SANITIZING SOLUTION
After filling the solution tank with clean water, add the sanitizing chemical product to the tank in the concentration and manner indicated on the
sanitizing product manufacturer's label.
ATTENTION:
It is recommended to wear the appropriate PPE (Personal Protective Equipment), suitable for the work to be carried out.
The solution tank can be filled with water in two different ways:
•
Removing the cap/measuring device (9) and filling the solution tank by means of a rubber hose or a bucket (
Fig.11
).
•
Using the filler hose (10) (
Fig.12
), which supports the water hose on its own. In this case, be sure to remove the cap/measuring device (9) in
order to allow the air to vent properly.
4.
Fill with clean water, at a temperature no higher than 50°C (122°F) and no lower than 10°C (50°F). The amount inside the tank can be seen
by means of the level tube (11) on the left-hand side of the machine (
Fig.13
).
INSERTING WATER SYSTEM FILTER
Before using the machine for the first time the water system filter needs to be reset, for shipping reasons the filter cartridge and the cap have
been removed. To insert the filter cartridge in the water system filter body proceed as follows:
1. Take the machine to the maintenance area.
2.
Carry out the steps necessary to secure the machine, see paragraph “MACHINE SAFETY” on page 17.
ATTENTION:
It is recommended to wear the appropriate PPE (Personal Protective Equipment), suitable for the work to be carried out.
3.
Close the tap's output flow, and shift the knob (12) on the left hand side of the steering column (
Fig.14
) downward.
4.
Move to the front of the machine, insert the filter cartridge (13) in the housing on the cap (8) (
Fig.15
).
N.B.:
The O-ring gasket in the filter cartridge should be inserted into its seat in the cap.
5.
Screw the cap (8) onto the body of the sanitizing solution filter (14) (
Fig.16
).
PREPARING TO WORK
Before beginning to work, it is necessary to:
1.
Check that the quantity of sanitizing solution in the solution tank is correct for the type of work to be carried out; if not, refill the solution tank.
2.
Check that the main switch is set to “0", turn the key (1) a quarter turn anti-clockwise (
Fig.1
) . With the machine off, remove the key from the
instrument panel.
3.
Press the recovery tank release lever (2) and turn the recovery tank into the maintenance position (
Fig. 2
).
WARNING:
It is recommended that all installation and maintenance operations be carried out by expert personnel, trained at the
specialised assistance centre.
4. Connect the battery connector to the machine's general system connector.
5.
Rotate the recovery tank into the work position. Make sure that the recovery tank retainer system is correctly engaged (
Fig. 3
).
6.
Move to the right rear part of the machine and check that the electro-brake in the traction gear motor is engaged, turn the lever (3) clockwise
(
Fig. 4
).
7.
Move to the front of the machine and check that the water system filter cap (4) is closed, otherwise tighten it (
Fig.5
).
8.
Move to the front left part of the machine and check that the water tap is opened completely, turn the knob (5) upwards (
Fig.6
).
20
6
5
5
4
4
3
1
1
3
2
2
2