![Filtec FT-50c Скачать руководство пользователя страница 216](http://html1.mh-extra.com/html/filtec/ft-50c/ft-50c_service-and-technical-reference-manual_2288783216.webp)
Chapter 8: Diagnostic and Repair Procedures
8-25
Quick Reference Troubleshooting Guide
Possible Cause
Corrective Action
Containers are not rejected.
Rejector is not being
energized by inspection unit.
Is the inspector detecting any rejects? Pass a
reject test can through the Inspection
System. With the reject switch set to ON, the
rejector should fire and the Reject LED on the
processor card should flash.
Insufficient or no compressed
air.
Open valve to air supply and adjust regulator
air pressure to 65 psi.
Air lines contaminated or
blocked.
Check all air lines to be sure they are free
from contamination and that air passes
through them freely.
Air pressure incorrect.
Adjust pressure to setting established during
calibration procedure.
Rejector assembly has
malfunctioned.
Inspect the rejector arm as described in the
Routine Preventative Maintenance
procedures
Containers improperly
positioned on the conveyor.
Review the Installation section for proper
installation.
All containers are rejected.
The fill level calibration is
incorrect and all containers
are registering as rejects.
Repeat the Fill Level Calibration Procedure to
establish the correct fill level inspection
parameters.
continued on next page
Industrial Dynamics Company, Ltd.
Document 40255-0600
Содержание FT-50c
Страница 1: ...FT 50c Service and Technical Reference Manual 40255 0600 ...
Страница 2: ...FT 50c Fill Level Inspector Service and Technical Reference Manual Document 40255 0600 ...
Страница 13: ...FT 50 Fill Level Inspector Service Manual XII Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 19: ...FT 50 Fill Level Inspector Service Manual XVIII Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 21: ...FT 50 Fill Level Inspector Service Manual 1 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 33: ...FT 50 Fill Level Inspector Service Manual 1 14 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 35: ...FT 50 Fill Level Inspector Service Manual 2 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 39: ...FT 50 Fill Level Inspector Service Manual 2 6 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 41: ...FT 50 Fill Level Inspector Service Manual 3 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 71: ...FT 50 Fill Level Inspector Service Manual 4 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 99: ...FT 50 Fill Level Inspector Service Manual 5 4 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 139: ...FT 50 Fill Level Inspector Service Manual 5 44 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 141: ...FT 50 Fill Level Inspector Service Manual 6 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 185: ...FT 50 Fill Level Inspector Service Manual 7 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 191: ...FT 50 Fill Level Inspector Service Manual 7 8 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 219: ...FT 50 Fill Level Inspector Service Manual 9 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 227: ...FT 50 Fill Level Inspector Service Manual 10 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 237: ...FT 50 Fill Level Inspector Service Manual 10 12 Industrial Dynamics Company Ltd Document 40255 0600 ...