17 Troubleshooting table
Fault
Cause
Remedy
Water not separated
Volume flow rate too high
Reduce the volume flow rate
Fluid not suitable
Don't use detergent liquids (water
binding additives)
Viscosity too high
Make sure the temperature is suitable
for the fluid
Warning signal from maintenance
indicator
Cold start
Reset the signal after reaching
operating temperature
Coalescer element dirty
Replace the coalescer element
Water level sensors show incorrect
values
Water level sensors set incorrectly
Set the water level sensors correctly
(see plan).
Please contact the manufacturer if the fault still persists after carrying out the corrective measures described above.
18 Spare parts
Part name / DIN designation
ID No.
Benennung/DIN Bezeichnung
Coalescer element
76361281
Coalescerelement
Seal kit
72348122
Dichtungssatz (inkl. Anzeigedichtungen und
Entlüftungsschraube)
Droplet separator
72356994
Tropfenabscheider
Water level sensor
72348133
Wasserstandsensor
Electrical top part
77536550
El. Oberteil
Use only FG original spare parts!