Hands-Free B103 Bottle Filling Station 

Maintenance Instructions

DRAWING 

PART NO.

DESCRIPTION

ORDER PART 

NO.

1

CARTRIDGE REGULATOR ASSEMBLY

45.0006

2

BATTERY BOX

6.1712

AA LITHIUM BATTERIES - 4 PACK

51.0592

3

CONTROL MODULE

6.1716

4

SOLENOID VALVE

6.1708

5

SENSOR (FOR B103 WITH BOTTLE 
COUNTER)

6.1714

RED LENSE

6.1717

6

SENSOR (FOR B103 WITHOUT BOTTLE 
COUNTER)

6.1713

7

BOTTLE COUNTER, 3-30VDC

6.1730

ASSEMBLY

SENSOR ASSEMBLY (FOR B103 WITH 
BOTTLE COUNTER) - PART NO. 2, 3, 4 & 5)

6.1709

ASSEMBLY

SENSOR ASSEMBLY (FOR B103 WITHOUT 
BOTTLE COUNTER) - PART NO. 2, 4 & 6

6.1710

Sensor Activated B103

Maintenance Instructions

To remove the cover plate,  unscrew the Jackman 
screws from both sides and slide the cover plate out.

Cartridge Regulator Replacement and Flow 
Adjustment:

Turn off water to the fixture and depress button on 
cartridge regulator to drain water left in the line.

Using the spanner wrench or needle nose pliers, 
unscrew the brass regulator retaining ring.

Gently wiggle cartridge back and forth to remove it 
from the brass valve assembly body.

Check to ensure that the old neoprene seal was also 
removed. Install new neoprene seal on the new 
cartridge regulator and install new assembly into the 
valve body, ensuring inlet and outlet holes on the 
cartridge are lined up and the cartridge is seated 
properly in the valve body.

Reinstall the regulator retaining ring and tighten using 
the spanner wrench or needle nose pliers.

Turn on water to fixture and test for flow and leaks by 
pushing plunger with flat screwdriver. 

Adjust the flow by turning the white screw head on the 
cartridge regulator. Turn it clockwise to decrease flow 
and counterclockwise to increase flow.

Sensor Adjustment:

To adjust the distance of the sensor intensity, turn 
yellow phillips head screw on control module circuit 
board clockwise to lengthen distance and counter 
clockwise to shorten it.

Bottle Counter Reset:

To reset the bottle counter, press and hold the black 
reset button (see diagram above for location) for a few 
seconds while passing hand across the sensor.

Filtrine Mfg. Co.  ∙  15 Kit St. Keene, NH 03431 USA
800-930-3367  ∙  603-352-5500  ∙  FAX (603) 352-0330