background image

Technical Manuals Online! - http://www.tech-man.com

Содержание XL-2T

Страница 1: ...XL 2T Security System Owner s Manual FIRE BURGWRY INSTRUMENTS INC N9819 7 97 Technical Manuals Online http www tech man com ...

Страница 2: ...SYSTEM OFF 10 USER CODES ll MISCELMNEOUS COMMANDS l2 TESTING THE SYSTEM l4 RECOMMENDATIONS ON SMOKE DETECTORS l5 EMERGENCY EVACUATION l6 GLOSSARY l7 FCC STATEMENT 21 LIMITATIONS OF THIS AURM SYSTEM 22 LIMITED WARRANTY 24 Page 2 Technical Manuals Online http www tech man com ...

Страница 3: ...the system is READY Green ready light is lit Followed by your user code m m m m The OtiOff arm light and the Stay light will both light REMEMBER You must turn the syetem off if you want to open the door or leave the premises after the exit tima has passed TURNTHESYSTEM ON PERIMETERSENSORS INSTANTMODEAND STAY INSIDE Check to make sure the system is READY Green ready tight is lit lowed by Followed b...

Страница 4: ...ur needs XL4600SM A sutiace mount keypad containing indicator lights for each of the 8 zones areas of protection The door covering the buttons is optional and can be removed 6615 A surface mount keypad containing indcator lights for each of the 8 possible zones areas of protection The XL 2T is listed by Underwriters Laboratories for Household Hre and Burglary appkcations Throughout this manual the...

Страница 5: ...into my system Both Buttons must be pressed st the same time to sctivate the aleti The buttons you press depend on which type of keypad you have Your installer will show you how to activate these emergency keys The keys for LED style keypads are shown below BUTTONS DESCRIPTION Right _ 9 Lefi _ l 3 Cente _ t Buttons on XL 4600SM keypad only Page 5 Technical Manuals Online http www tech man com ...

Страница 6: ...Yes No If No of user 13 is not assigned for door strike then any user can ativate the door stdke Only Turns System On Yes If No Ambush Duress Code Yes If No Master Users mn Add Change or Erase other user codes Monitoring Station Information Awount Telephone Page 6 Technical Manuals Online http www tech man com ...

Страница 7: ...rence sheet for the time that has been set for your system NOT READY If the system is not ready to be armed the READY light will be off and the Zone lights will show which zone or zones are not ready The zone fights indicate the following conditions or the display will show as follows Faat Blink Alarm Slow BlinWLow Intensity Bypass Slow Pulse Trouble Solid On Not Ready Example If the Ready fight i...

Страница 8: ...eck to make sure the system is ready when raady press m Followed by your user code unn If successful the OtiOff arm light and the Stay tight will be lit or the display shows REMEMBER You must turn the system off if you want to open the door or leave the premises after the exit time haa passed TURN THE SYSTEM ON PERIMETER SENSORS INSTANT MODE AND STAY fNSIDE In fNSTANT STAY mode the parimeter potii...

Страница 9: ...ress the Bypass Button followed by your user code and then the zone number l 7 to be bypassed m Followed byyour usercode rlmmr ZONE If the Quick Bypass feature has been enabled by the installer the user code is not required when bypassing zones NOTE Bypassed zones are not protected when the system is turned on After the bypass command has been accepted the keypad will sound one long beep and the z...

Страница 10: ...when the system was on or if a trouble condition exists they will display on the zone indcator lights as follows Faat Btink Alarm Slow BlinWLow Intensity Bypass slow Pulse Trouble Solid On Not Ready or the display shows Burgla Alarms will sound a steady sound at tha keypad s and fire alarms will generate a pulsing sound Important If an intrusion has taken place while you were away do not enter unt...

Страница 11: ...u may also have chosen to resewe one user code that is only allowed to turn the system on This code will not be able to turn the system off DELETE A USER CODE To delete a user press the Code button followed by the 4 digit master user code then the user number then press to delete For example to delete user 3 do the following Master User C e User 10 to delete NOTE User 1 the master usar cannot be d...

Страница 12: ...f always requires a vatid User Code Press then 1 QUICK FORCED ON If programmed by your installer Quick Forced On allows you to turn the bu rglar portion of your alarm system on to the away mode bypassing all zones that are not ready Press then 2 NOTE A va d user code ia still required to turn the system off NOTE TMs feature is disabled on UL installations QUICK BYPASS If you hava quick bypass prog...

Страница 13: ... 1 or 2 code hr hrJ mini rein The English read out keypad will prompt you for the required entries user code is not required if so programmed by installer DOOR STRIKE VIEW TIME SET TIME To acfiiate door strikes Press then 9 user code Door where the door number is as follows 1 2 l m Note that ths installer may have aeaigned user 13 as the only user that can perform the door etrike function 3 user 1...

Страница 14: ...kup standby battery the following procedure should be followed 1 Unplug the transformer from the AC outlet by removing the restraining screw which secures the transformer to the wall Note the screw is not present on the models sold in Canada 2 Obsewe that the AC indicator fight on the keypad goes off 3 Activate your alarm by performing the above SYSTEM TEST Remember to contact your Central Station...

Страница 15: ...ate alaaping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl epacea and unfiniahad attics In addition the NFPA recommends that you install heat or smoka detectors in the living room dining room bedroom s kitchen hallway s attic furnace room utility and storage rooms basemerlta and attached garagea o 0 LIV...

Страница 16: ...cate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes in every room Assure that all bedroom doors are shut while you are asleep This will prevent deadly smoka from entering while you escape Try the door If the door is hot chack your alternate escape route If the door is cool open it cautiously Be prepared to slam the door shut if smoka or hea...

Страница 17: ...ond when selected doors are opaned when the burglary protection is off or disarmed Once programmed by your installer you can turn chime on and off with 6 DISARMED See ON OFF DURESS Duress is a system feature the you may have programmed into your system If someone should force you to turn your system off you would use the special Duress user code and the system would turn off and it would also send...

Страница 18: ... detectors temperature sensors floo water sensors and carbon monoxide gas detectors SILENT CONDITION Most types of alarms and troubles alert you with the keypad sounder and the sirens horns or speakers located in your premises The intent is to advise you of the alarm or trouble and allow you to respond promptly The audible sounds also let an intruder know that they have baen detected and will hope...

Страница 19: ...NOTES Page19 Technical Manuals Online http www tech man com ...

Страница 20: ...NOTES Page 20 Technical Manuals Online http www tech man com ...

Страница 21: ...s The user or installer may find the following booklet prepared by the Federal Communication Commission helpful interference HandbooW This booklet ia available from the U S Government Printing Offica Washington DC 20402 The ussr shall not make any changes or modifications to the equipment unlese authorized by the installation Inatructiona or User s Manual Unauthofizad changee or modifications coul...

Страница 22: ...uch ae in chimneys in walls or roofs or on the other side of closed doors Smoke detectors also may not sense a fire on another level of a residence or building A second floor detector for example may not sense a first floor or basemant fire Moreover smoke detectors have sensing imitations No smoke detector can sense every kind of fire eve time In general detectors may not always warn about fires c...

Страница 23: ...emergency as intended occupants may have insufficient time to protect themselves from the emergency situation In the caae of a monitored Ialarm system euthorifies may not respond appropriately Ttis equipment like other electrical devices ie subject to component failure Even though this equipment is designed to last as long as 10 years the electronic components could fail at any time The most commo...

Страница 24: ...O ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY oTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLERS OWN NEGLIGENCE OR FAULT Some atatea do not allow hmitation on how long an imphed warranty Iasta or the exclusion or limitation of incidental or consequential damagas so the above limitati...