Firegear FPB-19RBSMT-N Скачать руководство пользователя страница 14

REV. C  Page 14

MT Burning Spur Fire Pits

FIREGEAR LIMITED WARRANTY -

 2021

Firegear Outdoors hereby warrants to the end user that products will be free from material and workmanship 

defects that prevent safe and correct operation of the product. The warranty commences from date of sale to 

the end user for the following period: 

CONSUMER RESIDENTIAL APPLICATIONS – MANUFACTURED AFTER 12/02/2019 

BURNER SYSTEMS, BURNERS, COMPONENTS AND ACCESSORIES 

• LIFETIME WARRANTY ON CONSTRUCTION AND MANUFACTURER DEFECTS

• LIFETIME WARRANTY - STAINLESS STEEL BURNERS AND PANS

• LIFETIME WARRANTY - BRASS BURNERS

• FIVE (5) YEAR WARRANTY - GAS VALVE, SPARK IGNITER, PILOT ASSEMBLIES

• FIVE (5) YEAR WARRANTY - AWS ELECONITC IGNITION SYSTEMS (24VAC, 30 VDC)

• FIVE (5) YEAR WARRANTY - TFS/TMSI ELECTRONIC COMPONENTS

• FIVE (5) YEAR WARRANTY – MT COMPONENTS (KEY VALVE)

• FIVE (5) YEAR WARRANTY - REFRACTORY GAS LOG SETS

• FIVE (5) YEAR WARRANTY - READY TO FINISH/ANF FIRE PIT ENCLOSURES

• FIVE (5) YEAR WARRANTY – SKYTECH MANUACFTURED OPTIONAL CONTROLS

OUTDOOR FIREPLACE – KALEA BAY 

• LIFETIME WARRANTY - CONSTRUCTION AND MANUFACTURER DEFECTS

• LIFETIME WARRANTY - STAINLESS STEEL COMPONENTS

• FIVE (5) YEAR WARRANTY - GAS VALVE, PILOT ASSEMBLY, POWER SUPPLY, CONTROLS

• FIVE (5) YEAR WARRANTY – SKYTECH MANUACFTURED OPTIONAL CONTROLS

SANCTUARY SERIES – GFRC FIRE FEATURES 

• THREE (3) YEAR WARRANTY - GFRC STRUCTURE

• REFER TO THE APPROPRIATE BURNER SYSTEM FOR WARRANTY

WARRANTY COVERS MANUFACTURING DEFECTS OR STRUCTURAL FAILURE. SMALL STRESS CRACKS AND SURFACE 

CRAZING ARE A NATURAL OCCURRENCE IN GFRC PRODUCTS AND NOT COVERED BY WARRANTY

READY TO FINISH/ANF ENCLOSURES 

• FRAME – LIFETIME WARRANTY ON CONSTRUCTION AND MANUFACTURER DEFECTS

ACCESSORIES 

• LIFETIME WARRANTY - CONSTRUCTION AND MANUFACTURER DEFECTS

• LIFETIME WARRANTY - STAINLESS STEEL COMPONENTS (LIDS, STAINLESS STEEL COVERS)

• ONE (1) YEAR WARRANTY – ESTOP1-OH, ESTOP2-5H WINDSHIELDS, HOSES AND REGULATORS

Содержание FPB-19RBSMT-N

Страница 1: ...escription FPB 19RBSMT N 19 Round Stainless Pan with 16 Burning Spur FPB 25RBS22MT N 25 Round Stainless Pan with 22 Burning Spur FPB 29RBS22MT N 29 Round Stainless Pan with 22 Burning Spur FPB 33RBS31MT N 33 Round Stainless Pan with 31 Burning Spur FPB 20SBSMT N 20 Square Stainless Pan with 16 Burning Spur FPB 26SBS22MT N 26 Square Stainless Pan with 22 Burning Spur FPB 32SBS31MT N 32 Square Stain...

Страница 2: ...fire department WARNING Do not store our use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicinity of this or other appliances WARNING Do not leave unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation a...

Страница 3: ...GHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rains high humidity and the presence of moisture may still cause the media to pop ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE Extra caution should be taken when lighting a fireplace when heavy rains high humidity and moisture are present Light the fireplace leave ...

Страница 4: ... 13 0 WC 3 23 kPa Normal Inlet 7 0 WC 1 74 kPa 11 0 WC 2 73 kPa Table 3 Gas Pressures Model N Natural Gas A Pan Depth B Min Max Install Opening C Inside Pan D Ground Level E Side Wall F Combustible Ceiling G Combustible Floor Burner Size FPB 19RBSMT N 2 19 20 19 8 36 96 18 16 FPB 25RBS22MT N 2 25 27 25 8 36 96 18 22 FPB 29RBS22MT N 2 29 30 29 8 36 96 18 22 FPB 33RBS31MT N 2 33 35 33 8 36 120 18 31...

Страница 5: ...anual shut off valve at the exterior house wall If pipe is to pass through a foundation or house wall make sure to re seal the area around the pipe with weather sealant 3 The primary gas shut off not supplied will require a male flared fitting to enable connection of the stainless steel flex gas line supplied with the fire pit see Fig 5 page 7 IMPORTANT Installation of Natural or LP gas should be ...

Страница 6: ...r outdoor use only Not approved for any indoor use 9 This fire pit is designed to have Firegear Outdoors lava rock completely covering the Spur burner so that the burner is not visible Do not cover more than 1 above the top of the covered burner When purchasing lava rock use 1 diameter as a base to fill the burner pan 10 Gas lines and fittings must be installed in to the non combustible structure ...

Страница 7: ... Valve Primary Gas Supply Key Valve Side View Det a i l Fig 5 Typical installation NOTE Key valve and flexible gas lines are supplied Gas shut off is not supplied Note A 1 x 2 black iron or galvanized coupler nipple not supplied can be used as a spacer between the manual valve and the valve flange to add additional support to hold the manual key valve in place Key Valve Flange Non Combustible Wall...

Страница 8: ...fore each use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance LIGHTING INSTRUCTIONS Key Fig 7 Inserting Key into Valve O N O F F Fig 6 Key Valve Face Butane L...

Страница 9: ...REV C Page 9 MT Burning Spur Fire Pits MT REPLACEMENT PARTS 1 2 6 3 8 7 5 4 9 10 Drawings not to scale O N O F F 11 12 13 14 8a ...

Страница 10: ...ce Propane Gas 250 000 Btu s 1 OAS LP12 9 10 24 x 1 2 Type F Screw 304 SS not shown 4 10759 10 Key Valve 1 BVL2S 11 12 Inch Chrome Key 1 KEY PC 12 12 Chrome Cover Plate 1 CVR BVL2CP 13 NPT Male to Male Flare Fitting 1 U1 8D S 14 NPT Female to Male Flare Fitting 1 U3 8D S Item Description Qty Part Number MT REPLACEMENT PARTS 1 The fire pit should be inspected and cleaned before initial use at least...

Страница 11: ...ig 10 or 11 A 90 elbow is not provided with the kit All NPT pipe threads must be sealed with approved gas Teflon tape or pipe compound Check for any gas leaks before presuming normal operation after conversion is complete CAUTION Ensure there is ventilation under the burner to provide fresh air for air shutter orifice Burner Pan GAS FLOW x 5 inch Nipple 113SS4 D5 OAS LP Orifice Flared Fitting U3 8...

Страница 12: ...rainage for water and proper ventilation to dry out ACCESSORIES The following accessories are available from your local Firegear dealer distributor Each accessory comes with a separate installation manual Read each instruction thoroughly before installing Stainless Round Lid for 19 33 Pits Models LID 19R2 LID 25R2 LID 29R2 LID 33R2 Stainless Square Lid for 20 38 Pits Models LID 20S LID 26S LID 32S...

Страница 13: ... S U1 8D S Fitting Fire Pit Pan Inlet Gas Supply Expanded View of Match Throw MT Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threads not flared fittings Ensure all connections are tight and check for gas leaks before and after assembly is complete Not Supplied ...

Страница 14: ... WARRANTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS FIVE 5 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTION...

Страница 15: ...E KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS SANCTUARY SERIES GFRC FIRE FEATURES THREE 3 YEAR WARRANTY GFRC STRUCTURE REFER TO THE APPROPRIATE BURNER SYSTEM FOR WARRANTY WARRANTY COVERS MANUFACTURING DEFECT...

Страница 16: ...r the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firegear is not responsible for Issues related to gas or electrical installation The Limited Warranty is voided if not assembled installed and operated as intended This Limited Warranty does not cov...

Страница 17: ... units Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation or exclusion may not apply to you We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale installation use removal return or replacement of its equipment and or such representation are binding Firegear Outdoors 14520 ...

Страница 18: ... Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of media are you using __________________ 7 Review the troubleshooting section in the installation manual 8 What are the symptoms Please be prepared to explain 9 Be prepared to send photos to us when...