Warranty Information 

Fire Sentry Corporation warrants its Products against defects in material and workmanship under normal use 
and  service  for  a  period  of 

U

three  (3)  years

U

  from  the  date  of  shipment  as  described  herein.    Fire  Sentry 

Corporation, at its option, will repair or replace, at no charge, such products found to be defective during the 
warranty period provided that they are returned in accordance with the terms of this warranty.  Replaced parts 
or  boards  are  warranted  for  the  balance  of  the  original  applicable  warranty  period.    All  Replaced  parts  of 
Products shall become the property of Fire Sentry Corporation.  This express limited warranty is extended by 
Fire Sentry Corporation to the original purchaser only and is not assignable or transferable to any other party.  
This  is  the  complete  warranty  for  the  Products  manufactured  by  Fire  Sentry  Corporation.    Fire  Sentry 
Corporation assumes no obligations or liability for additions or modifications to this warranty unless made in 
writing  and  signed  by  an  officer  of  Fire  Sentry  Corporation.    Fire  Sentry  Corporation  does  not  warrant  the 
installation, maintenance or service of its Products.  Fire Sentry Corporation is not responsible in any way for 
ancillary equipment not furnished by Fire Sentry Corporation, which is attached to or used in connection with 
its Product(s), or for operation of the Product(s) with ancillary equipment and all such equipment if expressly 
excluded from this warranty.  This warranty sets 

forth the full extent of Fire Sentry Corporation’s responsibility 

regarding the Products’ repair or replacement at Fire Sentry Corporation’s options, is the exclusive remedy. 

This Warranty is given in lieu of all other Express Warranties, Implied Warranties, including without limitation, 
Implied Warranties  of  Merchantability  and  fitness  for  a  particular  purpose,  are  limited  to  the  duration  of  this 
Limited  Warranty.    In  no  other  event  shall  Fire  Sentry  Corporation  be  liable  for  damages  in  excess  of  the 
purchased  price  of  the  product(s),  for  any  loss  of  use,  loss  of  time,  inconvenience,  commercial  loss,  lost 
profits or savings or other incidental, special or consequential damages arising out of or in connection with the 
use or inability to use such product, to the full extent such may be disclaimed by law. 

THIS WARRANTY DOES NOT COVER: 

1.  Defects  or  damage  resulting  from  use  of  the  Product(s)  in  other  than  its  normal  and  customary 

manner. 

2.  Defects or damage from misuse, accident, or neglect. 

3.  Defects  or  damage  from  improper  testing,  operation,  maintenance,  installation,  alteration, 

modification or adjustment. 

4.  Product(s)  subject  to  unauthorized  Product  modifications,  disassemblies  or  repairs  (including, 

without  limitation,  the  audition  of  the  product  of  non-Fire  Sentry  Corporation  supplied  equipment) 
which  adversely  affect  performance  of  the  Product(s)  to  interfere  with  Fire  Sentry’s  normal 
warranty inspection and testing of the Product(s) to verify any warranty claim. 

5.  Product(s) that have had the serial number removed or made illegible. 

6.  Freight cost to the repair facility. 

7.  A  Product  which  due  to  illegal  or  unauthorized  alteration  of  the  software/firmware  in  the  Product, 

does not function in accordance with Fire Sentry Corporation’s specifications. 

8.  Scratches  or  other  cosmetic  damage  to  Product  surfaces  that  do  not  affect  the  operation  of  the 

Product. 

9.  Normal and customary wear and tear. 

 

Laws in the United States and other countries preserve for Fire Sentry Corporation certain exclusive rights for 
copyrighted  Fire  Sentry  Corporation  software/firmware,  such  as  the  exclusive  rights  to  reproduce  in  copies 
and  distribute  copies  of  such  Fire  Sentry  Corporation  software/firmware.    Fire  Sentry  Corporation 
software/firmware may be used only in the Product(s) in which the software/firmware was originally embodied 
and such software/firmware in such Product(s) may not be replaced, copied, distributed, modified in any way, 
or used to produce any derivative thereof.  No other use including, without limitation, alteration, modification, 
reproduction,  distribution,  or  reverse  engineering  of  such  Fire  Sentry  Corporation  software/firmware  or 
exercise  or  rights  in  such  Fire  Sentry  Corporation  software/firmware  is  permitted.    No  license  is  granted  by 
implication, estoppel or otherwise under Fire Sentry Corporation patent rights or copyrights. 

Содержание FS24X QuadBand Triple IR

Страница 1: ...erved Fire Sentry Corporation FSC 23311 La Palma Avenue Tel 714 671 1100 Yorba Linda California 92887 Telephone 714 694 2700 Fax 714 694 2701 www firesentry com FS24X QuadBand Triple IRTM Multi Spectr...

Страница 2: ...ns such as FS2 FS2X FS2X FS3 FS3X FS3X FS4 FS4X FS4X FS5 FS5X FS5X FS6 FS6X FS6X FS7 FS7X FS7X FS8 FS8X FS8X FS9 FS9X FS9X FS10X FS10X FS11 FS11X FS11X FS12 FS12X FS12X FS14 FS14X FS14X FS15 FS15X FS1...

Страница 3: ...uctions 5 U2 2 Opening the Detector 6 U2 3 Detector Connections 7 U2 4 Installation Practices 8 U2 5 Start Up and Commissioning 10 USECTION 3 OPERATION 12U U3 1 Principle of Operation 12 U3 2 Configur...

Страница 4: ...inum or 316 Stainless Steel enclosure The FS24X Detector electro optical electronics module puck is enclosed in a field replaceable black hard anodized aluminum puck that provides superior ruggedness...

Страница 5: ...nduit Entries Two 2 in NPT or Two 2 25 mm Weight Aluminum 3 lbs 11 oz 1 7 kg approximately Stainless Steel 7 lbs 7 oz 3 4 kg approximately Enclosure Rating IP66 NEMA 4 NEMA 4X Vibration Meets or excee...

Страница 6: ...Spectral Sensitivity 0 4 to 7 0 micron wavelengths QuadBand Triple IR Plus 1 2 5 Hazardous Area Calssifications See Section 4 7 3 on Page 23 Class I Division 1 Groups A B C D Class II Division 1 Group...

Страница 7: ...tor s Sensor Array and Electro Optical Electronics Module Anodized Field Removable Detector Aluminum Module Puck Rugged superior protection against EMI RFI and handling plus easier field installation...

Страница 8: ...ctor may cause the fire to be undetected 4 The Model SM4 is a 316 Stainless Steel Swivel Mount designed for the FSC Detector housing The adapter plate with the two 2 screw holes facing away is attache...

Страница 9: ...se Alcohol or IPA sparingly and a cotton swab 3 There are no serviceable parts inside the Detector puck If the puck is opened up or tampered with all warranties are voided FSX Detector Module puck Fig...

Страница 10: ...ule puck has a six 6 pin and a ten 10 pin keyed removable connector with screw terminal female plugs that connect to the two 2 respective male connectors with analog digital and relay interfaces see F...

Страница 11: ...od wiring practices simplifies installation improves reliability and facilitates maintenance 3 For applications requiring analog digital communications please refer to Section 3 2 of this Instruction...

Страница 12: ...ed properly to the correct length loose wire strands must be removed and each wire must be securely and firmly screwed clockwise in the connector 2 If using conduit ensure a proper conduit seal approp...

Страница 13: ...ng window lens cleanliness terminal wiring integrity actual relay activation and the proper functionality of any other outputs that are used Also since most detectors are installed in a fire alarm sys...

Страница 14: ...red ALARM LED on the face of the Detector slowly move the Test Lamp s boresight to ensure the Detector receives its full intensity UNOTE Practicing this technique may help to optimize testing of the F...

Страница 15: ...SP to accurately distinguish radiant energy from a real fire and a false alarm source s Fire Sentry has developed and refined these complex proprietary and patented WideBand IR algorithms over the las...

Страница 16: ...y Time OFF ON 20 Sec Verify Time OFF OFF EOL Resistor SW2 6 Enabled ON Disabled OFF Alarm Relay SW2 7 Factory default settings are shown with a gray background Energized ON De Energized OFF Fault Rela...

Страница 17: ...l operation the bright Blue LED blinks flashes every 10 seconds See Figure 3 4 for the location of the Blue LED Normal Operation is defined as the Detector with 24 VDC applied and no Alarm or Fault co...

Страница 18: ...ion Over Temperature 110 C or 230 F for the Extended Temperature Version Under Temperature 40 C or 40 F for the Standard Version Under Temperature 50 C or 58 F for the Extended Temperature Version One...

Страница 19: ...in excess of the purchased price of the product s for any loss of use loss of time inconvenience commercial loss lost profits or savings or other incidental special or consequential damages arising o...

Страница 20: ...ss II Groups E F G Class III Approvals FM cFM ATEX IECEx FS24X 211 221 QuadBand Triple IR Detector 110 Filed of View General Applications with Relays 4 20mA Output FireBusII 316 Stainless Steel Enclos...

Страница 21: ...ed by something such as a newly installed pipe or duct storage box parked vehicle etc and its alarm outputs are functioning properly For calibrated testing in compliance with NFPA 72 Codes for flame d...

Страница 22: ...in X 12 in 0 3m X 0 3m 60 feet 18 meters 5 seconds Paper 24 Standard 8 5 x 11 sheets 90 feet 27 meters 8 seconds Silane 1 foot 0 3 meter Plume 15 feet 4 5 meters 5 seconds The following table provides...

Страница 23: ...t 15 24 meters Modulated Sunlight No Alarm 25 feet 7 62 meters Modulated Arcwelding 3 feet 9 inches 1 14 meters Source at 15 feet 4 57 meters Fire at 30 feet 9 14 meters Continuous Arcwelding 3 feet 9...

Страница 24: ...DE and OPERATING MANUAL Fire Sentry Corporation Document No 6178 001 Rev Q Copyright 2011 All Rights Reserved Page 21 4 7 Drawings 4 7 1 Outline and Dimensions Figure 4 3 Outline Dimesional Drawing fo...

Страница 25: ...and Terminal Connections Figure 4 5 Typical Wiring for 4 20mA Sourcing Analog Output Figure 4 6 Typical Wiring for 4 20mA Sinking Analog Output NOTES 1 Cable shield must be grounded at one end only a...

Страница 26: ...9 10 Alarm Fault Input N O Alarm Relay Contacts Fault Relay Contacts N O Note 3 Note 2 Note 4 EOL Note 1 Figure 4 8 Typical Relay Output Wiring for Monitoring Alarm and Fault Contacts on a single two...

Страница 27: ...d OPERATING MANUAL Fire Sentry Corporation Document No 6178 001 Rev Q Copyright 2011 All Rights Reserved Page 24 Drawings continued 4 7 3 Detector Label Drawings Figure 4 9 FS24X 9 Label for Hazardous...

Страница 28: ...larm Immunity 18 Fault Conditions 13 Fault Relay 7 11 13 Features and Benefits 3 FireBusII 11 12 13 15 16 Flame Response Sensitivity 17 UH Hazardous Locations 1 HART Communication 15 16 High Temperatu...

Отзывы: