Chapter 4: Diagnostics and Troubleshooting
4-15
The rejector does not function
1.
Is the rejector activated? Verify the Rejector Status Function is
enabled.
2.
If you hear a clicking sound, but the rejector does not activate,
the air pressure is not turned on. Turn on air pressure to the
rejector.
3.
Check the cable between the rejector and the inspection units
for broken or frayed wires. If damaged, contact your Service
Department.
4.
The rejector Pulse Width function may need adjustment.
Contact IDC Customer Support for assistance.
All containers are rejected
1.
The fill level calibration is incorrect and all containers are regis-
tering as rejects. Contact your Service Department.
2.
If system uses multiple container types, is the correct container
type selected?
The rejector is operating erratically
1.
Is sufficient oil getting to the rejector? Check the oil level in the
oiler (on some models only).
2.
The air supply may be erratic. Verify the air pressure is in the
proper operational range for the rejector.
3.
Check to see if the cylinder is binding by shutting of the air
pressure to the rejector and moving the rejector in and out by
hand. If it is binding, contact your Service Department.
4.
Check the cable between the rejector and the inspection units
for broken or frayed wires. If damaged, contact your Service
Department.
5.
Pass reject test container through the inspector and observe the
time delay synchronization. The rejector pad's centerline
should contact the container’s centerline at the point of impact.
If not, contact your Service Department.
6.
The rejector Pulse Width function may need adjustment.
Contact IDC Customer Support for assistance.
Industrial Dynamics Company, Ltd. Document 40274-0600
Содержание ft-70
Страница 1: ...FT 70 and FT 75 Operation Guide 40274 0600...
Страница 2: ...FT 70 and FT 75 Operation Guide Document 40274 0600 Fill Level Inspectors...
Страница 13: ...FT 70 75 Fill Level Inspectors Operator s Guide XII Industrial Dynamics Company Ltd Document 40274 0600...
Страница 15: ...FT 70 75 Fill Level Inspectors Operator s Guide 1 2 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 21: ...FT 70 75 Fill Level Inspectors Operator s Guide 1 8 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 23: ...FT 70 75 Fill Level Inspectors Operator s Guide 2 2 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 45: ...FT 70 75 Fill Level Inspectors Operator s Guide 2 24 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 47: ...FT 70 75 Fill Level Inspectors Operator s Guide 3 2 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 61: ...FT 70 75 Fill Level Inspectors Operator s Guide 3 16 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 79: ...FT 70 75 Fill Level Inspectors Operator s Guide 5 2 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 85: ...FT 70 75 Fill Level Inspectors Operator s Guide 5 8 Industrial Dynamics Company Ltd Document 40274 0600...