FLS M9.10

DUAL-PARAMETER ANALOG 

MONITOR & TRANSMITTER

SAFETY INSTRUCTIONS

PACKING LIST

General Statements

• Do not install and service the product without following the Instruction 

Manual

• This item is designed to be connected to other instruments which can be 

hazardous if used improperly. Read and follow all associated instrument 

manuals before using with it

• Product installation and wiring connections should only be performed by 

qualified staff

• Do not modify product construction

Installation and Commissioning Statements

 

• Remove power to the instrument before wiring input and output connections

• Do not exceed maximum specifications using the instrument

• To clean the unit, use only chemical compatible products

Please verify that the product is complete and without any damage. 

The following items must be included:

• M9.10 Dual Analog Input Monitor and Transmitter

• Instruction Manual for M9.10 Dual Analog Input Monitor and Transmitter

Содержание FLS M9.10

Страница 1: ... installation and wiring connections should only be performed by qualified staff Do not modify product construction Installation and Commissioning Statements Remove power to the instrument before wiring input and output connections Do not exceed maximum specifications using the instrument To clean the unit use only chemical compatible products Please verify that the product is complete and without...

Страница 2: ...e through a new in line calibration Two independent 4 20mA outputs are available to remote measures to external devices A proper combination of digital outputs 2 x SSR and 2 x relays allows customized setups for any process to be controlled TECHNICAL DATA General Associated sensors FLS hall effect flow sensors with frequency output FLS F6 60 flow magmeters family and every devices which generate a...

Страница 3: ...larm Off Optically isolated 50 mA MAX sink 24 VDC MAX pull up voltage Max pulse min 300 Hysteresis User selectable 2 x Relay output User selectable as MIN alarm MAX alarm ON OFF mode Timed mode Proportional mode Frequency mode Pulse Out only for frequency input Window IN Alarm Window OUT Alarm Off Mechanical SPDT contact Expected mechanical life min operations 107 Expected electrical life min oper...

Страница 4: ...anel or wall installation The panel version is installed using the panel mounting kit M9 SN1 while the wall mounting version is got fixing the panel mounting version on the wall mounting kit M9 KWX The mounting kits can be ordered directly connected to the monitor or separately and then simply installed on it PANEL MOUNTING WALL MOUNTING ...

Страница 5: ...ils M9 SN1 Wall installation Use the panel mounting kit M9 SN1 to fix the M9 10 on the dedicated frontal cutout of the wall mounting kit M9 KWX Tighten front screws of box and waterproof connectors of cables internally mount caps on screw sites to get a IP65 watertight installation ...

Страница 6: ...he upper part of the terminals for an easy cabling Insert wire tip or ferrule completely into the terminal and fix with the screw until finger tight Do not route the sensor DC power or 4 20mA cables in conduit containing AC power wiring Electrical noise may interfere with sensor signal Routing the sensor cable in grounded metal conduit can help prevent electrical noise and mechanical damage Wall I...

Страница 7: ...7 POWER WIRING DIAGRAM Power Supply 12 24 VDC 12 24 VDC VDC VDC 2 1 LOOP WIRING DIAGRAM ...

Страница 8: ...ly Connection to a PLC Instrument digital input for Voltage Free Contacts REED N O COM 3 4 Power Supply 12 24 VDC 12 24 VDC PLC Instrument Digital INPUT Digital INPUT Imax 50mA lmax 50mA lmax 50mA PLC DIGITAL INPUT N DIGITAL INPUT 2 DIGITAL INPUT 1 REF PLC N O Imax 50 mA Imax COM 3 4 lmax 50mA lmax 50mA USB PORT A USB port type B is available on the M9 10 PCB The USB connection allows the updating...

Страница 9: ...ON according to Relay setting If Imax 50 mA use external Relay Connection to an User NO 10 11 12 RELAY 2 NC COM Alarm AC or DC Power NO 10 11 12 RELAY 2 NC COM Alarm AC or DC Power N O 3 4 COM AC or DC Power User Imax 50mA N O 3 4 COM AC or DC Power User Imax 50mA lmax 50mA N O 3 4 COM AC or DC Power User Imax 50mA N O 3 4 COM AC or DC Power User Imax 50 lmax 50mA N O N O N C COM 4 3 COM External ...

Страница 10: ... IN2 IN 2 OUT mA 2 IN 1 OUT mA 1 Output Settings Settings Calibration Outputs Options View data Adjust input mA For negative values firstly set the corresponding positive value and then move the position indicator beyond the last position on the right using to get the minus sign not available for flow measurement for more info about Outputs Use the same Engineering Unit on both INPUTS Delta visual...

Страница 11: ...to scroll right to return to Menu without saving to save new settings INPUT 20 mA mA INPUT UNIT INPUT 4 mA 1 SSR 2 SSR 3 RELAY 4 RELAY 4 20 mA 1 4 20 mA 2 TEST OUTPUT INPUT 1 INPUT 2 INPUT 1 INPUT 2 INPUT 1 INPUT 2 LANGUAGE DECIMAL POINT INPUT 1 FILTER INPUT 1 DECIMAL POINT INPUT 2 FILTER INPUT 2 PASSWORD BACKLIGHT OUTPUT ACTIVATION DELTA IN CONTRAST UPGRADE FIRMWARE DEFAULT DATA ...

Страница 12: ...IT K FACTOR VALUE b IN 2 INFINITE TOTALIZER RESETTABLE TOTALIZER IN 2 OUT mA 2 IN 1 OUT mA 1 Output Settings INPUT 4 mA a FLOW UNIT INPUT 20 mA a VOLUME UNIT Settings Calibration Outputs Options View data Adjust input mA Resettable totalizers can be reset using on view level only with frequency input for more info about Outputs Delta visualization can be activated in Option Menù Use the same Engin...

Страница 13: ...TEMENT a 2 POINT CALIBRATION a CORRECTION FACTOR AUTO CALIBRATION 1 SSR a 2 SSR 3 RELAY a 4 RELAY 4 20 mA 1 a 4 20 mA 2 TEST OUTPUT LANGUAGE DECIMAL POINT INPUT 1 FILTER INPUT 1 DECIMAL POINT INPUT 2 FILTER INPUT 2 PASSWORD BACKLIGHT OUTPUT ACTIVATION UPGRADE FIRMWARE DELTA FLOW DEFAULT DATA CONTRAST RESET STATISTICS SIGNAL PROBE OUTPUT STATISTICS ADJUST INPUT 4 mA ADJUST INPUT 20 mA INPUT 1 INPUT...

Страница 14: ...u set the operating mode for each enabled output Digital outputs can be set in the following way Monitor without digital output activated In case a digital output is enabled a icon will appear In case a digital output is set icon reports the operating mode In case set digital output is activated the icon will turn to black ON OFF MODE icon reports O F LOW LEVEL ON OFF MODE icon reports O F HIGH LE...

Страница 15: ...oint I Prop Band Relay Prop Cond Set Point I His Set Point I Cond Relay Timed Endpoint 100 pulses from 0 to max pulses min Starting point 0 pulses 5 10 Set Point I His Set Point I Prop Band Relay Prop Cond Set Point I His Cond Set Point I Relay Timed MIN MODE icon reports MIN MAX MODE icon reports MAX Flow Time Hysteresis Output relaxed Output energized Setpoint Flow Time Hysteresis Output relaxed...

Страница 16: ...point Output relaxed Output energized Time Flow Hysteresis Setpoint Setpoint Hysteresis Output relaxed Output energized Time Flow Hysteresis Setpoint Setpoint Hysteresis Output relaxed Output energized Time Flow Hysteresis Setpoint Setpoint Hysteresis Output relaxed Output energized Time Flow Hysteresis Setpoint Setpoint Hysteresis Flow Time Hysteresis Output relaxed Output energized Setpoint Outp...

Страница 17: ...ftware NOTE At the end of the procedure restart the instruments in order to refresh M9 10 software It takes 90 seconds to refresh the SW Please do not interrupt the restarting process TO UPDATE NEW UNITS Download the interface software FLS Calibration System and the updated software on www flsnet it Launch the software FLS Calibration System on the laptop Push together ENTER and ESC powering the m...

Страница 18: ...alog monitor transmitter 110 230 VAC 3 4 wire 2 4 20mA 2 4 20mA 2 S S R 2 mech relay ACCESSORIES SPARE PARTS Part No Name Description M9 KW1 Wall mounting kit 144x144mm plastic box for wall installation of all panel mount monitors M9 KW2 Wall mounting kit with power supply 144x144mm plastic box and 110 230VAC to 24 VDC power supply for wall installation of all panel mount monitors M9 KUSB USB cabl...

Страница 19: ...19 NOTE ...

Страница 20: ...FIP Formatura Iniezione Polimeri S p A Loc Pian di Parata 16015 Casella Genova Italy Tel 39 010 96211 Fax 39 010 9621209 www flsnet it I2374 IMM910E REV 01 12 2016 ...

Отзывы: