT TO INSTALL OR OPERATE THIS APPLIANCE

DO NOT DISCARD.  THIS MANUAL 

HAS IMPORTANT OPERATING AND 

MAINTENANCE INSTRUCTIONS.  

LEAVE WITH THE HOMEOWNER

.

Warning:

  For Outdoor Use Only

INSTALLATION PRECAUTION

 

This system requires a minimum 18-square inches (per side) of cross ventilation. 

Failure to provide proper ventilation will void the warranty.

Natural Gas Models

Propane Gas Models

Description

FPB-26DPSBR21AWS-N

FPB-26DPSBR21AWS-P

26” Round Disc with 21” Pro Brass Burner

FPB-29DPSBR21AWS-N

FPB-29DPSBR21AWS-P

29” Round Disc with 21” Pro Brass Burner

FPB-34DPSBR21AWS-N

FPB-34DPSBR21AWS-P

34” Round Disc with 21” Pro Brass Burner

FPB-25SFPSBR21AWS-N FPB-25SFPSBR21AWS-P 25” Square Disc with 21” Pro Brass Burner
FPB-30SFPSBR21AWS-N FPB-30SFPSBR21AWS-P 30” Square Disc with 21” Pro Brass Burner
FPB-34SFPSBR21AWS-N FPB-34SFPSBR21AWS-P 34” Square Disc with 21” Pro Brass Burner

Round Disc

MODEL:
SERIAL #:

PN#90191

Square Disc

“PRO SERIES”

Содержание FPB-25SFPSBR21AWS-N

Страница 1: ...oss ventilation Failure to provide proper ventilation will void the warranty Natural Gas Models Propane Gas Models Description FPB 26DPSBR21AWS N FPB 26DPSBR21AWS P 26 Round Disc with 21 Pro Brass Bur...

Страница 2: ...gas to the appliance 2 Extinguish any open flame 3 If odor continues keep away from the appliance and immediately call your gas supplier or fire department DANGER WARNING Do not store or use gasoline...

Страница 3: ...nce This drying out period should be no less than 30 minutes Continue monitoring the flame from distance to ensure that all popping has ceased before fully enjoying the fire CAUTION TABLE OF CONTENTS...

Страница 4: ...ning Spurs Note Flex line size and proper gas pipe sizing will also affect Btu s As a result your Btu s may vary slightly from Table 2 specifications Fig 2 Clearance to Combustibles Not to be used in...

Страница 5: ...nection of the stainless steel flex gas line not supplied with the fire feature 5 Do not place an LP tank inside any fire pit enclosure Locate all Liquid Propane LP tanks outside the enclosure 6 To pr...

Страница 6: ...required for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper...

Страница 7: ...re bag includes the key valve part shown below in Fig 5 Note Check for any gas leaks after gas is connected and turned ON Fig 4 Shows carton contents Note Round pan was illustrated for this drawing CA...

Страница 8: ...the flame is a safe and reasonable height to not pose a risk to people or property Note The Firegear Pro Series brass burners DO NOT USE a primary main burner orifice like a standard stainless steel b...

Страница 9: ...d inside the enclosure due to the wire length limitations The power cord is 3 feet long the 30VDC leads to the valve are 3 feet long See Fig 5 Fig 7 Example of a single fire feature install with power...

Страница 10: ...detail enables the ability to remove the pan disc to service valve system Flex Frame Optional ON OFF Controls Note Actual power supply must be 10 feet or more from the pool or spa DETAIL Pool Control...

Страница 11: ...NOT PLACE ROCK OVER TOP OR UNDER THE PILOT SCREEN COVER The screen must be free of any debris to ensure proper lighting of burner and good flame sense See Fig 10 Cover the burner completely with media...

Страница 12: ...LP gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance READ ALL LIGHTING INSTRUCTIONS BEFORE ATTEMPTING TO LI...

Страница 13: ...REV A Page 13 FPB Pro Series Fire Pits with AWS System AWS REPLACEMENT PARTS GOE 30DCV OUT 1 4 3 2 5 6 7 8 9 10 Items are not to scale...

Страница 14: ...4 inch 1 FG SPBG 7 Pilot Burner Cage hood 1 FG PBC 8 Thermopile for primary pilot assembly 1 FG TP 9 Hot Surface Ignition for pilot burner assembly item 2 1 FG HSI 10 Heat Shield 1 FG HEATSHIELD 11 Ro...

Страница 15: ...f for some reason someone connected 120VAC power directly to the gas valve the controller inside the valve box will be damaged It this happens a burned electrical smell might be present Connector Not...

Страница 16: ...loosen the thermopile from the pilot assembly and slide it out If it will not slide out because is it too tight then it will need to be replaced Debris Debris can get trapped inside the screen of the...

Страница 17: ...fect Remove some of the fire glass media from the burner to see if this fixes the problem Gas Leak Natural Gas is lighter than air therefore when released into the atmosphere it rises If you have a Na...

Страница 18: ...n using paver blocks or other non combustible enclosures Glass Windshields See catalog for a windshield to fit your application Shut Off Valves Model 01 387 OD Flare x FIP Model 01 487 OD Flare x FIP...

Страница 19: ...5 YEAR WARRANTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WA...

Страница 20: ...REPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WAR...

Страница 21: ...repair the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and repl...

Страница 22: ...pany to assume for it any other obligation or liability in connection with the sale installation use removal return or replacement of its equipment and or such representation are binding Firegear Outd...

Страница 23: ..._____ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 Wh...