![Filtration Group R5-3 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/filtration-group/r5-3/r5-3_translation-of-the-original-instructions_2288869011.webp)
Page 11
Translation of the original instructions with installation instructions R5- Filtration Group GmbH,, 24.05.2019, Mat. No. 70580785, Revision 04
3
Undo the insert cover and base
Remove the feather key for the nozzle and lift the
nozzle out
Remove the insert.
Fig. 8:
Separating the filter insert
Fig. 9:
Removing the wire cloth
Removing the wire cloth ( if fitted )
Pull off the supporting cylinder (3).
Pull off the wire cloth cylinder (2).
The wire cloth cylinder can now be serviced or
replaced
( refer to section 14.5 / 14.6 )
Assembly
Push a new or cleaned wire cloth cylinder (2) over
the body (1).
Pull the support cylinder (3) over the wire cloth
cylinder making sure the wire cloth does not get
damaged.
Installing the filter insert
Fit the filter insert together with the insert cover and
base
Push the filter insert into the housing and fix the
cover
14.5 Cleaning the automatic filter
Remove the filter insert (refer to section 14.4).
14.5.1 Cleaning the filter insert
WARNING!
Danger of aerosol formation!
All work must be carried out in a room with a
suitable extraction system!
Wear protective clothing and equipment
appropriate to the hazard potential of the medium
(e.g. goggles, respirator, protective clothing, etc.).
Remove any coarse impurities by mechanical
means.
Wash out the wire cloth in a suitable cleaning
solution.
Clean the wir cloth from the outside towards the
inside.
Carefully blow out the filter insert with a steam jet or
compressed air.
Clean (or if necessary renew) and oil the seals.
14.5.2 Cleaning the filter housing
Wear protective clothing and equipment
appropriate to the hazard potential of the medium
(e.g. goggles, respirator, protective clothing, etc.).
Remove any coarse impurities by mechanical
means.
Wash out the filter housing in a suitable cleaning
solution.