FT-70/75 Fill Level Inspectors Operator’s Guide
3-10
Container Finish Functions Group
High Cap /Bulged Lid Status
Activates or deactivates High Cap detection. High Cap detection is
based on the difference between the height of the container with a
properly seated cap and height of the container with an
improperly seated cap.
Missing Cap/Missing Lid Status
Activates or deactivates missing cap detection. Missing Cap
detection utilizes proximity and optical sensors to detect the
presence or absence of the cap.
Smashed Bottle Status
Activates or deactivates Smashed Bottle Detection.
Diameter Missing Cap Status
Activates or deactivates Diameter Missing Cap detection.
Diameter Missing Cap detection is based on the difference
between the diameter of the container without a cap and diameter
of the container with a cap.
External Reject Status
Activates or deactivates the External Reject function. When
activated the FT-70/75 will accept the reject signal from an outside
inspection source and activate the rejector.
Down Container Status
Activates or deactivates the Down Container detection function for
cans of bottles.
Dud Status
Activates or deactivates the Dud Container detection function.
Dud Detection applies only to cans.
Missing Front/Back Status
Activates or deactivates inspection of front and back label pairs.
Label Detection applies only to bottles.
Industrial Dynamics Company, Ltd. Document 40274-0600
Содержание ft-70
Страница 1: ...FT 70 and FT 75 Operation Guide 40274 0600...
Страница 2: ...FT 70 and FT 75 Operation Guide Document 40274 0600 Fill Level Inspectors...
Страница 13: ...FT 70 75 Fill Level Inspectors Operator s Guide XII Industrial Dynamics Company Ltd Document 40274 0600...
Страница 15: ...FT 70 75 Fill Level Inspectors Operator s Guide 1 2 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 21: ...FT 70 75 Fill Level Inspectors Operator s Guide 1 8 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 23: ...FT 70 75 Fill Level Inspectors Operator s Guide 2 2 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 45: ...FT 70 75 Fill Level Inspectors Operator s Guide 2 24 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 47: ...FT 70 75 Fill Level Inspectors Operator s Guide 3 2 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 61: ...FT 70 75 Fill Level Inspectors Operator s Guide 3 16 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 79: ...FT 70 75 Fill Level Inspectors Operator s Guide 5 2 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 85: ...FT 70 75 Fill Level Inspectors Operator s Guide 5 8 Industrial Dynamics Company Ltd Document 40274 0600...