background image

 

This document is subject to Fike’s full disclaimer at 

http://www.fike.com/disclaimer

Fike reserves the right to change product designs or specifications without obligation and without further notice. 

Page 1 of 2 

Doc. P/N 06-780 

Rev. 1 / June, 2019 

 

Quick Start Guide 

VIDEO ANALYTICS CORPORATION 

ONVIF Camera Setup 

ONVIF Camera setting options may vary slightly; therefore there is no way for us to provide you with exact step by 
step instructions.  This is simply a guide/checklist you can choose to go through to insure our Fike Video Analytics

®

 

Server can communicate with your ONVIF camera. 

First: 

1.

 

Make sure your camera's IP address is compatible with your network.  If it is not, change it.

 

2.

 

Using your ONVIF camera manual, make sure your camera is setup for ONVIF.

 

3.

 

Connect camera to the network and see if you are able to discover the camera using the Fike Video 
Analytics video management software.

 

 If you can discover the camera and add it to the video 

management software, you're done.  If you cannot discover the camera please use the checklist below to 
troubleshoot.

 

Troubleshooting: 

1.

 

Enter the camera's default IP Address into a web browser to access camera's settings 

2.

 

You may need to update camera firmware software.  Determine what version is loaded onto the camera.  
Then go to ONVIF's website, 

http://www.onvif.org/ConformantProducts 

 Go to 'Find A Product' Click on 

the camera's manufacturer and find your model camera.  It will show you what minimum software version 
is required for ONVIF.  

3.

 

You can choose to add/change passwords for cameras and if allowed set it up with Administrator rights.  It 
is ideal to have all the cameras on your network setup with the same login username/password e.g. 
(admin/axonx) so you only need to enter it once into the video management software.  If every camera is 
setup with a different login, you will need to enter every camera's login username/password in the video 
management software in order to add them to the system. 

4.

 

Make sure the time zone on the camera matches the same time zone on the NVR or Synchronize the 
camera with computer (NVR) time. Mismatched date time settings may result in authentication errors.  

5.

 

Make sure all relevant ONVIF options in camera configuration as described in camera manufacturer’s 
manuals are turned on 

6.

 

Change IP Address to desired new address (dhcp or static) 

7.

 

Restart camera to except the new IP address 

 

For further assistance, please call Fike Video Analytics Corporation technical support at (844‐345‐3843). 

 