Fire Sentry SS4-A Скачать руководство пользователя страница 1

                           Model SS4-A/-A2 Optical Fire Detector 

Page i 

Installation and Operations Guide 

 

______________________________________________________________________________________________________________________ 

   Fire  Sentry  Corporation  

Document  No. 1510-007 

– Rev D 

©   Copyright  2009            All  Rights  Reserved 

 

 

 

 

 

 

 

Multi-Spectrum Digital 

Electro-Optical Fire Detector

 

MODEL 

SS4-A/-A2 

(

CENELEC

 

STAND-ALONE RELAY MODE 

or 4-20 mA Output Option 

 

 

Installation Guide 

and 

Operating Manual

 

 

 

Fire Sentry Corporation (FSC) 

 

23311 La Palma Avenue 

 

Tel.:  714-694-2700 

Yorba Linda, California 92887 

Fax:  714-694-2701

 

Содержание SS4-A

Страница 1: ...________________ Fire Sentry Corporation Document No 1510 007 Rev D Copyright 2009 All Rights Reserved Multi Spectrum Digital Electro Optical Fire Detector MODEL SS4 A A2 CENELEC STAND ALONE RELAY MOD...

Страница 2: ...ure Analysis FireBusI FireBusII FirePic FirePicII FirePicIII FirePix FirePicture FSC Fire Sentry Corporation Fire Sentry Corp FSX All FSX Nomenclature Variations such as FS2 FS2X FS3 FS3X FS4 FS4X FS5...

Страница 3: ...onduit Installation 6 2 1 3 Wiring Recommendations 6 2 1 4 Power Supply Considerations 6 2 2 Installation Procedure 6 2 2 1 Configuring and Wiring Detectors 6 2 2 2 Removing Detector From Its Enclosur...

Страница 4: ...t gasoline pan fire with a 120 degree 60 degrees from the axis conical field of view Their microprocessor based algorithms FirePic SnapShot and Tri Mode Plot assure time programmable alarm verificatio...

Страница 5: ...potential fire source preferably along the axis of the vision cone Install enough Detectors to completely eclipse the fire hazardous area Assure accessibility for the Detector lens cleaning as well as...

Страница 6: ...nated without power cycling of the device 1 4 2 Detection Range and Field of View The SS4 A A2 detection range is field adjustable between 15 and 60 feet in 15 feet increments to an industrial standar...

Страница 7: ...d This concludes the verification process If the presence of the fire is not established the Fire Relay will remain energized unless Non Latching mode is set In case a subsequent fire is detected the...

Страница 8: ...after repair or maintenance involving wiring or module replacement after periodic maintenance or after lens contamination has been identified 1 6 2 Automatic Testing Automatic SLR BIT Built In Test th...

Страница 9: ...l for all applications requiring a Class I Div 1 Explosion Proof rating 2 1 3 Wiring Recommendations To prevent intermittent connections Fire Sentry Corporation recommends using junction boxes Install...

Страница 10: ...sert the cables into the metal enclosure base through one of the conduit openings Refer to Figure 6 b Connect the 24 Volt DC power supply wires to pins 1 and 4 of the J1 or J2 connector observing the...

Страница 11: ...4 V DC J2 pin 4 24 V DC RTN J2 pin 1 4 20 mA output J5 pin 4 4 20 mA RTN J1 pin 1 The fire Alarm and fault relays of a Detector equipped with the MA420 4 Module are not usable However the Detector s V...

Страница 12: ...o the standoffs b If necessary clean the Detector sensors and windowed cover per instructions of Section 3 2 c Securely screw down the metal enclosure top windowed cover and tighten the Allen head tam...

Страница 13: ..._______________________________________________________________________________________________ Fire Sentry Corporation Document No 1510 007 Rev D Copyright 2009 All Rights Reserved 4 86 4 26 2 95 2 0...

Страница 14: ..._________________________________________________________________________________ Fire Sentry Corporation Document No 1510 007 Rev D Copyright 2009 All Rights Reserved 2 09 4 66 1 10 0 67 4 38 2 40 3...

Страница 15: ...of the housing cover If the fault has not been eliminated after re assembly and powering up for 10 to 15 minutes factory service may be necessary f Relay Fault The Detector faults if one of its Relay...

Страница 16: ...safety precautions CAUTION Model SS4 A A2 Detector modules and its components are susceptible to permanent damage due to electrostatic discharge ESD Do NOT handle a module without adequate grounding p...

Страница 17: ...Connection to an optional interface unit for viewing FirePic and TriMode Plot 4 Power 24 Volts DC J2 DETECTOR POWER OUT PIN 1 DC Return or Ground 2 and 3 RS 485 Connection to an optional interface un...

Страница 18: ...f Verify is enabled then the Verify Relay will de energize approximately 10 seconds after it energizes If Verify is disabled then the Fire Relay s will de energize approximately 10 seconds after it en...

Страница 19: ...ring capability through the Detector s RS485 connections The Kit includes an Interface Box a PC software diskette an RS485 and RS232 cables and a 120 VAC 12 VDC charger Optional 220 VAC 12 VDC charger...

Страница 20: ...Cleaning 12 Enclosure 9 LEDs 3 Maintenance Schedule 12 Pinout 14 Pinouts 7 Status 3 Wiring 7 14 Detector Fault High Temperature 12 Input Voltage 12 No Power 12 Relay 12 Self Checking 12 ESD 6 FireBus...

Отзывы: