background image

 

Version 2.0  

 

 

 

 

 

Page 

14

 

 

4.5.2

 

Time Alarm Settings Mode 

To enter the Alarm Mode, press and hold the 

ALARM

 key for two seconds (

ALARM

 + 2 

seconds). To advance each command, press (do not hold) the 

SET/CH

 key. 

 
 

Command 

Function 

Description 

Settings 

ALARM + 

2 seconds 

Alarm 
Hour 

Set the Alarm Hour Time 

Press 

TEMP/+

 or 

BARO/- 

to 

increase or decrease the alarm hour. 

SET/CH 

Alarm 
Minute 

Set the Alarm Hour Minute 

Press 

TEMP/+ 

or 

BARO/-

 to 

increase or decrease the alarm 
minute. 

SET/CH 

ALARM 
ON/OFF 

Turn  the  Time  Alarm  On  or 
Off.   

Press 

TEMP/+ 

to toggle between 

Time Alarm ON and Time Alarm Off 

SET/CH 

LOW 
Alarm 

Turn  the  LOW  Temperature 
Alarm On or Off 

Press 

TEMP/+ 

to toggle between 

Time Alarm ON and Time Alarm Off 

SET/CH 

 

Exit Set Mode 

 

Figure 10 

4.5.3

 

Cancelling the Alarm 

If the time alarm sounds, press the any key to silence the alarm. Press the 

LIGHT/SNOOZE 

key 

to enter snooze mode. 
 
The  low  temperature  alert  will  reset  automatically  once  the  value  has  fallen  into  the  low 
temperature alert range. 

4.5.4

 

Low Temperature Alarm 

The low temperature alarm sounds when the outdoor is between -3 °C and +2 °C (26.6 °F and 

35.6 °F). The LO temperature icon 

  will appear and flash on the console. If the BEEP is 

switched on, an audible alert will also activated when the low temperature alert occurs. 
 
If  you  own  more  than  one  sensor,  the  low  temperature  alarm  will  activate  for  any  one  of  the 
sensors. 

 

Figure 11 

Содержание WH32M

Страница 1: ...0 4 1 Set Mode 10 4 1 1 Time Zones 12 4 2 Barometric Pressure 12 4 2 1 Barometric Pressure History 12 4 2 2 Relative Pressure Calibration 13 4 2 3 Relative vs Absolute Pressure 13 4 3 Dew Point 13 4 4...

Страница 2: ...eshooting 1 1 What s New with the WH2812 The WH2812 only supported one remote wireless sensor The WH2812 supports up to three wireless remote sensors 1 2 Features The WH2812 features Wireless outdoor...

Страница 3: ...f a display console receiver thermos hygrometer sensor and AC adapter Note The power up sequence must be performed in the order shown in this section remote transmitter first display console second to...

Страница 4: ...1 Power Adapter Figure 1 3 2 Recommend Tools Hammer and nail for hanging remote thermo hygrometer transmitter 3 3 Thermo Hygrometer Sensor WH32M Set Up Remove the battery door on the back of the sens...

Страница 5: ...e and humidity and channel number on the display as shown in Figure 3 1 Temperature 2 Temperature Units of Measure 3 Channel Number 4 Humidity Figure 3 5 Close the battery door Note We recommend lithi...

Страница 6: ...indoor humidity 5 Date 18 Min indoor temperature 6 Moon phase 19 Max indoor temperature 7 Pressure rate of change 20 Indoor temperature 8 Barometric pressure 21 Min outdoor temperature 9 Barometric pr...

Страница 7: ...lay Insert three AAA alkaline or lithium avoid rechargeable batteries in the back of the display console Looking at the back of the unit left to right the polarity is for the top battery for the middl...

Страница 8: ...sful normally during the day due to solar interference the sensor search will be cancelled the outdoor temperature and humidity will update as normal and the RCC search will automatically resume every...

Страница 9: ...Wireless communication is susceptible to interference distance walls and metal barriers We recommend the following best practices for trouble free wireless communication 1 Electro Magnetic Interferenc...

Страница 10: ...Mode Alarm Mode Calibration Mode and Min Max Mode Any program mode can be exited at any time by either pressing the SNOOZE LIGHT key on the top of the display console or waiting for the 30 second time...

Страница 11: ...IN Minute of Day Press TEMP to increase BARO to decrease SET CH M D Month Day Format Press TEMP or BARO to toggle between M D month day format and D M day month format SET CH Y Year Press TEMP to incr...

Страница 12: ...ET Western European London England 1 CET Central European Paris France 2 EET Eastern European Athens Greece 3 BT Baghdad Moscow Russia 4 Abu Dhabi UAE 5 Tashkent 6 Astana 7 Bangkok 8 CCT China Coast B...

Страница 13: ...measured pressure Thus your absolute pressure may read 28 62 inHg 969 mb at an altitude of 1000 feet 305 m but the relative pressure is 30 00 inHg 1016 mb The standard sea level pressure is 29 92 in H...

Страница 14: ...urn the LOW Temperature Alarm On or Off Press TEMP to toggle between Time Alarm ON and Time Alarm Off SET CH Exit Set Mode Figure 10 4 5 3 Cancelling the Alarm If the time alarm sounds press the any k...

Страница 15: ...e the channel 2 humidity Press TEMP or BARO to increase or decrease the outdoor humidity offset SET CH CH 3 TEMP Calibrate the channel 3 temperature Press TEMP or BARO to increase or decrease the outd...

Страница 16: ...method is to calculate relative pressure to an official source near you as described in Section 4 2 2 To exit the calibration mode at any time press the LIGHT SNOOZE button Note The calibration offset...

Страница 17: ...r is generally improving sunny to partly cloudy If the rate of change of pressure decreases the weather is generally degrading cloudy rainy or stormy If the rate of change is relatively steady it will...

Страница 18: ...rter Waning New Figure 15 4 8 5 Pressure Tendency Arrows The forecast trend arrow updates every 30 minutes The trend reflects changes in pressure 1 hPa over the past 3 hours Pressure is rising Pressur...

Страница 19: ...ET CH and TEMP button for 5 seconds to register the outdoor transmitter The sensor search icon will flash Please wait several minutes for the remote sensor reports in Do not touch any buttons until sy...

Страница 20: ...tions from one location to another meteorologists correct pressure to sea level conditions Because the air pressure decreases as you rise in altitude the sea level corrected pressure the pressure your...

Страница 21: ...n Base station 5V DC adaptor included 3 x AAA 1 5V Batteries not included Remote sensor 2 x AAA Batteries not included Battery life About 12 months for base station About 12 24 months for thermometer...

Страница 22: ...r and Outdoor Temperature do not agree Allow up to one hour for the sensors to stabilize due to signal filtering The indoor and outdoor temperature sensors should agree within 3 6 F the sensor accurac...

Страница 23: ...rate the equipment Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Statement according to FCC part 15 1...

Страница 24: ...Version 2 0 Page 24...

Отзывы: