Page 5
Translation of the original instructions with installation instructions Pi 480, Filtration Group GmbH, 24.01.19, Mat. No. 70308062, Version 02
6.2 Main components of the filter
Fig. 2: Diagram of the main components
1 Maintenance indicator (optional)
2 Inlet
3 Filter head
4 Filter housing
5 Drain plug (optional)
6 Outlet
6.3 Operating principle of the filter
Fig. 3: Operating principle
1
Dirty fluid flows in through the inlet.
2
The fluid flows through the filter element to the clean side.
3
The filtered fluid exits the filter via the outlet.
4
Replace the filter element after the trial run or after flushing
the system. Then comply with the intervals specified by the
system manufacturer; the element should be replaced
every six months at the latest.
Wire cloth elements can be cleaned (refer to section 13.5).
Disposable elements (MIC, SMX, PS) must be exchanged
and disposed of correctly.
Optional:
If a maintenance indicator is used, a signal is output when
the maximum differential pressure is reached.
3
2
1
4
5
6
1
3
2