EN
17
3.5 Technical data
3.5.1 Technical data table
PVS-10-TL
PVS-12.5-TL
PVS-15-TL
Input side
Absolute maximum DC input voltage (Vmax,abs)
1100 V
Start-up DC input voltage (Vstart)
250...500V (default 360V)
Operating DC input voltage range (Vdcmin...Vdcmax)
200…1000 V
Rated DC input voltage (Vdcr)
620V
Rated DC input power (Pdcr)
10200 W
12760 W
15300 W
Number of independent MPPT
2
Recommended maximum PV array power (PPV, max)
14500 Wp
18125 Wp
21750 Wp
Maximum DC input power for each MPPT (PMPPT,max)
7800W
8300W
10000W
MPPT input DC voltage range (VMPPTmin ... VMPPTmax) at Pacr
460-850V
Maximum DC input current (Idcmax) for each MPPT
17A
18A
22A
Maximum input short circuit current for each MPPT
30 A
Maximum return current (AC side vs DC side)
Negligible in normal operating conditions
(6)
Number of DC inputs pairs for each MPPT
2
DC connection type
PV quick fit connector
(3)
Type of photovoltaic panels that can be connected at input
according to IEC 61730
Class A
Input protection
Reverse polarity protection
Yes, from current limited source
Input over voltage protection for each MPPT
SPD Type 2 / Type 1+2 (optional)
Photovoltaic array isolation control
Yes, according to IEC 62109-2 or according to local regulation
Residual current monitoring Unit (leakage current protection)
Yes, according to IEC 62109-2
DC switch rating for each MPPT (version with DC switch)
Rating DC-PV1. 50A@600Vdc, 40A@800Vdc, 30A@1000Vdc
String Fuse
Fuseless
Input current monitoring
String level
Output side
AC Grid connection type
Three phase (3W+PE or 4W+PE)
Earthing system
TN-S, TN-C, TN-CS, TT
Rated AC power (Pacr @cosf=1 )
10000 W
12500 W
15000 W
Maximum AC output power (Pacmax @cosf=1)
10000 W
12500 W
15000 W
Maximum apparent power (Smax)
10000 VA
12500 VA
15000 VA
Rated apparent power (Sr)
10000 VA
12500 VA
15000 VA
Maximum reactive power (Qmax)
6000 VAR
7500 VAR
9000 VAR
Nominal power factor and adjustable range
> 0.995; 0,8…1 inductive / capacitive
Rated AC grid voltage (Vac,r)
380V, 400V
(1)
Rated Output Current (Iac nom)
14.5 A
18.1 A
21.7 A
Maximum AC output current (Iac,max)
16 A
20 A
23 A
Contributory fault current
Iac,max x 1,15
Rated output frequency (fr)
50 Hz / 60 Hz
Output frequency range (fmin...fmax)
47...53 Hz / 57…63 Hz
(2)
Total harmonic distortion of current
<3%
Max DC Current Injection (% of Iac,max)
< 0.5%*Iac,max
Maximum AC cable
16 mm
2
copper
AC connection type
AC quick fit connector
Output protection
Anti-islanding Protection
According to local standard
Maximum external AC overcurrent protection
25 A
32 A
32 A
Output overvoltage protection
SPD Type 2
Operating performance
Maximum Efficiency (ηmax)
98.4%
98.5%
98.5%
Weighted Efficiency (EURO)
98.1%
98.2%
98.2%
Содержание PVS-10-TL
Страница 1: ...Solar Inverter PVS 10 12 5 15 TL Product Manual ...
Страница 15: ...EN 15 3 4 1 Inverter external view 02 07 05 01 03 04 26 09 23 08 20 21 ...
Страница 16: ...EN 16 08 05 19 19 09 16 18 18 25 15 14 17 13 12 10 11 ...
Страница 79: ...EN 79 ...