background image

Filtertechnik 

1 Central Park, Lenton Lane, Nottingham, NG7 2NR

 

 

 

Tel:  

+44 (0)115 9003 600

 

 

Email

[email protected]

 

Fax: 

+44 (0)115 986 8875

 

 

Web: 

www.filtertechnik.co.uk

 

Registered in England No: 03969985   VAT No: 760 821 731   

Certification No. UK002838

 

 

 

Page 10 of 15 

 

 

Spare Parts List 

 
 

 

 

 

 

 

 

Warranty Statement 

 
All products manufactured or distributed by Filtertechnik Ltd are subject to the following, and only 
the following, Limited Express Warranties, and no others: 

For a period of one (1) year from and after the date of delivery of a new Filtertechnik product, 
Filtertechnik warrants and guarantees only to the original purchaser/user that such a product shall 
be free from defects of materials and workmanship in the manufacturing process.  The warranty 
period for pumps and motors is specifically limited to ninety (90) days from the date of delivery.  A 
product claimed to be defective must be returned to the place of purchase.  Filtertechnik, at its sole 
option, shall replace the defective product with a comparable new product or repair the defective 
product.  This express warranty shall be inapplicable to any product damaged or impaired by external 
forces or used for any purpose other than that for which it was originally sold. 

THIS IS THE EXTENT OF WARRANTIES AVAILABLE ON THIS PRODUCT.  FILTERTECHNIK SHALL HAVE NO 
LIABILITY WHATSOEVER FOR CONSEQUENTIAL DAMAGES FOLLOWING THE USE OF ANY DEFECTIVE 
PRODUCT OR BY REASON OF THE FAILURE OF ANY PRODUCT.  FILTERTECHNIK SPECIFICALLY 
DISAVOWS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED INCLUDING, WITHOUT LIMITATION, ALL 
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE (EXCEPT FOR THOSE WHICH APPLY TO 
PRODUCT OR PART THEREOF THAT IS USED OR BOUGHT FOR USE PRIMARILY FOR PERSONAL, FAMILY 
OR HOUSEHOLD PURPOSES), WARRANTIES OF DESCRIPTION, WARRANTIES OF MERCHANTABILITY, 
TRADE USE OR WARRANTIES OF TRADE USAGE. 

 

 

Description 

Part Number 

1 µm Absolute 

9VZ1 

3 µm Absolute 

FTB-03 

5 µm Absolute 

FTB-05 

10 µm Absolute 

FTB-10 

25 µm Absolute 

FTB-25 

150 µm Recleanable 

9VM150 

Water Removal 

9VW 

Содержание SFC-3000-316-AIR

Страница 1: ...el 44 0 115 9003 600 Email sales filtertechnik co uk Fax 44 0 115 986 8875 Web www filtertechnik co uk Registered in England No 03969985 VAT No 760 821 731 Certification No UK002838 SFC 3000 316 AIR U...

Страница 2: ...ing Stopping 5 Filtration 6 Differential Pressure Gauge 6 Pump Information 7 Performance Curve 7 Hoses Lances 8 Suction Strainer 8 Troubleshooting 9 Spare Parts List 10 Warranty Statement 10 EC Declar...

Страница 3: ...eight 42 5 kg Frame 316 stainless steel Finish N A Voltage N A Frequency N A Current N A Power N A Pump type Air operated diaphragm pump Flow rate max 50 L min Viscosity range 5 to 100 cSt Duty Cycle...

Страница 4: ...of hydraulic systems Emptying waste fluid quickly Health Safety Environmental Considerations This equipment should only be used for its intended purpose by competent and authorised persons inappropria...

Страница 5: ...the ends of both the inlet and outlet standpipe as far apart as possible inside the reservoir in order to ensure proper recirculation and cleaning Cycle the hydraulic system thoroughly in order to fl...

Страница 6: ...d in England No 03969985 VAT No 760 821 731 Certification No UK002838 Page 4 of 15 Component Identification Key 1 1 Suction Lance With Strainer 6 1 4 Drain Valve 2 1 Discharge Lance 7 Inlet Port 1 BSP...

Страница 7: ...tered in England No 03969985 VAT No 760 821 731 Certification No UK002838 Page 5 of 15 Flow Direction Starting Stopping With the need valve fully closed connect the unit to a suitable air supply via t...

Страница 8: ...rely To change a filter element 1 Make sure the air supply is disconnected from the unit 2 Open the drain port and collect the oil fuel into a suitable waste container 3 Remove the v band clamp and fi...

Страница 9: ...T No 760 821 731 Certification No UK002838 Page 7 of 15 Pump Information Specification Detail Max capacity 78 l min Volume per stroke 130 ml Max discharge pressure 8 bar Max air pressure 8 bar Max suc...

Страница 10: ...a suction lance with strainer to protect the pump and a discharge lance Each lance is 1000mm long When not in use it is advisable to plug the hoses and cap off the lances to prevent ingress of dust o...

Страница 11: ...tion in hoses Suction leak Worn diaphragm Normal for H V fluids Replace element s Clean hoses Check tightness of fittings Replace gears Element indicator shows red Element dirty Oil extremely cold Oil...

Страница 12: ...e of purchase Filtertechnik at its sole option shall replace the defective product with a comparable new product or repair the defective product This express warranty shall be inapplicable to any prod...

Страница 13: ...NG7 2NR Tel 44 0 115 9003 600 Email sales filtertechnik co uk Fax 44 0 115 986 8875 Web www filtertechnik co uk Registered in England No 03969985 VAT No 760 821 731 Certification No UK002838 Page 11 o...

Страница 14: ...e understand the ISO 4406 contamination scale conversion between the various cleanliness standards and understanding how the ISO 4406 scale relates to the NAS contamination scale Number of Particles p...

Страница 15: ...or optical microscope count1 1 m 5 m 15 m 25 m 50 m 100 m Size ISO 11171 calibration or electron microscope2 4 m c 6 m c 14 m c 21 m c 38 m c 70 m c Size Code A B C D E F Class 000 195 76 14 3 1 0 Cl...

Страница 16: ...0 1 1 14 12 9 3 0 13 11 8 2 12 10 8 100 10 10 7 1 12 10 6 0 01 11 9 6 Cleanliness Standards Conversion Equivalent ISO 4406 Code approx NAS Code Size Range in Microns m 5 15 15 25 25 50 50 100 100 00...

Страница 17: ...N A Variable Piston 18 16 13 17 15 12 16 14 11 Valve Check Valve 20 18 15 20 18 15 19 17 14 Directional Solenoid 20 18 15 19 17 14 18 16 13 Standard Flow Control Valve 20 18 15 19 17 14 18 16 13 Cartr...