Line Speed (cph)
The speed of the production line measured by cph (containers per
hour). The measurement is the number containers that intercept
the FT-50’s trigger beam in 60 minutes. To calculate cph use the
following formula:
System Display
Switches the system between the Operate Mode and the Calibrate
Mode. The Operate Mode is the normal operating mode for the
machine and allows access only to those functions required for
production operation. The Calibrate Mode grants the operator
complete access to all system functions, including configuration
and container programming functions.
When the password function is activated, the password must be
entered before the user is granted access to the Calibrate Mode.
When in Calibrate Mode, if the FT-50 is idle (no keys are pressed)
for 30 minutes, the system automatically returns to the Operate
Mode. For more information, see
Selecting the FT-50’s Operating
Mode.
To switch operating modes:
1.
Press Key 5 until SYSTEM DISPLAY appears.
2.
Press the Arrow Key to select either the Operate or Calibrate
mode. If the Password Protect function is enabled, you are
required to enter the password before you can access the
Calibrate mode.
Conveyor Drive Sprocket
The number of teeth on the sprocket that is physically contacting
the conveyor chain. This is the primary value that is used to
determine the encoder calibration.
Serial Data ID Number
The FT-50’s serial port identification number. This function applies
only to units equipped with either the IDC or Modbus serial
communications options. For further information refer to the
Serial Communication Manual
.
cpm
60
×
cph
=
Industrial Dynamics Company, Ltd. Document 40255-0600
Содержание FT-50c
Страница 1: ...FT 50c Service and Technical Reference Manual 40255 0600 ...
Страница 2: ...FT 50c Fill Level Inspector Service and Technical Reference Manual Document 40255 0600 ...
Страница 13: ...FT 50 Fill Level Inspector Service Manual XII Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 19: ...FT 50 Fill Level Inspector Service Manual XVIII Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 21: ...FT 50 Fill Level Inspector Service Manual 1 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 33: ...FT 50 Fill Level Inspector Service Manual 1 14 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 35: ...FT 50 Fill Level Inspector Service Manual 2 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 39: ...FT 50 Fill Level Inspector Service Manual 2 6 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 41: ...FT 50 Fill Level Inspector Service Manual 3 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 71: ...FT 50 Fill Level Inspector Service Manual 4 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 99: ...FT 50 Fill Level Inspector Service Manual 5 4 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 139: ...FT 50 Fill Level Inspector Service Manual 5 44 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 141: ...FT 50 Fill Level Inspector Service Manual 6 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 185: ...FT 50 Fill Level Inspector Service Manual 7 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 191: ...FT 50 Fill Level Inspector Service Manual 7 8 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 219: ...FT 50 Fill Level Inspector Service Manual 9 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 227: ...FT 50 Fill Level Inspector Service Manual 10 2 Industrial Dynamics Company Ltd Document 40255 0600 ...
Страница 237: ...FT 50 Fill Level Inspector Service Manual 10 12 Industrial Dynamics Company Ltd Document 40255 0600 ...