background image

REV. A             Page 3

FPB Pro Spur Burners Fire Pits with MT System

Specifications

4

Gas Pipe Sizing

5

Removing Fire Pit from Carton

6

Preparation for Non-Combustible Structure

7

     Hard Piping to Fire Pit

7

    Cross Ventilation Requirements

7

Installation into an Approved Enclosure

8

    Requirements

8

    Installing Key Valve 

8-9

    Typical Installation Drawing

9

Operation

10

    

Lighting Instructions

10

Replacement Parts

11

Replacement Parts List

12

Fire Pit Maintenance/ Trouble Shooting

13

Optional Accessories

13

TABLE OF CONTENTS

NOTE:

  An exterior lid/cover is not required but highly recommended when the fire pit is not in use. Even though 

fire pits are designed for outdoors they are not impervious to all weather 

conditions if not protected.  See the accessory page for information and sizes.  

All media (i.e. lava rock, lava stones, lava boulders and fire glass) has the potential of thermal 

spalling.  This is a process that may occur when media is wet and moisture gets trapped inside of 

the material due to rapid temperature differences.  When this happens the media has the potential 

to crack or “pop” outside the fireplace.

WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE

The use of a cover can lessen the impact of thermal spalling; however, heavy rains, high 

humidity and the presence of moisture may still cause the media to pop.

ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE 

Extra caution should be taken when lighting a fireplace when heavy rains, high humidity and 

moisture are present.  Light the fireplace; leave the area allowing any moisture in the media to 

dissipate.  We strongly recommend that during this drying out time that you monitor the fire feature 

from a distance.  This drying out period should be no less than 30 minutes.  Continue monitoring 

the flame from distance to ensure that all popping has ceased before fully enjoying the fire. 

Congratulations! 

 You have just purchased a Firegear Outdoors “Pro Series” fire pit that includes a

304 Stainless Steel burner pan with a Brass Burner. The Brass Burners come in two diameter sizes,

14-inch, and 21-inch models. Each burner leg incorporates individual injectors that take the place of

a standard main burner orifice. Each burner is unique in the fact that the14-inch burner has three

(3) injectors per leg and the 21-inch burner has four (4) injectors per leg. These injectors provide a

unique flame pattern that differs from a typical steel burner.

Содержание FPB-19RPSBR14MT-N

Страница 1: ...provide proper ventilation will void the warranty Natural Gas Models Propane Gas Models Description FPB 19RPSBR14MT N FPB 19RPSBR14MT P 19 Round Pan with 14 Pro Brass Burner FPB 25RPSBR21MT N FPB 25RP...

Страница 2: ...ff gas to the appliance 2 Extinguish any open flame 3 If odor continues keep away from the appliance and immediately call your gas supplier or fire department DANGER WARNING Do not store or use gasoli...

Страница 3: ...lace WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rains high humidity and the presence of moisture may stil...

Страница 4: ...r Size D Ground Level E Side Wall F Combustible Ceiling G Combustible Floor FPB 19RPSBR14MT N FPB 19RPSBR14MT P 2 19 Rd 14 8 36 120 18 FPB 25RPSBR21MT N FPB 25RPSBR21MT P 2 25 Rd 21 8 36 120 18 FPB 29...

Страница 5: ...s required for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have prop...

Страница 6: ...ontents The box includes a flex gas line key valve flange key and flared fitting with nipple Inspect for any damage or missing parts See Fig 4 Install the flared fitting and nipple into the bottom of...

Страница 7: ...ten 2 Extend the gas supply system using minimum of black iron pipe or an approved flexible gas line from existing house supply This can be accomplished by teeing off or tapping into a gas line connec...

Страница 8: ...outdoor use only Not approved for any indoor use 9 This fire pit is designed to have lava rock completely covering the spur burner so that the burner is not visible Do not cover more than 1 above the...

Страница 9: ...s Supply Key Valve Side View Det a i l Fig 7 Typical installation NOTE Key valve and flexible gas lines are supplied Gas shut off is not supplied Note A 1 x 2 black iron or galvanized coupler nipple n...

Страница 10: ...connection before each use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This ap...

Страница 11: ...REV A Page 11 FPB Pro Spur Burners Fire Pits with MT System MT REPLACEMENT PARTS 1 2 6 3 8 4 9 10 Drawings not to scale O N O F F 7 5...

Страница 12: ...use a ventilated cover overtop of your fire pit to protect it from humid rainy weather conditions when not in use Heavy rains downpours could affect the fire pit operation if not covered if this occur...

Страница 13: ...Web Site www firegearoutdoors com 800 966 8126 See Firegear Outdoors catalog for other accessories E STOP Gas shut off valve with mechanical timer and emergency shut off Models ESTOP1 0H 1 hour timer...

Страница 14: ...D S Fitting Fire Pit Disc Inlet Gas Supply Expanded View of Match Throw MT Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threads...

Страница 15: ...VE 5 YEAR WARRANTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME...

Страница 16: ...FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR...

Страница 17: ...o repair the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and rep...

Страница 18: ..._______ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6...