 Quick Start

1.  Power on your SVG3 by holding the 

 button for 1 second. 

2.  Connect to system directly to an 

unused service port, a Schrader core 

removal tool (SCRT), or via hoses.

3.  View vacuum in microns of mercury 

on the top line and rate of change 

(±microns per minute) on the bot-

tom line.

 

Certifications

  

     

C-Tick (N22675)

  

CE 

 

  

WEEE

     

RoHS Compliant

Description

Proper evacuation of any system 

exposed to atmosphere is critical to 

ensure efficient operation and the 

SVG3 is the right tool to help HVACR 

professionals verify they reach proper 

vacuum levels.  See your vacuum 

measurement clearly and easily with 

the newly designed easy-view hook 

and backlight. SVG3 is built for field 

use with its ruggedized rubber case. 

Reducing connections mini-

mizes leaks, so the SVG3 has 

a  female  1/4" flare fitting with 

schrader depressor so you can  

connect it directly to a service port or 

your valve core removal tool.  

Be alerted when you've reached 

your desired vacuum levels with built 

in Hi and Lo Alarm functions. Check for 

leaks with rate indication in microns 

per minute. The HVACR professional 

can do more with confidence that he 

is doing the job right the first time. 

Display

Top Line:  Live Vacuum Measurement  

   

    in Microns of Mercury (Hg)

Bottom Line:  Rate of Micron Change  

   

    or Alarm Stopwatch

     

Auto Power Off Enabled 

     

Battery Life

     

Alarm Set Mode

     

Low Alarm Mode

     

High Alarm Mode

     

Rate of Micron Change 

     

(±Microns Per Minute) 

Fieldpiece

Easy View  

Vacuum Gauge

 

OPERATOR'S MANUAL

Model SVG3

 

Controls

   

Hold 1 second to power SVG3 on/ off.  Press  

 

<1 second to toggle backlight.

  

   

Press to activate Alarm Lo, Alarm Hi, and  

 

return to real time mode. Hold 1 second to  

 

enter or exit Alarm Set mode.

   

 

  

   

Lock in selected digit and move to next in  

 

Alarm Set Mode.

  

 

 

   

Increase or decrease blinking digit in  

 

Alarm Set Mode. Toggle to display  

 

stopwatch or rate of change when an  

 

alarm is activated in real time mode.

  

  

 

 

 

BACKLIGHT NOTE:  The backlight timer is automatically 

extended for 1 min when any button is pressed. A short 

press of   toggles backlight on and off.

Specifications

General

Operating temperature:  32°F (0°C) to 122°F (50°C) at 

<75%RH

Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 

to 80% RH (with battery removed)

Temperature coefficient: 0.1 x (specified accuracy)/°C 

(<18°C or >28°C)

Over range:

  

"OL" is displayed

Power: 4 x AAA batteries, NEDA 24A, JIS UM4, IEC R03 

Auto power off:

 

after 15 minutes of readings more 

than 10,000 microns if APO is active.

Battery life: 40 hours standard use (alkaline) without 

backlight use.

Low battery indication:   

 is displayed when the 

battery voltage drops below the operating level.

Vacuum Pressure

Units of measure:  microns (µm) of mercury

Connector type:  Standard 1/4" female flare fitting. "T" 

fitting included ( 3 male flare ports)

Range:  0 to 9999 microns of mercury

Accuracy:  ±(5% of r 5 microns), 50 to 1000 

microns

Resolution:  1 micron (50 to 2000 microns), 250 

microns (2001 to 5000 microns), 500 microns (5001 

to 8000 microns), 1000 microns (8001 to 9999 

microns)

Rate:  Microns per minute

Refresh rate:  0.5 seconds

Atmospheric pressure:  "OL" will be displayed

Maximum overload pressure:  500 psig

How to Use

Normal Mode

M e a s u re   d e e p   v a c u u m s   t o 

monitor your system evacua-

tions. Deep vacuums help remove  

non-condensable gases that can 

cause problems in a system. 

There are many ways to connect to 

the system, Fieldpiece recommends 

using a SCRT and the shortest vacuum 

rated hoses possible. Fewer connec-

tions reduce the potential for leaks.

1.   Connect to system. Techs typically prefer connect-

ing to the Schrader Core Removal Tool (SCRT) or an 

unused service port. 

2.   Hold   for 1 second to power ON the SVG3.

3.   The top display shows the vacuum in microns of 

mercury. 

4.   The bottom display shows how fast the measure-

ment is increasing or decreasing (± microns  of 

mercury per minute).  

Low and High Alarms

Be alerted when you've reached your 

desired vacuum levels. Work on other 
tasks at the jobsite and let SVG3 alert 
you when the system is ready. 

Activate the low alarm (default 500 

microns) to alert when the vacuum has 
dropped to your desired micron level.

Activate the high alarm (default 1000 

microns) to see how long it takes the 
system to stabilize after the vacuum 
pump has been isolated. If the system 
does not stabilize over time, you may 
have a leak in the system or your con-
nections.

The stopwatch will start when an 

alarm is activated. It will restart when 
the low alarm has been reached to show 
how long you've pulled a vacuum after 
reaching your desired micron level. The 
stopwatch will stop when the high alarm 
has been reached to show how long it 
took to rise to your high alarm value.

When an alarm is activated the UP or 

DOWN ARROW toggles the stopwatch 
and rate of change (± microns per min-
ute) display. 

How to Activate the Alarms

1.   Press ALARM to activate low alarm. 

2.   Press ALARM again to deactivate low alarm and 

activate high alarm.

3.   Press ALARM again to deactivate high alarm and 

return to real time mode. 

How to Set the Alarms

The default low (500 microns) and 

high (1000 microns) alarm values can 

easily be set to whatever you want.

1.   Hold ALARM for 1 second to enter Alarm Set Mode. 

The first digit of LO alarm will blink. 

2.   Use ARROWS to change the blinking number. Press 

ENTER to lock in a digit and move to the next digit. 

Repeat for all LO alarm digits.

3. When LO alarm is complete, the first digit of HI alarm 

will blink. Use ARROWS to change the blinking 

number. Press ENTER to lock in a digit and move to 

the next digit. Repeat for all HI alarm digits. 

4. When all digits of HI alarm are locked in you will 

automatically exit Alarm Set Mode and your 

customized alarm values will be saved.

Note:  Anytime while in Alarm Set Mode, you can press 

ALARM to toggle between alarm HI set and alarm 

LO set. Hold ALARM to exit Alarm Set Mode and 

save at any time.

Note:  "Err" will show if you try to set the HI alarm 

lower than the LO alarm, or the LO alarm higher 
than the HI alarm.

Vacuum Tips

Follow all manufacturer's evacu-

ation procedures over those in this 

manual in regards to specifications on 

how to evacuate systems. To achieve 

a deep vacuum efficiently Fieldpiece 

recommends the following practices.

1. Remove Schrader cores and core depressors from 

the service ports using a valve core removal tool 

(purchased separately). 

2. Use the shortest vacuum rated hoses with the 

largest diameter available.

3. Inspect rubber seals at both ends of your hoses for 

damage that may result in leakage.

4. Avoid using hoses with low loss fittings when 

evacuating a system.

5. Avoid over-tightening the female flare fitting of 

the SVG3. Over-tightening may cause the rubber 

gasket to wear more quickly and create leaks. It is 

not necessary to over tighten SVG3 to the extreme 

to create a good seal.

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

(tool not included)

Recommended 

Setup

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

To

Pump

To

Service

Port

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

Hose to

Removal 

Tool

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

Other Common

Setups

Отзывы: