EMPTYING DRUM COLLECTION
CLEANING SOLUTION TANK EMPTYING
At the end of the work and before any type of maintenance, do the following:
Bring the appliance to the place used for emptying the collection shaft.
IMPORTANT
: The place used for this operation must be in compliance with the current
environmental regulations.
PRUDENCE
: These operations must be carried out using gloves to protect your hands.
1.
Switch off the appliance, set the general switches (1) to the “0” position (Fig. 1).
2.
Remove the plug (2) from the power supply cable (3) from the mains socket (4) (Fig. 2).
WARNING:
To avoid damaging the power cable, disconnect the plug from the mains socket by
pulling the plug directly instead of the cable.
3.
Remove the suction head (5) by means of the handle placed above it, before removing the head
loosen the retaining clips (6) Located on the side of the collection shaft (7) (Fig. 3) and lay it on the
ground.
IMPORTANT:
Before removing the suction cover, remember to unscrew the plug (8) in the
solution tank (Fig. 4).
Before a long period of inactivity or before any type of maintenance, do the following:
1.
Bring the appliance to the place used for emptying the collection shaft.
IMPORTANT
: The place used for this operation must conform to the regulations in force of
environmental respect.
PRUDENCE
: These operations must be carried out using gloves to protect your hands.
2.
Switch off the appliance, set the general switches (1) to the “0” position (Fig. 1).
3.
Remove the plug (2) from the power supply cable (3) from the mains socket (4) (Fig. 2).
WARNING
:
To prevent damage to the power cord, disconnect the mains plug from the mains
socket by pulling the plug directly instead of the cable..
4.
Remove the CAP (5) of the Detergent solution tank (6) (Fig. 3).
5.
Remove the detergent solution tank (6) from the Support (Fig. 4).
6.
Empty the detergent solution tank.
7.
Refit the whole.
4.
Remove the drain pipe (9) from the catch (Fig. 5) from the latch.
5.
Unscrew the CAP (10) and place the hose on the drain surface and gradually release the tube (Fig.
6).
6.
Empty the collection drum.
If there are also solid bodies inside the collection shaft, perform the following:
MAINTENANCE
Properly cleaning the vacuum unit makes sure the appliance works efficiently and effectively when
operating, to carry out maintenance do as follows:
1.
Take all necessary steps to ensure that the device is in a safe condition (see “
MACHINE SAFETY
”).
2.
Remove the vacuum head (1) using the handle, before removing the head loosen the locking hooks
(2) on the side of the collection tank (3) (
Fig.1
). Rest the vacuum head gently on the floor.
IMPORTANT:
Before removing the suction cover, remember to unscrew the plug (4) in the
solution tank (Fig. 2).
3.
If present, remove the sponge filter (5) (Fig. 3) and clean it, wipe the mechanical float with a damp
cloth (6) (Fig. 4). When dry refit the sponge filter.
IMPORTANT:
If the surface of the filter is extremely dirty, brush the filter with a normal soft brush
to clean it thoroughly, and if necessary wash it in water.
SURFACE CLEANING METHODS
To perform a good job of washing the surfaces we suggest:
1.
Before using the appliance, be sure on a hidden spot of the object to be cleaned of the colour stability
and water resistance.
2.
Take the surface to be cleaned when overlapping, during this operation pull back the nozzle do not
push it forward.
3.
For normal dirt, spray and aspirate the detergent solution in one step.
IMPORTANT:
A second suction without spraying reduces the drying time.
4.
For intense or stains, apply the detergent solution with the suction motor deactivated and operate
for 10-15 minutes.
IMPORTANT:
To further improve the cleaning result, rinse the surface with clean and
warm water if necessary.
5.
For sensitive tissues, dose the detergent in minimal quantities and spray the surface at a distance of
about 200mm. then simply aspirate.
6.
Treat the very dirty parts beforehand and allow the detergent solution to take action for 5-10 minutes.
7.
Always wash from light to shade
8.
Always operate from the clean surface to the dirty surface.
9.
The more sensitive the coating is (e.g. Oriental rugs, Berbers, padded fabrics), the less detergent
concentration must be used.
10.
Carpets with a jute fund in case of excessively humid operations may contract and Discolor.
11.
Brush the long-haired carpets after cleaning when they are still wet in the direction of the hair (e.g.
with a hair brush or a rag).
12.
It runs through the treated surface or place furniture only after drying to prevent fingerprints or stains
from being formed.
13.
During the cleaning of carpets previously treated with shampoo, foam is created in the collection
frame, in this case pour an anti-foaming product inside the keg.
Use the handle (11), located at the front of the keg, to turn the collection shaft upside down (Fig. 7).
PRUDENCE:
During the tipping phase of the collection shaft, hold the appliance firmly using the
control handlebar (11).
CAUTION:
Before turning the appliance upside down, remove the detergent solution tank from
the support.
•
Remove dirt from inside the keg, rinse and clean with a damp cloth.
IMPORTANT:
If present, remove the fabric filter from the inside
of the collection shaft before emptying the appliance.
•
Refit the whole.
ATTENTION:
Check the condition of the foam filter if the filter surface area is particularly clogged
or if it is damaged replace it
4.
If present, remove the fabric filter (7) (Fig. 5) and clean it. When dry refit the cloth filter.
IMPORTANT:
If the filter surface is extremely dirty, it is advisable to brush the filter to thoroughly
clean it with a normal soft brush, if necessary wash it in water.
IMPORTANT:
If you use cartridge filters or dust-collecting bags (cotton version) instead of the
cloth filter, clean them with a jet of air and check their storage status if necessary to replace
them.
ATTENTION:
Check the wear condition of the fabric filter if the filtering surface is particularly
obstructed or damaged, proceed with the replacement.
5.
Wipe the inside of the collection drum with a damp cloth.
6.
Refit the suction head (1) above the collection frame (3), remember to fix it using the retaining hooks
(2).
7.
Disconnect the male connector (8) of the detergent Solution Distribution Tube (9) from the female
Connector (10) in the suction head (Fig. 6).
10
11
9
6
6
5
1
1
6
4
4
2
2
3
3
1
1
4
2
2
8
4
5
6
4
2
3
3
5
At the end of the work, and before carrying out any type of maintenance, perform the following operations:
1.
Take the appliance to the place where it is maintained and carry out all the procedures listed in the
chapter “
MAINTENANCE
”.
2. Take the appliance to the designated machine storage place.
3.
Take all necessary steps to ensure that the device is in a safe condition (see "
MACHINE SAFETY
”).
ATTENTION:
Park the appliance in an enclosed place, on a flat surface; near the appliance there
must be no objects that could either damage it, or be damaged through contact with it.
AT THE END OF THE WORK
5
6
7
3
1
2
3
1
Содержание FE A65.2 DP
Страница 2: ...ITALIANO 3 FRAN AIS 15 ENGLISH 25...
Страница 37: ...37...
Страница 38: ...38...
Страница 39: ...39...