Firegear BCOL-18NG Скачать руководство пользователя страница 8

8

Firegear, LLC., -IM-138 2/2012

L. Lighting Instructions-Match Light

Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev B • 12/05

14

P.  Lighting Instructions- Match Light

Asphyxiation Risk

Gas-burning appliances produce smoke and 

carbon monoxide gas during operation.

•  The damper 

must

 be open

•  The chimney must draw properly
These fumes can be harmful if not vented 

properly.

WARNING

1.  STOP!

 Read the safety information previously listed above.

2.  Turn gas control manual valve to the full “OFF” position.

3.  Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” 

in the safety information above on this label. If you don’t smell gas, go to the next step.

4.  Place a lit match on the surface of the burning embers. Do not hold match in hand.

5.  Turn gas control manual valve to the full “ON” position.

6.  If appliance will not operate, follow the instructions “TO TURN OFF GAS TO APPLIANCE” and call your service 

technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

LIGHTING INSTRUCTIONS

A.

  This appliance has a manually lighted burner and must be lit by hand. When lighting the burner, follow these 

instructions exactly.

B.  BEFORE LIGHTING 

smell all around the appliance area for gas. Be sure to smell next to the floor because some 

gas is heavier than air and will settle on the floor.

 

WHAT TO DO IF YOU SMELL GAS

 

•  Do not try to light any appliance.

 

•  Do not touch any electrical switch; do not use any phone in your building.

 

•  Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

 

•  If you cannot reach your gas supplier, call the fire department.

C.

  Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect 

the appliance and to replace any part of the control system and any gas control that has been under water.

D.  Use only your hand to push in or turn the gas control handle. Never use tools. If the handle will not push in or turn 

by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in fire or 

explosion.

Turn manual  gas control handle to “OFF” position. Do not force.

FOR YOUR SAFETY READ BEFORE LIGHTING

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING! 

IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT 

CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

(Place lit match in ember bed before turning on valve)

(Located in wall or floor 

near fireplace)

Valve Key

Valve

Содержание BCOL-18NG

Страница 1: ...mell gas Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING HOT DO NOT T...

Страница 2: ...me to the Firegear LLC family of appliance products Congratulations Homeowner Reference Information Model Name Date purchased installed Serial Number Location on appliance Dealership purchased from Dealer phone Notes We recommend that you record the following pertinent information about your gas log set A Design and Installation Considerations The Gas Log Hearth Kit consists of the following Log S...

Страница 3: ...ed and cleaned by qualified professionals Firegear LLC recommends that NFI or CSIA certified professionals or technicians under the direction of certified professionals conduct a minimum of an NFPA 211 Level 2 inspection of the chimney Replace component parts of the chimney and fireplace as specified by the professionals Ensure all joints are properly engaged and the chimney is properly secured Do...

Страница 4: ...ly be installed in a solid fuel burning fireplace with the flue damper clamped open according to Tables 1 and 2 The fireplace must be constructed of non combustible material The minimum permanent free opening in square inches that must be provided by the fireplace chimney or damper to vent the flue gases is provided in Tables 1 and 2 If the free opening is smaller than the specified area do not us...

Страница 5: ...nimum Fireplace Dimensions Log Set Front Opening Depth Height Rear Width Natural BTU BCOL18 27 in 16 in 18 in 19 in 40 000 BCOL24 34 in 20 in 18 in 22 in 73 000 BCOL30 40 in 20 in 18 in 29 in 80 000 BCOL318 32 in 23 in 22 in 21 in 76 000 BCOL324 34 in 23 in 22 in 22 in 86 000 BCOL330 40 in 23 in 22 in 29 in 86 000 H Inspect the Appliance and Components Remove the contents from burner box Attached ...

Страница 6: ...here the flame is blue This will achieve the desired realism The gas burns at the point of the least resistance In case of an uneven flame pattern it may be necessary to adjust the materials in the pans using an object such as a screwdriver to achieve the desired effect Place desired amount of lava granules on the floor of the fireplace DO NOT ALLOW THE GRANULES TO COME IN CONTACT WITH THE FLAMES ...

Страница 7: ... If necessary seek expert advice Do not operate this appliance Cleaning Periodic examination and cleaning of the venting system of the fireplace should be done before initial use and at least annually by a qualified agency M Cleaning and Maintenance Instructions Always remember Do not place any combustible material near the appliance Do not place any paper trash or other material on the log set or...

Страница 8: ...these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas s...

Страница 9: ...ose my fireplace damper to get more heat from my vented gas log set No Vented gas logs are designed to be operated with the damper in the fully opened position This gas log set produces carbon monoxide gas The damper must be removed or clamped fully open using the C clamp provided with the set My gas logs make a whistling noise when I burn them What causes this This behavior is normally caused by ...

Страница 10: ...24 30 BCOL 3 18 24 30 Description of Part 18in 24 in 30 in Qty 1 Burner Pan Grate Assembly BPA 300 18 BPA 300 24 BPA 300 30 1 2 Burner Pan Grate Assembly 3 Tier Only BPA 300 33 BPA 300 35 BPA 300 40 1 3 Gas Line Connector FT 18 FT 24 FT 30 1 4 Damper Clamp 10 1065 10 1065 10 1065 1 3 4 2 1 ...

Отзывы: