Press          , and the first level of temperature will flash.

Set the desired temperature using the keys           or          .

Press           to confirm and to pass to next temperature level.

Set the desired temperature using the keys           or           .

Press           to confirm and to pass to next temperature level.

Set the desired temperature using the keys           or          .

Press           finally to return to the main screen.

NOTE

- Level 1 will be the lowest temperature of the 3 levels.

Levels 2 and 3 being progressively higher.

- With the SUMMER setting, the association between Level and temperature

is reversed (ie. Level 3 represents the lowest temperature).

T

T

TEMPERATURE SETTING

T

T

16

Содержание 1C.51

Страница 1: ...rzycisk w i wprowadzania komend Kompatybilne z tr jmodu owym systemem osprz tu elektroinstalacyjnego np typ 503 N L Schemat czeniowy 1C 81 Kolor Programowany tygodniowo Bia y RAL 9010 1C 81 9 003 0107...

Страница 2: ...azwy i zapisa odno ne programy na telefonie Po zbli eniu smartfonu do termostatu zaprogramowane warto ci s natychmiast przesy ane Aplikacja umo liwia zaprogramowanie tygodniowych temperatur zmian zapr...

Страница 3: ...Dynamiczne ikony Kompatybilne z tr jmodu owym systemem osprz tu elektroinstalacyjnego np typ 503 Schemat czeniowy 1C 61 Kolor Programowany dziennie Bia y RAL 9010 1C 61 9 003 0101 Metaliczny antracyt...

Страница 4: ...54 Czujnik 01C 61 s u y do mierzenia temperatury na zewn trz pomieszczenia w kt rym znajduje si termostat 1C 61 Czujnik 1C 61 mo e wy wietla temperatur zewn trzn i regulowa j w stosunku do czujnika w...

Страница 5: ...BTicino seria Light tech BTicino seria Living BTicino seria Livinglight BTicino seria Matix Gewiss seria Chorus Vimar seria Eikon Vimar seria Eikon Evo Vimar seria Idea Vimar seria Plana Vimar seria A...

Страница 6: ......

Страница 7: ...1C 51 DIGITAL TOUCH CHRONOTHERMOSTAT...

Страница 8: ...page 8 SYMBOLS page 9 TIME DATE SETTING page 10 MANUAL MODE page 12 DISPLAY LOCK page 13 FULL THERMOSTAT LOCK MODE WITH PIN page 14 TEMPERATURE SETTING page 16 PROGRAMMING page 17 TIMED MANUAL FUNCTI...

Страница 9: ...Temperature differential T 0 1 0 9 C Internal sensor accuracy 0 5 C Minimum programming interval 1 hour Degree protection IP20 Output relay 1 CO volt free contact Contact rating 5A 250VAC Mounting re...

Страница 10: ...ad is within the ratings marked on the thermostat POSITIONING Install the programmable thermostat away from sources of heat heaters direct sunlight kitchens and from doors windows at a height of about...

Страница 11: ...Living Light Light Tech Livinglight Axolute Bticino Matix Gewiss Chorus Vimar Arke Vimar Eikon Eikon Evo Plana Vimar Idea Bticino Livinglight Air Frame A Frame B Extender VI Extender BM remove the si...

Страница 12: ...WIRING DIAGRAM MANUAL override contact NO U COM NC 5...

Страница 13: ...at remains unused for long periods it is advisable to remove the batteries The thermostat provides 3 different reports of battery condition With the battery ON STEADY operation of the thermostat will...

Страница 14: ...ed numerically from 1 to 7 C Temperature display in Celsius D Active icons eg fan Cooling ON flame Heating ON E Time temperature profile The column corresponding to the current time will flash F Allow...

Страница 15: ...sed for 3 seconds activates or deactivates the LOCK mode Allows the TIME and DATE to be set Pressed for 3 seconds it is possible to access at the advanced menu Changes the data displayed increase Chan...

Страница 16: ...ode Cooling ON in SUMMER mode Frost protection ON Displays Low battery Unit of measurement Temperature differential Indicates the LOCK mode active 24 hour time temperature profile Displays the days of...

Страница 17: ...eys Confirm with and advance to the next parameter To step back or exit from the menu press EXAMPLE Press The HOUR flashes Enter the correct time through keys Pressing confirms the hour setting and it...

Страница 18: ...ES Removing the batteries the thermostat has a power reserve of 40 seconds after which settings hours minutes day month year will be lost The day of the week number is automatically set based on the c...

Страница 19: ...nge it use to increase or to decrease the value To confirm and exit press NOTE If you do not touch the display for 3 seconds the screen will revert to show the current measured temperature To set a ne...

Страница 20: ...cessary to press for 3 seconds The symbol flashes adjacent to the displayed temperature indicating that the lock is activated To deactivate press for 3 seconds display locked NOTE To use the DISPLAY L...

Страница 21: ...he screen shows which then allows the personal PIN code to be entered Press keys or to attain the PIN number and confirm with It is now possible to exit from the Advanced settings pressing key several...

Страница 22: ...with 3 beeps confirm that the lock has been disabled ATTENTION After 3 failed attempts it will not be able to enter any PIN for 20 seconds The ERR message will remain fixed on the display NOTE Also on...

Страница 23: ...ess to confirm and to pass to next temperature level Set the desired temperature using the keys or Press finally to return to the main screen NOTE Level 1 will be the lowest temperature of the 3 level...

Страница 24: ...middle of the profile to pass to programming the time temperature profile PROGRAMMING THE 24 HOUR TIME TEMPERATURE PROFILE Starting with the zero hour segment of the profile blinking With or select t...

Страница 25: ...or exit from the menu with the key When the programming is finished press the key to exit from the advanced menu Everything confirmed with the key will be saved The display will then show the main scr...

Страница 26: ...s will be highlighted by a black background Press the time temperature profile With the first hour of the profile flashing press key for 3 seconds 3 beeps confirm that the copy of the program is regis...

Страница 27: ...set the temperature in the same way by the keys or Confirm with Following confirmation a digital countdown plus a circular motion graphic will be displayed Press to view the set temperature To exit f...

Страница 28: ...the other hours of the day while using the key it is possible to go back to the previous hour value After the change s there is no need to press any other keys After a few moments the function starts...

Страница 29: ...INTER and is OFF It serves to protect the system against very low temperatures Upon reaching the set threshold the function will be activated and the display will show the icons At any time press to t...

Страница 30: ...ostat into the MANUAL mode In this state the temperature can be adjusted only by using the or keys NOTE The temperature initially displayed will be the temperature previously set in the Manual mode RE...

Страница 31: ...N 7 RESET To enter to advanced settings start from the main screen press to turn off the thermostat Press the key for 3 second 1 SUMMER WINTER mode The display shows one of the following screens Choos...

Страница 32: ...xit press the key for 3 seconds or press repeatedly until the message OFF appears on the screen If something has been changed 3 beeps will confirm the successful change 3 THERMAL DIFFERENTIAL After co...

Страница 33: ...tting a value between 1 and 99 hours the thermostat will close the output contact for 30 seconds every time the set time value has elapsed Example By setting with keys or the value 48 48 hours 2 days...

Страница 34: ...tically change to daylight savings time With the keys or it is possible to change this value to ZERO so that the daylight saving changeover does not happen automatically Press to confirm and proceed t...

Страница 35: ...or keys To enable the lock mode for the entire thermostat set the PIN to a number between 001 and 999 When in service if it is required to lock the display just press the key for 3 seconds see pag 13...

Страница 36: ...or set Confirming with the thermostat will turn off completely and then turn back on showing first the version of the software and then the main screen The product will be reset to its factory setting...

Страница 37: ...IB1C51EN 11 16 FINDER S p A 10040 ALMESE TO ITALY...

Отзывы: