Firegear FG-H-2110SS Скачать руководство пользователя страница 1

REV. C  Page 1

DO NOT DISCARD.  THIS MANUAL 

HAS IMPORTANT OPERATING AND 

MAINTENANCE INSTRUCTIONS.  

LEAVE WITH THE HOMEOWNER

.

MODEL:
SERIAL #:

Outdoor Fire Pit H-Burners & Kits

H-Burner Only

Description

H-Burner Kit

Description

Input Rating

FG-H-2110SS 21” H-Burner FG-H-2110SSK 21” H-Burner Kit

75,000 Btu’s

FG-H-2710SS 27” H-Burner FG-H-2710SSK 27” H-Burner Kit 100,000 Btu’s
FG-H-3310SS 33” H-Burner FG-H-3310SSK 33” H-Burner Kit 125,000 Btu’s
FG-H-4510SS 45” H-Burner FG-H-4510SSK 45” H-Burner Kit 150,000 Btu’s
FG-H-5710SS 57” H-Burner FG-H-5710SSK 57” H-Burner Kit 175,000 Btu’s
FG-H-6910SS 69” H-Burner FG-H-6910SSK 69” H-Burner Kit 200,000 Btu’s

FG-H-8110SS 81” H-Burner FG-H-8110SSK 81” H-Burner Kit 225,000 Btu’s

FG-H-9310-SS 93” H-Burner FG-H-9310SSK 93” H-Burner Kit 250,000 Btu’s

Installation and Operating Instructions

IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS 

DO NOT  ATTEMPT TO INSTALL OR OPERATE THIS APPLIANCE

Warning:

  For Outdoor Use Only

INSTALLATION PRECAUTION

Fire pit burners require a minimum 18-square inches (per side) of cross ventilation 

in an enclosure. Failure to provide proper ventilation can void the warranty.

PN#90119

These fire pit burners are manufactured from the factory for Natural gas only.  If you intend using LP gas then 

you must purchase a LP conversion kit.  See Table of Contents for LP converstion kit information.

Содержание FG-H-2110SS

Страница 1: ...69 H Burner FG H 6910SSK 69 H Burner Kit 200 000 Btu s FG H 8110SS 81 H Burner FG H 8110SSK 81 H Burner Kit 225 000 Btu s FG H 9310 SS 93 H Burner FG H 9310SSK 93 H Burner Kit 250 000 Btu s Installat...

Страница 2: ...DANGER WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicinity...

Страница 3: ...e feature WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rains high humidity and the presence of moisture may...

Страница 4: ...10 72 x 12 8 36 120 18 7 8 1 FG H 8110SS FG H 8110SSK 2 3 81 x 10 84 x 12 8 36 120 18 7 8 1 FG H 9310SS FG H 9310SSK 2 3 93 x 10 96 x 12 8 36 120 18 7 8 1 Disclaimer Btu listings are based on 7 0 WC...

Страница 5: ...se a Propane tank less than 100lbs capacity IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier This appliance must be isolated from the...

Страница 6: ...e sizes required for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will hav...

Страница 7: ...provide ventilation to prevent moisture and provide an outlet for gas in the case of a gas leak 8 CAUTION A minimum of 18 square inches of cross ventilation opposite sides is required to keep the encl...

Страница 8: ...the pan See Fig 4 then install the OAS and U3 8D S to the nipple connect inlet gas line as shown in Fig 5 7 8 to 1 Inch Center Hole Fig 4 Minimum center clearance hole in burner pan ALL H BURNER MODE...

Страница 9: ...Outdoors See replacement parts list in manual for model numbers INSTALLING KEY VALVE INSTALLATION OF LAVA ROCK MEDIA INTO BURNER PAN Install lava rock into the burner pan Ensure the lava rock is a 1 i...

Страница 10: ...y Key Valve Side View Det a i l Fig 5 Typical installation NOTE Key valve and flexible gas lines are supplied Gas shut off is not supplied Note A 1 x 2 black iron or galvanized coupler nipple not supp...

Страница 11: ...use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when ope...

Страница 12: ...H Burner Kit REV C Page 12 REPLACEMENT PARTS 2 3 Drawings not to scale 5 2a 4 O N O F F 4a 6 1 7...

Страница 13: ...Burner 10619 2 2a OAS Orifice Air Shutter for Natural Gas or LP Gas Fire Pits Refer to Table 2 on page 4 3 1 2 Flex Gas Line 28 inch Length used with all kits 1 T200 9898 28 4 Key Valve 1 BVL2S 4a Chr...

Страница 14: ...ce See Fig 11 below for details Note It is acceptable to install a 90 elbow if necessary to run the gas line the opposite direction see Fig 12 or 13 A 90 elbow is not provided with the kit All NPT pip...

Страница 15: ...to operate NOTE If a combustible type cover is used over the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard 5 Over time stainless steel parts can dis...

Страница 16: ...Y REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRU...

Страница 17: ...BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTECH...

Страница 18: ...fect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firege...

Страница 19: ...consequential damages so this limitation or exclusion may not apply to you We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale ins...