Firefly DE500 Скачать руководство пользователя страница 1

 

User Manual for Firefly Microscope DE500                       

Version: 1.2 

 

D

IGITAL 

M

ICROSCOPE

 

 

                           

 

 
 

THANKS FOR SELECTING A FIREFLY MICROSCOPE 

To take full advantage of this product’s advanced capabilities,   

and to properly and safely use this product, please read the manual carefully. 

 

DE500  

User Manual

Содержание DE500

Страница 1: ... DE500 Version 1 2 DIGITAL MICROSCOPE THANKS FOR SELECTING A FIREFLY MICROSCOPE To take full advantage of this product s advanced capabilities and to properly and safely use this product please read the manual carefully DE500 User Manual ...

Страница 2: ...ly Globaland its vendors All rights are reserved The software is protected by U S and international copyright laws and international treaty provisions applicable worldwide Under such laws the licensee is entitled to use the copy of the software incorporated with this instrument as intended in the operation of the product in which it is embedded The software may not be copied decompiled reverse eng...

Страница 3: ...Power the Device On 11 Recommended holding position 12 Brightness Adjustment 12 Using the image capture control 12 Using Focus 13 Function as a laryngoscope 13 Standby and Remove device 14 Launch the Software Application 15 Viewing the Images 15 Tool bars 16 Control tool bars 16 Image tool bars 16 Device Tool bars 17 Maintenance and service 18 Cleaning recommendation 18 Recycling the system compon...

Страница 4: ...ast and Sharpness for desired applications System Requirements The Firefly Microscope System requires a user PC system running Windows XP Service Pack 2 or later operating system a viewing screen and a PC with an available USB 1 1 or 2 0 port Intended use The Firefly Microscope System is intended to allow inspection of the external ear ear canal and tympanic membrane under magnification A secondar...

Страница 5: ...ro These reference images are not intended for medical or other diagnostic purposes Caution A caution statement in this manual identifies condition or practice which if not corrected or discontinued immediately could lead to equipment failure equipment damage or data loss In order to obtain optimum performance and ensure patient safety thoroughly read this manual Do not use the Firefly Microscope ...

Страница 6: ...s product complies with current required standards for electromagnetic interference and should not present problems to other equipment or be affected by other devices As a precaution avoid using this device in close proximity to other equipment Do not apply alcohol chemicals or water to the lens Any liquids entering the optical assembly will damage internal components ...

Страница 7: ...2 CHECK LIST Before starting check that all the following items have been included with your product If anything is missing contact your dealer Microscope x 1pc Clip attached to scope x 1 pc USB cable x 1 pc Software Application CD Specula S M L x 5 sets ...

Страница 8: ...8 User Manual for Firefly Microscope DE500 Version 1 2 NOMENCLATURE ...

Страница 9: ...ERATION Setting up the microscope with specula Only accepts original specula qualified for use with Firefly microscopes Plug the specula into the round concave guide in front To remove Simply pull to unplug the specula Ensure a tight fit for proper operation ...

Страница 10: ...nation the optional Field of View F O V extender may be attached The F O V extender can be ordered separately Plug the F O V Extender into the round concave guide in front of the microscope Plug the specula into the round concave guide in front of the F O V Extender To remove Simply pull to unplug the specula Ensure a tight fit for proper operation ...

Страница 11: ...are application following the instructions provided with the installation CD Connect to PC Connect the Firefly Microscope to the PC s USB port Power the Device On Towards the rear of the device a switch allows the user to power the device ON and to activate the LEDs OFF Switch off the devic LED1 Switch the device ON and enable 4 LEDs LED2 Enable 8 LEDs for maximum illumination ...

Страница 12: ... and allows lens control The index finger is still free to rotate and adjust the focus wheel as shown Brightness Adjustment On left rear side of the microscope a knob allows the user to control the brightness of the LEDs Backward Turn Decrease Brightness Forward Turn Increase Brightness Using the image capture control Press and release the Capture button to capture image frames The system will gen...

Страница 13: ...the focus wheel can be turned to the left see below If a larger field of view is required the microscope can be moved farther away and the wheel turned to the right Default Position Match the scale 50 to arrow mark Function as a laryngoscope The Firefly Microscope can b e transformed into a laryngoscope by removing the specula and attaching a spatula on the clip Free Focus Rotate wheel to fine tun...

Страница 14: ... device through Windows above the m can be unplugged from the PC s USB port Using this sequence will avoid transient voltages from potentially causing hardware damage To temporarily turn off or remove the device slide the power button to the OFF position Th device must also be turned off through the Windows operating system On your Microsoft Windows Deskto Computer in the left pane Double click ...

Страница 15: ...th Firefly Microscope The Microscope communicates with the PC thr the USB compact receiver The user can configure the video properties review live images capture images record video clips and perform a variety of powerful measurement on functions features of FireflyPro are shown below e Images Pro software controls your Firefly ough and documentati The main ...

Страница 16: ... Redo the previous Rotation Text Comment and Zoom ROI Select region of interest ROI on live video stream Undo ROI Revoke ROI selection Rotation Rotate live video 0 90 180 270 Mirror Mirror live video horizontally Flip Flip live video vertically Text Comment Add text layer on image Image Measure Launch image measurement application Zoom Zoom in live video up to 300 Zoom Zoom out live video down to ...

Страница 17: ...fly Microscope DE500 Version 1 2 Device Tool bars Icon Icon Name Function Description Device Connect Refresh image device connection Select available image devices such as Microscope Select a video format default 640x480 YUY2 ...

Страница 18: ... Union on Waste Electronic and Electrical Equipment WEEE If this product is contaminated this directive does not apply For more specific disposal information contact Customer Service Outside the EU When the product and its components reach end of life recycle the product according to national state and local regulations Accessories REF Description FY MU 180 USB Cable 180cm length FY MU 300 USB Cab...

Страница 19: ...th the problem Where ible use the arton and packing materials In ber It is recommended that all s or damage to the product are the responsibility of the Unauthorized repairs will void the warran product fails to function properly or if you need assistance service or spare parts c Firefly reseller contacting your reseller try to duplicate the problem and check all accessories to ensure that they Pr...

Страница 20: ...Dim 1 6 inches Pow Width 4 0 cm er USB 5VDC 150mA Prot water ection against ingress of IPXØ Operating conditions Tem Rela Altit Ship perature 10 C to 40 C 50 F to 104 F tive humidity 30 to 75 noncondensing ude 700 to 1060 hPa ping and storage conditions Tem C to 49 C 4 F to 120 F Rela Safe perature 20 tive humidity 95 noncondensing max ty Compliance FCC CE and RoHS compliant Patent Patent Pending ...

Страница 21: ...ND REPLACEMENT AS SET FORTH IN THIS WARRANTY STATEMENT ALL EXPRESS AND IMPLIED WARRANTIES FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES AND CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN TIME TO THE TERM OF THE LIMITED WARRANTY PERIOD REFLECTED ON YOUR PACKING SLIP OR INVOICE NO WARRANTIES WHETHER EXPRESS OR IMPLIED WILL APPLY AFTER THE LIMI...

Страница 22: ...alternatives that are il How will you fix my product THE MAXIMUM AMOUNT FOR WHICH WE ARE RE warranty period is not extended if a warranted product or any parts are repaired or replaced FireFly Global may change the availability of limited hardware warranties at its discretion but any changes will not be retroactive defective in materials or workmanship If FireFly Gl n y u contact our authorized re...

Страница 23: ...ry restarting the software application again Q4 Why is there no image displayed on FireflyPro image windows Answer a Please verify whether the device is connected properly b Please switch the Microscope device OFF and back to either LED1 or LED2 Q5 The Microscope is connected to the PC but why can it not be used Answer a Make sure the FireflyPro software is installed completely and properly b Plea...

Страница 24: ...ream and does not meet the minimum standards set forth in the instructions Please use faster system Q8 What to do if the FireflyPro software application crashes Answer If the system crashes disconnect the USB data cable and switch off the Microscope Re boot the PC and after system reboot reconnect the Microscope switch on and restart the FireflyPro application ...