Accessories
The following is a list of accessories for FC503
and FC506 control panels with a description of
the main features. For further information about
these accessories, refer to the instructions supplied
with the accessories or download them from the
FC500IP IP module
The FC500IP is an IP module which is used to
connect the FC503 or FC506 fire panel to a LAN.
The IP Module may be connected to a LAN using
a private IP address or a DHCP address. The same
procedures may be performed using the FireClass
FC500 (FC501_FC503_FC506) Console application,
either through the serial port or the network. With
a public IP address and access to the internet, you
can manage and monitor the control panel from
anywhere in the world.
4B Universal base
The 4B Universal base is for use with the FC460,
FC400, and FC600 series of detectors.
The base may be fixed directly to:
•
British (fixing centers 50 mm) or European
(fixing centers 70 mm) conduit box
•
4B EM Euro Mounting Box
•
The suspended ceiling, through the CTA
adapter
•
Directly to the ceiling
FC460H or FC400H Addressable
heat detector
The FC460H or FC400H detector is intended to plug
into the following:
•
4B 4” Universal Base
•
4B-I 4” Isolator Base
•
FC430SB Low Power Sounder Base
•
FC430LPSB Loop Powered Addressable
Sounder Base
•
FC430LPASB Loop Powered Addressable
Sounder/Beacon Base.
Software within the controller is used to interpret
the returned heat values to raise an alarm or
other appropriate responses according to the
type of detector configured in the FireClass FC500
(FC501_FC503_FC506) Console. The mode of the
detector may be:
•
EN54-5 A1R, rate-of-rise normal ambient
•
EN54-5 A2S, fixed 60
°
C
•
EN54-5 CR, rate-of-rise high ambient
FC460P or FC400P Addressable
optical smoke
The FC460P and FC400P optical smoke detectors
form part of the FC460 and FC400 series
addressable fire detectors.
•
4BI 4” Isolator base
•
4B 4” Universal base
•
FC430SB Low power sounder base
•
FC430LPSB Loop powered addressable
sounder base
•
FC430LPASB Loop powered addressable
sounder beacon base.
Software within the controller is used to interpret
the returned optical and heat values to raise an
alarm or other appropriate response according
to the type of detector configured in the FireClass
FC500 (FC501_FC503_FC506) Console.
FC460PH or FC400PH
Addressable optical smoke &
heat detector
The detector is intended to plug into one of the
following:
•
4B 4” Universal base
•
4B-I 4” Isolator base
•
FC430SB Low power sounder base
•
FC430LPSB Loop powered addressable
sounder base
•
FC430LPASB Loop powered addressable
sounder/beacon base
Software within the controller is used to interpret
the re-turned optical and heat values to raise an
alarm or other appropriate response according
to the type of detector configured in the FireClass
FC500 (FC501_FC503_FC506) Console. The mode of
detector may be:
•
Optical smoke only detector (sensitivity high,
normal, or low)
FC503 and FC506 Addressable Fire Control Panels
73