REV. A Page 3
FPB Pro Spur Burners Fire Pits with MT System
Specifications
4
Gas Pipe Sizing
5
Removing Fire Pit from Carton
6
Preparation for Non-Combustible Structure
7
Hard Piping to Fire Pit
7
Cross Ventilation Requirements
7
Installation into an Approved Enclosure
8
Requirements
8
Installing Key Valve
8-9
Typical Installation Drawing
9
Operation
10
Lighting Instructions
10
Replacement Parts
11
Replacement Parts List
12
Fire Pit Maintenance/ Trouble Shooting
13
Optional Accessories
13
TABLE OF CONTENTS
NOTE:
An exterior lid/cover is not required but highly recommended when the fire pit is not in use. Even though
fire pits are designed for outdoors they are not impervious to all weather
conditions if not protected. See the accessory page for information and sizes.
All media (i.e. lava rock, lava stones, lava boulders and fire glass) has the potential of thermal
spalling. This is a process that may occur when media is wet and moisture gets trapped inside of
the material due to rapid temperature differences. When this happens the media has the potential
to crack or “pop” outside the fireplace.
WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE
The use of a cover can lessen the impact of thermal spalling; however, heavy rains, high
humidity and the presence of moisture may still cause the media to pop.
ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE
Extra caution should be taken when lighting a fireplace when heavy rains, high humidity and
moisture are present. Light the fireplace; leave the area allowing any moisture in the media to
dissipate. We strongly recommend that during this drying out time that you monitor the fire feature
from a distance. This drying out period should be no less than 30 minutes. Continue monitoring
the flame from distance to ensure that all popping has ceased before fully enjoying the fire.
Congratulations!
You have just purchased a Firegear Outdoors “Pro Series” fire pit that includes a
304 Stainless Steel burner pan with a Brass Burner. The Brass Burners come in two diameter sizes,
14-inch, and 21-inch models. Each burner leg incorporates individual injectors that take the place of
a standard main burner orifice. Each burner is unique in the fact that the14-inch burner has three
(3) injectors per leg and the 21-inch burner has four (4) injectors per leg. These injectors provide a
unique flame pattern that differs from a typical steel burner.